Fx Copy
LaTeX Copy
The Roughness Coefficient for Running Full accounts for uniform surface resistance affecting flow velocity and friction loss. Check FAQs
N=np(qsQratio(aA)(R)16)
N - Roughness Coefficient for Running Full?np - Roughness Coefficient Partially Full?qsQratio - Discharge Ratio?a - Area of Partially Full Sewers?A - Area of Running Full Sewers?R - Hydraulic Mean Depth Ratio?

Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio Example

With values
With units
Only example

Here is how the Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio equation looks like with Values.

Here is how the Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio equation looks like with Units.

Here is how the Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio equation looks like.

0.7388Edit=0.9Edit(0.532Edit(3.8Edit5.4Edit)(0.61Edit)16)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio

Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio Solution

Follow our step by step solution on how to calculate Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio?

FIRST Step Consider the formula
N=np(qsQratio(aA)(R)16)
Next Step Substitute values of Variables
N=0.9(0.532(3.85.4)(0.61)16)
Next Step Prepare to Evaluate
N=0.9(0.532(3.85.4)(0.61)16)
Next Step Evaluate
N=0.738826842937957
LAST Step Rounding Answer
N=0.7388

Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio Formula Elements

Variables
Roughness Coefficient for Running Full
The Roughness Coefficient for Running Full accounts for uniform surface resistance affecting flow velocity and friction loss.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Roughness Coefficient Partially Full
Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full.
Symbol: np
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Discharge Ratio
Discharge Ratio is the ratio of discharge at partial flow to discharge at full flow.
Symbol: qsQratio
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Area of Partially Full Sewers
The Area of Partially Full Sewers refers to the cross-sectional flow area at a given water depth, crucial for hydraulic and flow rate calculations.
Symbol: a
Measurement: AreaUnit:
Note: Value should be greater than 0.
Area of Running Full Sewers
The Area of Running Full Sewers refers to the total cross-sectional area of the pipe when it is completely filled with fluid.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Hydraulic Mean Depth Ratio
The Hydraulic Mean Depth Ratio refers to the ratio of the hydraulic mean depth for a partially full pipe to that when it's running full.
Symbol: R
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Roughness Coefficient for Running Full

​Go Roughness Coefficient for Full Flow given Velocity Ratio
N=np(νsVratio(rpfRrf)23S)
​Go Roughness Coefficient for Full Flow given Self Cleansing Velocity
N=np(VsV(rpfRrf)23S)
​Go Roughness Coefficient for Full Flow given Hydraulic Mean Depth Ratio
N=((VsV)(R)16)np
​Go Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Velocity Ratio
N=(νsVratio(R)16)np

How to Evaluate Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio?

Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio evaluator uses Roughness Coefficient for Running Full = Roughness Coefficient Partially Full*((Discharge Ratio)/((Area of Partially Full Sewers/Area of Running Full Sewers)*(Hydraulic Mean Depth Ratio)^(1/6))) to evaluate the Roughness Coefficient for Running Full, Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio is defined for uniform surface resistance affecting flow velocity and friction loss. Roughness Coefficient for Running Full is denoted by N symbol.

How to evaluate Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio using this online evaluator? To use this online evaluator for Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio, enter Roughness Coefficient Partially Full (np), Discharge Ratio (qsQratio), Area of Partially Full Sewers (a), Area of Running Full Sewers (A) & Hydraulic Mean Depth Ratio (R) and hit the calculate button.

FAQs on Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio

What is the formula to find Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio?
The formula of Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio is expressed as Roughness Coefficient for Running Full = Roughness Coefficient Partially Full*((Discharge Ratio)/((Area of Partially Full Sewers/Area of Running Full Sewers)*(Hydraulic Mean Depth Ratio)^(1/6))). Here is an example- 0.410459 = 0.9*((0.532)/((3.8/area_while_running_full)*(0.61)^(1/6))).
How to calculate Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio?
With Roughness Coefficient Partially Full (np), Discharge Ratio (qsQratio), Area of Partially Full Sewers (a), Area of Running Full Sewers (A) & Hydraulic Mean Depth Ratio (R) we can find Roughness Coefficient for Full Flow given Hydraulic Mean Depth and Discharge Ratio using the formula - Roughness Coefficient for Running Full = Roughness Coefficient Partially Full*((Discharge Ratio)/((Area of Partially Full Sewers/Area of Running Full Sewers)*(Hydraulic Mean Depth Ratio)^(1/6))).
What are the other ways to Calculate Roughness Coefficient for Running Full?
Here are the different ways to Calculate Roughness Coefficient for Running Full-
  • Roughness Coefficient for Running Full=Roughness Coefficient Partially Full*(Velocity Ratio/((Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio)))OpenImg
  • Roughness Coefficient for Running Full=Roughness Coefficient Partially Full*((Velocity in a Partially Running Sewer/Velocity While Running Full)/((Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio)))OpenImg
  • Roughness Coefficient for Running Full=(((Velocity in a Partially Running Sewer/Velocity While Running Full))/(Hydraulic Mean Depth Ratio)^(1/6))*Roughness Coefficient Partially FullOpenImg
Copied!