Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full. Check FAQs
np=NqsQratio(aA)(rpfRrf)16
np - Roughness Coefficient Partially Full?N - Roughness Coefficient for Running Full?qsQratio - Discharge Ratio?a - Area of Partially Full Sewers?A - Area of Running Full Sewers?rpf - Hydraulic Mean Depth for Partially Full?Rrf - Hydraulic Mean Depth while Running Full?

Roughness Coefficient for Partial Flow given Discharge Ratio Example

With values
With units
Only example

Here is how the Roughness Coefficient for Partial Flow given Discharge Ratio equation looks like with Values.

Here is how the Roughness Coefficient for Partial Flow given Discharge Ratio equation looks like with Units.

Here is how the Roughness Coefficient for Partial Flow given Discharge Ratio equation looks like.

0.9028Edit=0.74Edit0.532Edit(3.8Edit5.4Edit)(3.2Edit5.2Edit)16
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Roughness Coefficient for Partial Flow given Discharge Ratio

Roughness Coefficient for Partial Flow given Discharge Ratio Solution

Follow our step by step solution on how to calculate Roughness Coefficient for Partial Flow given Discharge Ratio?

FIRST Step Consider the formula
np=NqsQratio(aA)(rpfRrf)16
Next Step Substitute values of Variables
np=0.740.532(3.85.4)(3.2m5.2m)16
Next Step Prepare to Evaluate
np=0.740.532(3.85.4)(3.25.2)16
Next Step Evaluate
np=0.902750414855519
LAST Step Rounding Answer
np=0.9028

Roughness Coefficient for Partial Flow given Discharge Ratio Formula Elements

Variables
Roughness Coefficient Partially Full
Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full.
Symbol: np
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Roughness Coefficient for Running Full
The Roughness Coefficient for Running Full accounts for uniform surface resistance affecting flow velocity and friction loss.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Discharge Ratio
Discharge Ratio is the ratio of discharge at partial flow to discharge at full flow.
Symbol: qsQratio
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Area of Partially Full Sewers
The Area of Partially Full Sewers refers to the cross-sectional flow area at a given water depth, crucial for hydraulic and flow rate calculations.
Symbol: a
Measurement: AreaUnit:
Note: Value should be greater than 0.
Area of Running Full Sewers
The Area of Running Full Sewers refers to the total cross-sectional area of the pipe when it is completely filled with fluid.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Hydraulic Mean Depth for Partially Full
Hydraulic Mean Depth for Partially Full refers to the cross-sectional area of flow divided by the wetted perimeter, adapting to varying water levels.
Symbol: rpf
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Hydraulic Mean Depth while Running Full
Hydraulic Mean Depth while Running Full refers to the ratio of the pipe's full cross-sectional area to its full wetted perimeter.
Symbol: Rrf
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Roughness Coefficient Partially Full

​Go Roughness Coefficient for Partial Flow given Velocity Ratio
np=NνsVratio(rpfRrf)23S
​Go Roughness Coefficient for Partial Flow given Self Cleansing Velocity
np=NVsV(rpfRrf)23S

How to Evaluate Roughness Coefficient for Partial Flow given Discharge Ratio?

Roughness Coefficient for Partial Flow given Discharge Ratio evaluator uses Roughness Coefficient Partially Full = Roughness Coefficient for Running Full/((Discharge Ratio)/((Area of Partially Full Sewers/Area of Running Full Sewers)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6))) to evaluate the Roughness Coefficient Partially Full, The Roughness Coefficient for Partial Flow given Discharge Ratio is defined for flow calculations, accounting for varied wetting of pipe surfaces. Roughness Coefficient Partially Full is denoted by np symbol.

How to evaluate Roughness Coefficient for Partial Flow given Discharge Ratio using this online evaluator? To use this online evaluator for Roughness Coefficient for Partial Flow given Discharge Ratio, enter Roughness Coefficient for Running Full (N), Discharge Ratio (qsQratio), Area of Partially Full Sewers (a), Area of Running Full Sewers (A), Hydraulic Mean Depth for Partially Full (rpf) & Hydraulic Mean Depth while Running Full (Rrf) and hit the calculate button.

FAQs on Roughness Coefficient for Partial Flow given Discharge Ratio

What is the formula to find Roughness Coefficient for Partial Flow given Discharge Ratio?
The formula of Roughness Coefficient for Partial Flow given Discharge Ratio is expressed as Roughness Coefficient Partially Full = Roughness Coefficient for Running Full/((Discharge Ratio)/((Area of Partially Full Sewers/Area of Running Full Sewers)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6))). Here is an example- 1.624951 = 0.74/((0.532)/((3.8/area_while_running_full)*(3.2/5.2)^(1/6))).
How to calculate Roughness Coefficient for Partial Flow given Discharge Ratio?
With Roughness Coefficient for Running Full (N), Discharge Ratio (qsQratio), Area of Partially Full Sewers (a), Area of Running Full Sewers (A), Hydraulic Mean Depth for Partially Full (rpf) & Hydraulic Mean Depth while Running Full (Rrf) we can find Roughness Coefficient for Partial Flow given Discharge Ratio using the formula - Roughness Coefficient Partially Full = Roughness Coefficient for Running Full/((Discharge Ratio)/((Area of Partially Full Sewers/Area of Running Full Sewers)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6))).
What are the other ways to Calculate Roughness Coefficient Partially Full?
Here are the different ways to Calculate Roughness Coefficient Partially Full-
  • Roughness Coefficient Partially Full=Roughness Coefficient for Running Full/(Velocity Ratio/((Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio)))OpenImg
  • Roughness Coefficient Partially Full=Roughness Coefficient for Running Full/((Velocity in a Partially Running Sewer/Velocity While Running Full)/((Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio)))OpenImg
  • Roughness Coefficient Partially Full=Roughness Coefficient for Running Full/((Velocity in a Partially Running Sewer/Velocity While Running Full)/(Hydraulic Mean Depth Ratio)^(1/6))OpenImg
Copied!