Runoff Rate of Rainwater from Bridge during Rainstorm Formula

Fx Copy
LaTeX Copy
Peak Rate of Runoff is the maximum rate of discharge during the period of runoff caused by a storm. Check FAQs
qp=1.00083CrIAcatchment
qp - Peak Rate of Runoff?Cr - Runoff Coefficient?I - Intensity of Rainfall?Acatchment - Catchment Area for Rainstorm?

Runoff Rate of Rainwater from Bridge during Rainstorm Example

With values
With units
Only example

Here is how the Runoff Rate of Rainwater from Bridge during Rainstorm equation looks like with Values.

Here is how the Runoff Rate of Rainwater from Bridge during Rainstorm equation looks like with Units.

Here is how the Runoff Rate of Rainwater from Bridge during Rainstorm equation looks like.

1.256Edit=1.000830.5Edit16Edit9412Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Bridge and Suspension Cable » fx Runoff Rate of Rainwater from Bridge during Rainstorm

Runoff Rate of Rainwater from Bridge during Rainstorm Solution

Follow our step by step solution on how to calculate Runoff Rate of Rainwater from Bridge during Rainstorm?

FIRST Step Consider the formula
qp=1.00083CrIAcatchment
Next Step Substitute values of Variables
qp=1.000830.516mm/min9412
Next Step Convert Units
qp=1.000830.50.0003m/s9412
Next Step Prepare to Evaluate
qp=1.000830.50.00039412
Next Step Evaluate
qp=1.255974928m³/s
LAST Step Rounding Answer
qp=1.256m³/s

Runoff Rate of Rainwater from Bridge during Rainstorm Formula Elements

Variables
Peak Rate of Runoff
Peak Rate of Runoff is the maximum rate of discharge during the period of runoff caused by a storm.
Symbol: qp
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Runoff Coefficient
Runoff Coefficient is a dimensionless coefficient relating the amount of runoff to the amount of precipitation received.
Symbol: Cr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Intensity of Rainfall
Intensity of Rainfall is the ratio of the total amount of rain (rainfall depth) falling during a given period to the duration of the period.
Symbol: I
Measurement: SpeedUnit: mm/min
Note: Value can be positive or negative.
Catchment Area for Rainstorm
Catchment Area for Rainstorm is the total area of the catchment from where total runoff water is collected.
Symbol: Acatchment
Measurement: AreaUnit:
Note: Value should be greater than 0.

Other formulas in Rainwater Accumulation and Drainage on Bridges category

​Go Average Rainfall Intensity given Runoff Rate of Rainwater from Bridge during Rainstorm
I=qp1.00083CrAcatchment
​Go Drainage Area given Runoff Rate of Rainwater from Bridge during Rainstorm
Acatchment=qp1.00083CrI
​Go Runoff Coefficient given Runoff Rate of Rainwater from Bridge during Rainstorm
Cr=qp1.00083IAcatchment
​Go Deck Width for Handling Rainwater Runoff to Drain Scuppers
w=S+t3

How to Evaluate Runoff Rate of Rainwater from Bridge during Rainstorm?

Runoff Rate of Rainwater from Bridge during Rainstorm evaluator uses Peak Rate of Runoff = 1.00083*Runoff Coefficient*Intensity of Rainfall*Catchment Area for Rainstorm to evaluate the Peak Rate of Runoff, The Runoff Rate of Rainwater from Bridge during Rainstorm formula is defined as the maximum value discharge generated for a storm event. Peak Rate of Runoff is denoted by qp symbol.

How to evaluate Runoff Rate of Rainwater from Bridge during Rainstorm using this online evaluator? To use this online evaluator for Runoff Rate of Rainwater from Bridge during Rainstorm, enter Runoff Coefficient (Cr), Intensity of Rainfall (I) & Catchment Area for Rainstorm (Acatchment) and hit the calculate button.

FAQs on Runoff Rate of Rainwater from Bridge during Rainstorm

What is the formula to find Runoff Rate of Rainwater from Bridge during Rainstorm?
The formula of Runoff Rate of Rainwater from Bridge during Rainstorm is expressed as Peak Rate of Runoff = 1.00083*Runoff Coefficient*Intensity of Rainfall*Catchment Area for Rainstorm. Here is an example- 1.255975 = 1.00083*0.5*0.000266666666666667*9412.
How to calculate Runoff Rate of Rainwater from Bridge during Rainstorm?
With Runoff Coefficient (Cr), Intensity of Rainfall (I) & Catchment Area for Rainstorm (Acatchment) we can find Runoff Rate of Rainwater from Bridge during Rainstorm using the formula - Peak Rate of Runoff = 1.00083*Runoff Coefficient*Intensity of Rainfall*Catchment Area for Rainstorm.
Can the Runoff Rate of Rainwater from Bridge during Rainstorm be negative?
No, the Runoff Rate of Rainwater from Bridge during Rainstorm, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Runoff Rate of Rainwater from Bridge during Rainstorm?
Runoff Rate of Rainwater from Bridge during Rainstorm is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Runoff Rate of Rainwater from Bridge during Rainstorm can be measured.
Copied!