Fx Copy
LaTeX Copy
Tensile Load is the stretching force acting on the material and generally results in tensile stress and tensile strain in the specimen. Check FAQs
Pload=σt(p-Drivet)tplate
Pload - Tensile Load?σt - Tensile Stress?p - Pitch of Rivet?Drivet - Rivet Diameter?tplate - Thickness of Plate?

Safe tensile load that plate can withstand Example

With values
With units
Only example

Here is how the Safe tensile load that plate can withstand equation looks like with Values.

Here is how the Safe tensile load that plate can withstand equation looks like with Units.

Here is how the Safe tensile load that plate can withstand equation looks like.

0.0042Edit=0.173Edit(20Edit-18Edit)12Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Strength of Materials » fx Safe tensile load that plate can withstand

Safe tensile load that plate can withstand Solution

Follow our step by step solution on how to calculate Safe tensile load that plate can withstand?

FIRST Step Consider the formula
Pload=σt(p-Drivet)tplate
Next Step Substitute values of Variables
Pload=0.173MPa(20mm-18mm)12mm
Next Step Convert Units
Pload=173000Pa(0.02m-0.018m)0.012m
Next Step Prepare to Evaluate
Pload=173000(0.02-0.018)0.012
Next Step Evaluate
Pload=4.152N
Next Step Convert to Output's Unit
Pload=0.004152kN
LAST Step Rounding Answer
Pload=0.0042kN

Safe tensile load that plate can withstand Formula Elements

Variables
Tensile Load
Tensile Load is the stretching force acting on the material and generally results in tensile stress and tensile strain in the specimen.
Symbol: Pload
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
Tensile Stress
Tensile stress can be defined as the magnitude of force applied along an elastic rod, which is divided by the cross-sectional area of the rod in a direction perpendicular to the applied force.
Symbol: σt
Measurement: PressureUnit: MPa
Note: Value should be greater than 0.
Pitch of Rivet
Pitch of Rivet is defined as the distance between the centers of adjacent rivets that hold together the parts of a built member.
Symbol: p
Measurement: LengthUnit: mm
Note: Value can be positive or negative.
Rivet Diameter
Rivet Diameter is offered from 1/16-inch (1.6 mm) to 3/8-inch (9.5 mm) in diameter (other sizes are considered highly special) and can be up to 8 inches (203 mm) long.
Symbol: Drivet
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Thickness of Plate
The thickness of plate is the state or quality of being thick. The measure of the smallest dimension of a solid figure: a board of two-inch thickness.
Symbol: tplate
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other Formulas to find Tensile Load

​Go Safe tensile load that plate can withstand given area of plate
Pload=σtAb

Other formulas in Failure Due to Tearing of the Plate Between Rivets of a Row category

​Go Safe tensile stress given area of base plate and tensile load
σt=PloadAb
​Go Area of plate for given safe tensile load that plate can withstand
Ab=Ploadσt
​Go Safe tensile stress in plate
σt=Pload(p-Drivet)tplate
​Go Pitch of rivet given safe tensile load that plate can withstand
p=(Ploadσttplate)+Drivet

How to Evaluate Safe tensile load that plate can withstand?

Safe tensile load that plate can withstand evaluator uses Tensile Load = Tensile Stress*(Pitch of Rivet-Rivet Diameter)*Thickness of Plate to evaluate the Tensile Load, The Safe tensile load that plate can withstand formula is defined as maximum tensile load rivet can withstand. Tensile Load is denoted by Pload symbol.

How to evaluate Safe tensile load that plate can withstand using this online evaluator? To use this online evaluator for Safe tensile load that plate can withstand, enter Tensile Stress t), Pitch of Rivet (p), Rivet Diameter (Drivet) & Thickness of Plate (tplate) and hit the calculate button.

FAQs on Safe tensile load that plate can withstand

What is the formula to find Safe tensile load that plate can withstand?
The formula of Safe tensile load that plate can withstand is expressed as Tensile Load = Tensile Stress*(Pitch of Rivet-Rivet Diameter)*Thickness of Plate. Here is an example- 4.2E-6 = 173000*(0.02-0.018)*0.012.
How to calculate Safe tensile load that plate can withstand?
With Tensile Stress t), Pitch of Rivet (p), Rivet Diameter (Drivet) & Thickness of Plate (tplate) we can find Safe tensile load that plate can withstand using the formula - Tensile Load = Tensile Stress*(Pitch of Rivet-Rivet Diameter)*Thickness of Plate.
What are the other ways to Calculate Tensile Load?
Here are the different ways to Calculate Tensile Load-
  • Tensile Load=Tensile Stress*Area of Base PlateOpenImg
Can the Safe tensile load that plate can withstand be negative?
Yes, the Safe tensile load that plate can withstand, measured in Force can be negative.
Which unit is used to measure Safe tensile load that plate can withstand?
Safe tensile load that plate can withstand is usually measured using the Kilonewton[kN] for Force. Newton[kN], Exanewton[kN], Meganewton[kN] are the few other units in which Safe tensile load that plate can withstand can be measured.
Copied!