Secondary Current is the current which is flows in the secondary winding of transformer. Check FAQs
I2=Eself(2)XL2
I2 - Secondary Current?Eself(2) - Self Induced EMF in Secondary?XL2 - Secondary Leakage Reactance?

Secondary Current given Secondary Leakage Reactance Example

With values
With units
Only example

Here is how the Secondary Current given Secondary Leakage Reactance equation looks like with Values.

Here is how the Secondary Current given Secondary Leakage Reactance equation looks like with Units.

Here is how the Secondary Current given Secondary Leakage Reactance equation looks like.

10.5263Edit=10Edit0.95Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Secondary Current given Secondary Leakage Reactance

Secondary Current given Secondary Leakage Reactance Solution

Follow our step by step solution on how to calculate Secondary Current given Secondary Leakage Reactance?

FIRST Step Consider the formula
I2=Eself(2)XL2
Next Step Substitute values of Variables
I2=10V0.95Ω
Next Step Prepare to Evaluate
I2=100.95
Next Step Evaluate
I2=10.5263157894737A
LAST Step Rounding Answer
I2=10.5263A

Secondary Current given Secondary Leakage Reactance Formula Elements

Variables
Secondary Current
Secondary Current is the current which is flows in the secondary winding of transformer.
Symbol: I2
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Self Induced EMF in Secondary
Self induced emf in secondary is the electromagnetic force induced in the secondary winding or coil when the current in the coil or winding changes.
Symbol: Eself(2)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Secondary Leakage Reactance
Secondary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding.
Symbol: XL2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.

Other Formulas to find Secondary Current

​Go Secondary Current using Secondary Parameters
I2=E2-V2Z2
​Go Secondary Current given Voltage Transformation Ratio
I2=I1K

Other formulas in Current category

​Go Primary Current given Primary Leakage Reactance
I1=Eself(1)XL1
​Go Primary Current using Primary Parameters
I1=V1-E1Z1
​Go Primary Current given Voltage Transformation Ratio
I1=I2K

How to Evaluate Secondary Current given Secondary Leakage Reactance?

Secondary Current given Secondary Leakage Reactance evaluator uses Secondary Current = Self Induced EMF in Secondary/Secondary Leakage Reactance to evaluate the Secondary Current, The Secondary Current given Secondary Leakage Reactance formula is defined as the current that flows in secondary winding when secondary leakage reactance is given. Secondary Current is denoted by I2 symbol.

How to evaluate Secondary Current given Secondary Leakage Reactance using this online evaluator? To use this online evaluator for Secondary Current given Secondary Leakage Reactance, enter Self Induced EMF in Secondary (Eself(2)) & Secondary Leakage Reactance (XL2) and hit the calculate button.

FAQs on Secondary Current given Secondary Leakage Reactance

What is the formula to find Secondary Current given Secondary Leakage Reactance?
The formula of Secondary Current given Secondary Leakage Reactance is expressed as Secondary Current = Self Induced EMF in Secondary/Secondary Leakage Reactance. Here is an example- 10.52632 = 10/0.95.
How to calculate Secondary Current given Secondary Leakage Reactance?
With Self Induced EMF in Secondary (Eself(2)) & Secondary Leakage Reactance (XL2) we can find Secondary Current given Secondary Leakage Reactance using the formula - Secondary Current = Self Induced EMF in Secondary/Secondary Leakage Reactance.
What are the other ways to Calculate Secondary Current?
Here are the different ways to Calculate Secondary Current-
  • Secondary Current=(EMF Induced in Secondary-Secondary Voltage)/Impedance of SecondaryOpenImg
  • Secondary Current=Primary Current/Transformation RatioOpenImg
Can the Secondary Current given Secondary Leakage Reactance be negative?
Yes, the Secondary Current given Secondary Leakage Reactance, measured in Electric Current can be negative.
Which unit is used to measure Secondary Current given Secondary Leakage Reactance?
Secondary Current given Secondary Leakage Reactance is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Secondary Current given Secondary Leakage Reactance can be measured.