Fx Copy
LaTeX Copy
Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full. Check FAQs
np=NνsVratio(rpfRrf)23S
np - Roughness Coefficient Partially Full?N - Roughness Coefficient for Running Full?νsVratio - Velocity Ratio?rpf - Hydraulic Mean Depth for Partially Full?Rrf - Hydraulic Mean Depth while Running Full?S - Bed Slope Ratio?

Roughness Coefficient for Partial Flow given Velocity Ratio Example

With values
With units
Only example

Here is how the Roughness Coefficient for Partial Flow given Velocity Ratio equation looks like with Values.

Here is how the Roughness Coefficient for Partial Flow given Velocity Ratio equation looks like with Units.

Here is how the Roughness Coefficient for Partial Flow given Velocity Ratio equation looks like.

0.9451Edit=0.74Edit0.76Edit(3.2Edit5.2Edit)231.8Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Roughness Coefficient for Partial Flow given Velocity Ratio

Roughness Coefficient for Partial Flow given Velocity Ratio Solution

Follow our step by step solution on how to calculate Roughness Coefficient for Partial Flow given Velocity Ratio?

FIRST Step Consider the formula
np=NνsVratio(rpfRrf)23S
Next Step Substitute values of Variables
np=0.740.76(3.2m5.2m)231.8
Next Step Prepare to Evaluate
np=0.740.76(3.25.2)231.8
Next Step Evaluate
np=0.945116771101621
LAST Step Rounding Answer
np=0.9451

Roughness Coefficient for Partial Flow given Velocity Ratio Formula Elements

Variables
Functions
Roughness Coefficient Partially Full
Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full.
Symbol: np
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Roughness Coefficient for Running Full
The Roughness Coefficient for Running Full accounts for uniform surface resistance affecting flow velocity and friction loss.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Velocity Ratio
The Velocity Ratio compares the flow velocity in a partially full pipe to that in a fully running pipe.
Symbol: νsVratio
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Hydraulic Mean Depth for Partially Full
Hydraulic Mean Depth for Partially Full refers to the cross-sectional area of flow divided by the wetted perimeter, adapting to varying water levels.
Symbol: rpf
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Hydraulic Mean Depth while Running Full
Hydraulic Mean Depth while Running Full refers to the ratio of the pipe's full cross-sectional area to its full wetted perimeter.
Symbol: Rrf
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Bed Slope Ratio
The Bed Slope Ratio refers to the slope of a partially full pipe to the slope when it is completely full.
Symbol: S
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Roughness Coefficient Partially Full

​Go Roughness Coefficient for Partial Flow given Self Cleansing Velocity
np=NVsV(rpfRrf)23S
​Go Roughness Coefficient for Partial Flow given Hydraulic Mean Depth Ratio
np=NVsV(R)16
​Go Roughness Coefficient for Partial Flow given Hydraulic Mean Depth and Velocity Ratio
np=NνsVratio(R)16
​Go Roughness Coefficient for Partial Flow given Discharge Ratio
np=NqsQratio(aA)(rpfRrf)16

How to Evaluate Roughness Coefficient for Partial Flow given Velocity Ratio?

Roughness Coefficient for Partial Flow given Velocity Ratio evaluator uses Roughness Coefficient Partially Full = Roughness Coefficient for Running Full/(Velocity Ratio/((Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio))) to evaluate the Roughness Coefficient Partially Full, Roughness Coefficient for Partial Flow given Velocity Ratio is defined for flow calculations, accounting for varied wetting of pipe surfaces. Roughness Coefficient Partially Full is denoted by np symbol.

How to evaluate Roughness Coefficient for Partial Flow given Velocity Ratio using this online evaluator? To use this online evaluator for Roughness Coefficient for Partial Flow given Velocity Ratio, enter Roughness Coefficient for Running Full (N), Velocity Ratio (νsVratio), Hydraulic Mean Depth for Partially Full (rpf), Hydraulic Mean Depth while Running Full (Rrf) & Bed Slope Ratio (S) and hit the calculate button.

FAQs on Roughness Coefficient for Partial Flow given Velocity Ratio

What is the formula to find Roughness Coefficient for Partial Flow given Velocity Ratio?
The formula of Roughness Coefficient for Partial Flow given Velocity Ratio is expressed as Roughness Coefficient Partially Full = Roughness Coefficient for Running Full/(Velocity Ratio/((Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio))). Here is an example- 0.359144 = 0.74/(velocity_ratio_/((3.2/5.2)^(2/3)*sqrt(1.8))).
How to calculate Roughness Coefficient for Partial Flow given Velocity Ratio?
With Roughness Coefficient for Running Full (N), Velocity Ratio (νsVratio), Hydraulic Mean Depth for Partially Full (rpf), Hydraulic Mean Depth while Running Full (Rrf) & Bed Slope Ratio (S) we can find Roughness Coefficient for Partial Flow given Velocity Ratio using the formula - Roughness Coefficient Partially Full = Roughness Coefficient for Running Full/(Velocity Ratio/((Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio))). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Roughness Coefficient Partially Full?
Here are the different ways to Calculate Roughness Coefficient Partially Full-
  • Roughness Coefficient Partially Full=Roughness Coefficient for Running Full/((Velocity in a Partially Running Sewer/Velocity While Running Full)/((Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio)))OpenImg
  • Roughness Coefficient Partially Full=Roughness Coefficient for Running Full/((Velocity in a Partially Running Sewer/Velocity While Running Full)/(Hydraulic Mean Depth Ratio)^(1/6))OpenImg
  • Roughness Coefficient Partially Full=Roughness Coefficient for Running Full/((Velocity Ratio)/(Hydraulic Mean Depth Ratio)^(1/6))OpenImg
Copied!