Saturated Pressure using Modified Raoult's Law in VLE Formula

Fx Copy
LaTeX Copy
Saturated pressure is the pressure at which a given liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given temperature. Check FAQs
Psat =yGasPTxLiquidγRaoults
Psat - Saturated pressure?yGas - Mole Fraction of Component in Vapor Phase?PT - Total Pressure of Gas?xLiquid - Mole Fraction of Component in Liquid Phase?γRaoults - Activity Coefficient in Raoults Law?

Saturated Pressure using Modified Raoult's Law in VLE Example

With values
With units
Only example

Here is how the Saturated Pressure using Modified Raoult's Law in VLE equation looks like with Values.

Here is how the Saturated Pressure using Modified Raoult's Law in VLE equation looks like with Units.

Here is how the Saturated Pressure using Modified Raoult's Law in VLE equation looks like.

66732.0261Edit=0.3Edit102100Edit0.51Edit0.9Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Thermodynamics » fx Saturated Pressure using Modified Raoult's Law in VLE

Saturated Pressure using Modified Raoult's Law in VLE Solution

Follow our step by step solution on how to calculate Saturated Pressure using Modified Raoult's Law in VLE?

FIRST Step Consider the formula
Psat =yGasPTxLiquidγRaoults
Next Step Substitute values of Variables
Psat =0.3102100Pa0.510.9
Next Step Prepare to Evaluate
Psat =0.31021000.510.9
Next Step Evaluate
Psat =66732.0261437908Pa
LAST Step Rounding Answer
Psat =66732.0261Pa

Saturated Pressure using Modified Raoult's Law in VLE Formula Elements

Variables
Saturated pressure
Saturated pressure is the pressure at which a given liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given temperature.
Symbol: Psat
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.
Mole Fraction of Component in Vapor Phase
The Mole Fraction of Component in Vapor Phase can be defined as the ratio of the number of moles a component to the total number of moles of components present in the vapor phase.
Symbol: yGas
Measurement: NAUnit: Unitless
Note: Value should be between 0 to 1.
Total Pressure of Gas
Total pressure of Gas is the sum of all the forces that the gas molecules exert on the walls of their container.
Symbol: PT
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.
Mole Fraction of Component in Liquid Phase
The Mole Fraction of Component in Liquid Phase can be defined as the ratio of the number of moles a component to the total number of moles of components present in the liquid phase.
Symbol: xLiquid
Measurement: NAUnit: Unitless
Note: Value should be between 0 to 1.
Activity Coefficient in Raoults Law
Activity Coefficient in Raoults Law is a factor used in thermodynamics to account for deviations from ideal behaviour in a mixture of chemical substances.
Symbol: γRaoults
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Raoult’s Law, Modified Raoult’s Law, and Henry’s Law in VLE category

​Go Activity Coefficient using Modified Raoult's Law in VLE
γRaoults=yGasPTxLiquidPsat
​Go Liquid Phase Mole Fraction using Modified Raoult's Law in VLE
xLiquid=yGasPTγRaoultsPsat
​Go Vapour Phase Mole Fraction using Modified Raoult's Law in VLE
yGas=xLiquidγRaoultsPsat PT
​Go Total Pressure using Modified Raoult's Law in VLE
PT=xLiquidγRaoultsPsat yGas

How to Evaluate Saturated Pressure using Modified Raoult's Law in VLE?

Saturated Pressure using Modified Raoult's Law in VLE evaluator uses Saturated pressure = (Mole Fraction of Component in Vapor Phase*Total Pressure of Gas)/(Mole Fraction of Component in Liquid Phase*Activity Coefficient in Raoults Law) to evaluate the Saturated pressure, The Saturated Pressure using Modified Raoult's Law in VLE formula is defined as the ratio of the product of the vapour phase mole fraction and the total pressure to the product of the liquid phase mole fraction and the activity coefficient of mixture or solution. Saturated pressure is denoted by Psat symbol.

How to evaluate Saturated Pressure using Modified Raoult's Law in VLE using this online evaluator? To use this online evaluator for Saturated Pressure using Modified Raoult's Law in VLE, enter Mole Fraction of Component in Vapor Phase (yGas), Total Pressure of Gas (PT), Mole Fraction of Component in Liquid Phase (xLiquid) & Activity Coefficient in Raoults Law Raoults) and hit the calculate button.

FAQs on Saturated Pressure using Modified Raoult's Law in VLE

What is the formula to find Saturated Pressure using Modified Raoult's Law in VLE?
The formula of Saturated Pressure using Modified Raoult's Law in VLE is expressed as Saturated pressure = (Mole Fraction of Component in Vapor Phase*Total Pressure of Gas)/(Mole Fraction of Component in Liquid Phase*Activity Coefficient in Raoults Law). Here is an example- 196944.4 = (0.3*102100)/(0.51*0.9).
How to calculate Saturated Pressure using Modified Raoult's Law in VLE?
With Mole Fraction of Component in Vapor Phase (yGas), Total Pressure of Gas (PT), Mole Fraction of Component in Liquid Phase (xLiquid) & Activity Coefficient in Raoults Law Raoults) we can find Saturated Pressure using Modified Raoult's Law in VLE using the formula - Saturated pressure = (Mole Fraction of Component in Vapor Phase*Total Pressure of Gas)/(Mole Fraction of Component in Liquid Phase*Activity Coefficient in Raoults Law).
Can the Saturated Pressure using Modified Raoult's Law in VLE be negative?
Yes, the Saturated Pressure using Modified Raoult's Law in VLE, measured in Pressure can be negative.
Which unit is used to measure Saturated Pressure using Modified Raoult's Law in VLE?
Saturated Pressure using Modified Raoult's Law in VLE is usually measured using the Pascal[Pa] for Pressure. Kilopascal[Pa], Bar[Pa], Pound Per Square Inch[Pa] are the few other units in which Saturated Pressure using Modified Raoult's Law in VLE can be measured.
Copied!