Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species Formula

Fx Copy
LaTeX Copy
Saturated pressure is the pressure at which a given liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given temperature. Check FAQs
Psat=flϕsatP.F.
Psat - Saturated Pressure?fl - Fugacity of Liquid Phase Species?ϕsat - Saturated Fugacity Coefficient of Species?P.F. - Poynting Factor?

Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species Example

With values
With units
Only example

Here is how the Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species equation looks like with Values.

Here is how the Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species equation looks like with Units.

Here is how the Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species equation looks like.

1.3077Edit=17Edit0.13Edit100Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Thermodynamics » fx Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species

Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species Solution

Follow our step by step solution on how to calculate Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species?

FIRST Step Consider the formula
Psat=flϕsatP.F.
Next Step Substitute values of Variables
Psat=17Pa0.13100
Next Step Prepare to Evaluate
Psat=170.13100
Next Step Evaluate
Psat=1.30769230769231Pa
LAST Step Rounding Answer
Psat=1.3077Pa

Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species Formula Elements

Variables
Saturated Pressure
Saturated pressure is the pressure at which a given liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given temperature.
Symbol: Psat
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.
Fugacity of Liquid Phase Species
Fugacity of Liquid Phase Species is denoted by fl symbol.
Symbol: fl
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.
Saturated Fugacity Coefficient of Species
Saturated Fugacity Coefficient of Species is the ratio of the saturated fugacity of a species to the saturated pressure of a species.
Symbol: ϕsat
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Poynting Factor
Poynting Factor can be stated as the change in fugacity as the pressure goes from the saturated pressure to pressure at a constant temperature.
Symbol: P.F.
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Fugacity and Fugacity Coefficient category

​Go Poynting Factor
P.F.=exp(-Vl(P-Psat)[R]T)
​Go Fugacity of Liq. Phase Species using Poynting Factor Correlation
fl=ϕsatPsatexp(Vl(P-Psat)[R]T)
​Go Fugacity of Liq. Phase Species using Poynting Factor
fl=ϕsatPsatP.F.
​Go Saturated Fugacity Coeff. using Poynting Factor Correlation and Fugacity of Liq. Phase Species
ϕsat=flPsatexp(-Vl(P-Psat)[R]T)

How to Evaluate Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species?

Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species evaluator uses Saturated Pressure = Fugacity of Liquid Phase Species/(Saturated Fugacity Coefficient of Species*Poynting Factor) to evaluate the Saturated Pressure, The Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species formula is defined as the function of fugacity of the liquid phase of a species, saturated fugacity coefficient of a species and poynting factor. Saturated Pressure is denoted by Psat symbol.

How to evaluate Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species using this online evaluator? To use this online evaluator for Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species, enter Fugacity of Liquid Phase Species (fl), Saturated Fugacity Coefficient of Species sat) & Poynting Factor (P.F.) and hit the calculate button.

FAQs on Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species

What is the formula to find Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species?
The formula of Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species is expressed as Saturated Pressure = Fugacity of Liquid Phase Species/(Saturated Fugacity Coefficient of Species*Poynting Factor). Here is an example- 1.307692 = 17/(0.13*100).
How to calculate Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species?
With Fugacity of Liquid Phase Species (fl), Saturated Fugacity Coefficient of Species sat) & Poynting Factor (P.F.) we can find Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species using the formula - Saturated Pressure = Fugacity of Liquid Phase Species/(Saturated Fugacity Coefficient of Species*Poynting Factor).
Can the Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species be negative?
Yes, the Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species, measured in Pressure can be negative.
Which unit is used to measure Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species?
Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species is usually measured using the Pascal[Pa] for Pressure. Kilopascal[Pa], Bar[Pa], Pound Per Square Inch[Pa] are the few other units in which Saturated Pressure using Poynting Factor and Fugacity of Liq. Phase Species can be measured.
Copied!