Fx Copy
LaTeX Copy
Safe Bearing Capacity is the maximum pressure which the soil can carry safely without risk of shear failure. Check FAQs
qsa=(qnet'FOS)+(γDfooting)
qsa - Safe Bearing Capacity?qnet' - Net Ultimate Bearing Capacity?FOS - Factor of Safety in Bearing Capacity of Soil?γ - Unit Weight of Soil?Dfooting - Depth of Footing in Soil?

Safe Bearing Capacity given Net Ultimate Bearing Capacity Example

With values
With units
Only example

Here is how the Safe Bearing Capacity given Net Ultimate Bearing Capacity equation looks like with Values.

Here is how the Safe Bearing Capacity given Net Ultimate Bearing Capacity equation looks like with Units.

Here is how the Safe Bearing Capacity given Net Ultimate Bearing Capacity equation looks like.

47.6129Edit=(5.3Edit2.8Edit)+(18Edit2.54Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Geotechnical Engineering » fx Safe Bearing Capacity given Net Ultimate Bearing Capacity

Safe Bearing Capacity given Net Ultimate Bearing Capacity Solution

Follow our step by step solution on how to calculate Safe Bearing Capacity given Net Ultimate Bearing Capacity?

FIRST Step Consider the formula
qsa=(qnet'FOS)+(γDfooting)
Next Step Substitute values of Variables
qsa=(5.3kN/m²2.8)+(18kN/m³2.54m)
Next Step Convert Units
qsa=(5300Pa2.8)+(18000N/m³2.54m)
Next Step Prepare to Evaluate
qsa=(53002.8)+(180002.54)
Next Step Evaluate
qsa=47612.8571428571Pa
Next Step Convert to Output's Unit
qsa=47.6128571428571kN/m²
LAST Step Rounding Answer
qsa=47.6129kN/m²

Safe Bearing Capacity given Net Ultimate Bearing Capacity Formula Elements

Variables
Safe Bearing Capacity
Safe Bearing Capacity is the maximum pressure which the soil can carry safely without risk of shear failure.
Symbol: qsa
Measurement: PressureUnit: kN/m²
Note: Value should be greater than 0.
Net Ultimate Bearing Capacity
Net Ultimate Bearing Capacity is the maximum load per unit area that a soil can withstand without failure under the conditions imposed by the presence of groundwater.
Symbol: qnet'
Measurement: PressureUnit: kN/m²
Note: Value should be greater than 0.
Factor of Safety in Bearing Capacity of Soil
Factor of Safety in Bearing Capacity of Soil expresses how much stronger a soil is than it needs to be for an intended load.
Symbol: FOS
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Unit Weight of Soil
Unit Weight of Soil mass is the ratio of the total weight of soil to the total volume of soil.
Symbol: γ
Measurement: Specific WeightUnit: kN/m³
Note: Value should be greater than 0.
Depth of Footing in Soil
Depth of Footing in Soil is the depth at which the foundation of a structure is placed below the ground surface. This is crucial for ensuring the stability of the structure.
Symbol: Dfooting
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Safe Bearing Capacity

​Go Safe Bearing Capacity
qsa=qnsa+(γDfooting)

Other formulas in Bearing Capacity of Soils category

​Go Ultimate Bearing Capacity of Soil under Long Footing at Surface of Soil
qf=((Ctan(Φi))+(0.5γdBKP)(KPexp(πtan(Φi))-1))
​Go Effective Surcharge given Depth of Footing
σs=γD
​Go Ultimate Bearing Capacity
qf=qnet+σs
​Go Net Ultimate Bearing Capacity given Ultimate Bearing Capacity
qnet=qf-σs

How to Evaluate Safe Bearing Capacity given Net Ultimate Bearing Capacity?

Safe Bearing Capacity given Net Ultimate Bearing Capacity evaluator uses Safe Bearing Capacity = (Net Ultimate Bearing Capacity/Factor of Safety in Bearing Capacity of Soil)+(Unit Weight of Soil*Depth of Footing in Soil) to evaluate the Safe Bearing Capacity, The Safe Bearing Capacity given Net Ultimate Bearing Capacity formula is defined as the maximum pressure that can be applied to the ground (usually soil or rock) without causing shear failure or excessive settlement. Safe Bearing Capacity is denoted by qsa symbol.

How to evaluate Safe Bearing Capacity given Net Ultimate Bearing Capacity using this online evaluator? To use this online evaluator for Safe Bearing Capacity given Net Ultimate Bearing Capacity, enter Net Ultimate Bearing Capacity (qnet'), Factor of Safety in Bearing Capacity of Soil (FOS), Unit Weight of Soil (γ) & Depth of Footing in Soil (Dfooting) and hit the calculate button.

FAQs on Safe Bearing Capacity given Net Ultimate Bearing Capacity

What is the formula to find Safe Bearing Capacity given Net Ultimate Bearing Capacity?
The formula of Safe Bearing Capacity given Net Ultimate Bearing Capacity is expressed as Safe Bearing Capacity = (Net Ultimate Bearing Capacity/Factor of Safety in Bearing Capacity of Soil)+(Unit Weight of Soil*Depth of Footing in Soil). Here is an example- 0.047613 = (5300/2.8)+(18000*2.54).
How to calculate Safe Bearing Capacity given Net Ultimate Bearing Capacity?
With Net Ultimate Bearing Capacity (qnet'), Factor of Safety in Bearing Capacity of Soil (FOS), Unit Weight of Soil (γ) & Depth of Footing in Soil (Dfooting) we can find Safe Bearing Capacity given Net Ultimate Bearing Capacity using the formula - Safe Bearing Capacity = (Net Ultimate Bearing Capacity/Factor of Safety in Bearing Capacity of Soil)+(Unit Weight of Soil*Depth of Footing in Soil).
What are the other ways to Calculate Safe Bearing Capacity?
Here are the different ways to Calculate Safe Bearing Capacity-
  • Safe Bearing Capacity=Net Safe Bearing Capacity in Soil+(Unit Weight of Soil*Depth of Footing in Soil)OpenImg
Can the Safe Bearing Capacity given Net Ultimate Bearing Capacity be negative?
No, the Safe Bearing Capacity given Net Ultimate Bearing Capacity, measured in Pressure cannot be negative.
Which unit is used to measure Safe Bearing Capacity given Net Ultimate Bearing Capacity?
Safe Bearing Capacity given Net Ultimate Bearing Capacity is usually measured using the Kilonewton per Square Meter[kN/m²] for Pressure. Pascal[kN/m²], Kilopascal[kN/m²], Bar[kN/m²] are the few other units in which Safe Bearing Capacity given Net Ultimate Bearing Capacity can be measured.
Copied!