Sanitary Sewer System Flow Rate Formula

Fx Copy
LaTeX Copy
Sanitary System Sewer Flow Rate is the measure of the volume of wastewater flowing through a sewer system per unit of time. Check FAQs
SSfr=APdQ
SSfr - Sanitary System Sewer Flow Rate?A - Cross Sectional Area?Pd - Population Density of Area?Q - Discharge?

Sanitary Sewer System Flow Rate Example

With values
With units
Only example

Here is how the Sanitary Sewer System Flow Rate equation looks like with Values.

Here is how the Sanitary Sewer System Flow Rate equation looks like with Units.

Here is how the Sanitary Sewer System Flow Rate equation looks like.

1.1999Edit=50Edit23.76Edit1.01Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Sanitary Sewer System Flow Rate

Sanitary Sewer System Flow Rate Solution

Follow our step by step solution on how to calculate Sanitary Sewer System Flow Rate?

FIRST Step Consider the formula
SSfr=APdQ
Next Step Substitute values of Variables
SSfr=5023.76Hundred/km²1.01m³/s
Next Step Convert Units
SSfr=502.4E-5Hundred/m²1.01m³/s
Next Step Prepare to Evaluate
SSfr=502.4E-51.01
Next Step Evaluate
SSfr=0.00119988m³/s
Next Step Convert to Output's Unit
SSfr=1.19988L/s
LAST Step Rounding Answer
SSfr=1.1999L/s

Sanitary Sewer System Flow Rate Formula Elements

Variables
Sanitary System Sewer Flow Rate
Sanitary System Sewer Flow Rate is the measure of the volume of wastewater flowing through a sewer system per unit of time.
Symbol: SSfr
Measurement: Volumetric Flow RateUnit: L/s
Note: Value should be greater than 0.
Cross Sectional Area
Cross Sectional Area is typically determined based on the geometry of the pipe or channel through which the wastewater flows.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Population Density of Area
Population Density of Area refers to the measurement of the number of people per unit area in a defined geographical area, typically expressed as the number of individuals per square kilometer.
Symbol: Pd
Measurement: Population DensityUnit: Hundred/km²
Note: Value should be greater than 0.
Discharge
Discharge refers to the volume of wastewater flowing through the sewer system per unit of time. It is usually measured in cubic meters per second (m³/s) or liters per second (L/s).
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.

Other formulas in Sanitary System Sewer Design category

​Go Flow Rate through Pipe using Manning Formula
W=Cf(i)12
​Go Manning's Formula for Conveyance Factor given Flow Rate through Pipe
Cf=Wi
​Go Manning's Formula for Pipe Slope given Flow Rate through Pipe
i=(WCf)2
​Go Population Density given Sanitary Sewer System Flow Rate
Pd=SSfrAQ

How to Evaluate Sanitary Sewer System Flow Rate?

Sanitary Sewer System Flow Rate evaluator uses Sanitary System Sewer Flow Rate = Cross Sectional Area*Population Density of Area*Discharge to evaluate the Sanitary System Sewer Flow Rate, The Sanitary Sewer System Flow Rate formula is defined as the sewer system is designed to collect and transport wastewater from residential, commercial, and industrial sources to treatment facilities, ensuring public health and environmental protection. Sanitary System Sewer Flow Rate is denoted by SSfr symbol.

How to evaluate Sanitary Sewer System Flow Rate using this online evaluator? To use this online evaluator for Sanitary Sewer System Flow Rate, enter Cross Sectional Area (A), Population Density of Area (Pd) & Discharge (Q) and hit the calculate button.

FAQs on Sanitary Sewer System Flow Rate

What is the formula to find Sanitary Sewer System Flow Rate?
The formula of Sanitary Sewer System Flow Rate is expressed as Sanitary System Sewer Flow Rate = Cross Sectional Area*Population Density of Area*Discharge. Here is an example- 1199.88 = 50*2.376E-05*1.01.
How to calculate Sanitary Sewer System Flow Rate?
With Cross Sectional Area (A), Population Density of Area (Pd) & Discharge (Q) we can find Sanitary Sewer System Flow Rate using the formula - Sanitary System Sewer Flow Rate = Cross Sectional Area*Population Density of Area*Discharge.
Can the Sanitary Sewer System Flow Rate be negative?
No, the Sanitary Sewer System Flow Rate, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Sanitary Sewer System Flow Rate?
Sanitary Sewer System Flow Rate is usually measured using the Liter per Second[L/s] for Volumetric Flow Rate. Cubic Meter per Second[L/s], Cubic Meter per Day[L/s], Cubic Meter per Hour[L/s] are the few other units in which Sanitary Sewer System Flow Rate can be measured.
Copied!