Saturated Temperature using Antoine Equation Formula

Fx Copy
LaTeX Copy
Saturated temperature is the temperature at which a given liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given pressure. Check FAQs
Tsat=(BA-ln(P))-C
Tsat - Saturated Temperature?B - Antoine Equation Constant, B?A - Antoine Equation Constant, A?P - Pressure?C - Antoine Equation Constant, C?

Saturated Temperature using Antoine Equation Example

With values
With units
Only example

Here is how the Saturated Temperature using Antoine Equation equation looks like with Values.

Here is how the Saturated Temperature using Antoine Equation equation looks like with Units.

Here is how the Saturated Temperature using Antoine Equation equation looks like.

-25.0096Edit=(2100Edit15Edit-ln(38.4Edit))-210Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Thermodynamics » fx Saturated Temperature using Antoine Equation

Saturated Temperature using Antoine Equation Solution

Follow our step by step solution on how to calculate Saturated Temperature using Antoine Equation?

FIRST Step Consider the formula
Tsat=(BA-ln(P))-C
Next Step Substitute values of Variables
Tsat=(2100K15-ln(38.4Pa))-210K
Next Step Prepare to Evaluate
Tsat=(210015-ln(38.4))-210
Next Step Evaluate
Tsat=-25.0096344722306K
LAST Step Rounding Answer
Tsat=-25.0096K

Saturated Temperature using Antoine Equation Formula Elements

Variables
Functions
Saturated Temperature
Saturated temperature is the temperature at which a given liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given pressure.
Symbol: Tsat
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Antoine Equation Constant, B
Antoine equation constant, B is one of the parameters of Antoine equation which has a unit of temperature.
Symbol: B
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Antoine Equation Constant, A
Antoine equation constant, A is component specific parameter.
Symbol: A
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Pressure
Pressure is the force applied perpendicular to the surface of an object per unit area over which that force is distributed.
Symbol: P
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.
Antoine Equation Constant, C
Antoine equation constant, C is one of the parameters of Antoine equation which has a unit of temperature.
Symbol: C
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
ln
The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function.
Syntax: ln(Number)

Other formulas in Antoine Equation category

​Go Atmospheric Pressure of Water at Boiling Temperature using Antoine Equation
Patm=108.07131-(1730.63233.426+bp)
​Go Boiling Temperature of Water for Atmospheric Pressure using Antoine Equation
bp=(1730.638.07131-log10(Patm))-233.426
​Go Pressure using Saturated Temperature in Antoine Equation
P=exp(A-(BTsat+C))
​Go Saturated Pressure using Antoine Equation
Psat=exp(A-(BT+C))

How to Evaluate Saturated Temperature using Antoine Equation?

Saturated Temperature using Antoine Equation evaluator uses Saturated Temperature = (Antoine Equation Constant, B/(Antoine Equation Constant, A-ln(Pressure)))-Antoine Equation Constant, C to evaluate the Saturated Temperature, The Saturated Temperature using Antoine Equation formula is defined as the function of the Antoine equation constants A, B and C and pressure. Saturated Temperature is denoted by Tsat symbol.

How to evaluate Saturated Temperature using Antoine Equation using this online evaluator? To use this online evaluator for Saturated Temperature using Antoine Equation, enter Antoine Equation Constant, B (B), Antoine Equation Constant, A (A), Pressure (P) & Antoine Equation Constant, C (C) and hit the calculate button.

FAQs on Saturated Temperature using Antoine Equation

What is the formula to find Saturated Temperature using Antoine Equation?
The formula of Saturated Temperature using Antoine Equation is expressed as Saturated Temperature = (Antoine Equation Constant, B/(Antoine Equation Constant, A-ln(Pressure)))-Antoine Equation Constant, C. Here is an example- -25.009634 = (2100/(15-ln(38.4)))-210.
How to calculate Saturated Temperature using Antoine Equation?
With Antoine Equation Constant, B (B), Antoine Equation Constant, A (A), Pressure (P) & Antoine Equation Constant, C (C) we can find Saturated Temperature using Antoine Equation using the formula - Saturated Temperature = (Antoine Equation Constant, B/(Antoine Equation Constant, A-ln(Pressure)))-Antoine Equation Constant, C. This formula also uses Natural Logarithm (ln) function(s).
Can the Saturated Temperature using Antoine Equation be negative?
Yes, the Saturated Temperature using Antoine Equation, measured in Temperature can be negative.
Which unit is used to measure Saturated Temperature using Antoine Equation?
Saturated Temperature using Antoine Equation is usually measured using the Kelvin[K] for Temperature. Celsius[K], Fahrenheit[K], Rankine[K] are the few other units in which Saturated Temperature using Antoine Equation can be measured.
Copied!