Runoff Quantity with Full Gutter Flow Formula

Fx Copy
LaTeX Copy
The Runoff Quantity refers to the amount of water that storms bring to the earth. Check FAQs
Qro=0.7Lo(a+y)32
Qro - Runoff Quantity?Lo - Length of Opening?a - Depression in Curb Inlet?y - Depth of Flow at Inlet?

Runoff Quantity with Full Gutter Flow Example

With values
With units
Only example

Here is how the Runoff Quantity with Full Gutter Flow equation looks like with Values.

Here is how the Runoff Quantity with Full Gutter Flow equation looks like with Units.

Here is how the Runoff Quantity with Full Gutter Flow equation looks like.

328.9804Edit=0.77Edit(4Edit+7.117Edit)32
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Runoff Quantity with Full Gutter Flow

Runoff Quantity with Full Gutter Flow Solution

Follow our step by step solution on how to calculate Runoff Quantity with Full Gutter Flow?

FIRST Step Consider the formula
Qro=0.7Lo(a+y)32
Next Step Substitute values of Variables
Qro=0.77ft(4ft+7.117ft)32
Next Step Convert Units
Qro=0.72.1336m(1.2192m+2.1693m)32
Next Step Prepare to Evaluate
Qro=0.72.1336(1.2192+2.1693)32
Next Step Evaluate
Qro=9.31568715121965m³/s
Next Step Convert to Output's Unit
Qro=328.980387023027ft³/s
LAST Step Rounding Answer
Qro=328.9804ft³/s

Runoff Quantity with Full Gutter Flow Formula Elements

Variables
Runoff Quantity
The Runoff Quantity refers to the amount of water that storms bring to the earth.
Symbol: Qro
Measurement: Volumetric Flow RateUnit: ft³/s
Note: Value should be greater than 0.
Length of Opening
The Length of Opening refers to the dimension of the structure that allows water to pass through.
Symbol: Lo
Measurement: LengthUnit: ft
Note: Value should be greater than 0.
Depression in Curb Inlet
The Depression in Curb Inlet refers to the height of depression at the curb achieved from the steeper grade of the gutter cross slope relative to the roadway cross-slope.
Symbol: a
Measurement: LengthUnit: ft
Note: Value can be positive or negative.
Depth of Flow at Inlet
The Depth of Flow at Inlet refers to the depth of water in a channel or conduit at the point where water enters a structure, such as a culvert, intake structure, or storm water inlet.
Symbol: y
Measurement: LengthUnit: ft
Note: Value can be positive or negative.

Other formulas in Disposing of Storm Water category

​Go Length of Opening given Runoff Quantity with Full Gutter Flow
Lo=Qro0.7(a+y)32
​Go Depression in Curb Inlet given Runoff Quantity with Full Gutter flow
a=((Qro0.7Lo)23)-y
​Go Depth of Flow at Inlet given Runoff Quantity with Full Gutter Flow
y=((Qro0.7Lo)23)-a
​Go Inlet Capacity for Flow Depth
Qw=3Py32

How to Evaluate Runoff Quantity with Full Gutter Flow?

Runoff Quantity with Full Gutter Flow evaluator uses Runoff Quantity = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2) to evaluate the Runoff Quantity, The Runoff quantity with full gutter flow is defined as the amount of the water flow per second when we have a prior info of opening length, depression in curb and depth of flow at the inlet. Runoff Quantity is denoted by Qro symbol.

How to evaluate Runoff Quantity with Full Gutter Flow using this online evaluator? To use this online evaluator for Runoff Quantity with Full Gutter Flow, enter Length of Opening (Lo), Depression in Curb Inlet (a) & Depth of Flow at Inlet (y) and hit the calculate button.

FAQs on Runoff Quantity with Full Gutter Flow

What is the formula to find Runoff Quantity with Full Gutter Flow?
The formula of Runoff Quantity with Full Gutter Flow is expressed as Runoff Quantity = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2). Here is an example- 11617.83 = 0.7*2.13360000000853*(1.21920000000488+2.16926160000868)^(3/2).
How to calculate Runoff Quantity with Full Gutter Flow?
With Length of Opening (Lo), Depression in Curb Inlet (a) & Depth of Flow at Inlet (y) we can find Runoff Quantity with Full Gutter Flow using the formula - Runoff Quantity = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2).
Can the Runoff Quantity with Full Gutter Flow be negative?
No, the Runoff Quantity with Full Gutter Flow, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Runoff Quantity with Full Gutter Flow?
Runoff Quantity with Full Gutter Flow is usually measured using the Cubic Foot per Second[ft³/s] for Volumetric Flow Rate. Cubic Meter per Second[ft³/s], Cubic Meter per Day[ft³/s], Cubic Meter per Hour[ft³/s] are the few other units in which Runoff Quantity with Full Gutter Flow can be measured.
Copied!