Roof Live Load is the load to which roof is subjected in addition to its own weight. Check FAQs
Lf=20(1.2-0.001At)R2
Lf - Roof Live Load?At - Tributary Area?R2 - Reduction Factor for Slope of Roof?

Roof Live Load when Tributary Area Les in Range 200 to 600 square feet Example

With values
With units
Only example

Here is how the Roof Live Load when Tributary Area Les in Range 200 to 600 square feet equation looks like with Values.

Here is how the Roof Live Load when Tributary Area Les in Range 200 to 600 square feet equation looks like with Units.

Here is how the Roof Live Load when Tributary Area Les in Range 200 to 600 square feet equation looks like.

17.9498Edit=20(1.2-0.0012182.782Edit)0.9Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Structural Engineering » fx Roof Live Load when Tributary Area Les in Range 200 to 600 square feet

Roof Live Load when Tributary Area Les in Range 200 to 600 square feet Solution

Follow our step by step solution on how to calculate Roof Live Load when Tributary Area Les in Range 200 to 600 square feet?

FIRST Step Consider the formula
Lf=20(1.2-0.001At)R2
Next Step Substitute values of Variables
Lf=20(1.2-0.0012182.782ft²)0.9
Next Step Convert Units
Lf=20(1.2-0.001202.7871)0.9
Next Step Prepare to Evaluate
Lf=20(1.2-0.001202.7871)0.9
Next Step Evaluate
Lf=17.9498324977397N
LAST Step Rounding Answer
Lf=17.9498N

Roof Live Load when Tributary Area Les in Range 200 to 600 square feet Formula Elements

Variables
Roof Live Load
Roof Live Load is the load to which roof is subjected in addition to its own weight.
Symbol: Lf
Measurement: ForceUnit: N
Note: Value should be greater than 0.
Tributary Area
Tributary Area is the area contributing load to the structural member.
Symbol: At
Measurement: AreaUnit: ft²
Note: Value should be greater than 0.
Reduction Factor for Slope of Roof
The Reduction Factor for Slope of Roof is the factor by which the slope of the roof reduces.
Symbol: R2
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Roof Live Load

​Go Roof Live Load
Lf=20R1R2

Other formulas in Roof Live Loads category

​Go Tributary Area given Roof Live Load
At=1000(1.2-(Lf20R2))

How to Evaluate Roof Live Load when Tributary Area Les in Range 200 to 600 square feet?

Roof Live Load when Tributary Area Les in Range 200 to 600 square feet evaluator uses Roof Live Load = 20*(1.2-0.001*Tributary Area)*Reduction Factor for Slope of Roof to evaluate the Roof Live Load, The Roof Live Load when Tributary Area Les in Range 200 to 600 square feet is defined as the live load on roof when the tributary area is more than 200 square feet but less than 600 square feet. Roof Live Load is denoted by Lf symbol.

How to evaluate Roof Live Load when Tributary Area Les in Range 200 to 600 square feet using this online evaluator? To use this online evaluator for Roof Live Load when Tributary Area Les in Range 200 to 600 square feet, enter Tributary Area (At) & Reduction Factor for Slope of Roof (R2) and hit the calculate button.

FAQs on Roof Live Load when Tributary Area Les in Range 200 to 600 square feet

What is the formula to find Roof Live Load when Tributary Area Les in Range 200 to 600 square feet?
The formula of Roof Live Load when Tributary Area Les in Range 200 to 600 square feet is expressed as Roof Live Load = 20*(1.2-0.001*Tributary Area)*Reduction Factor for Slope of Roof. Here is an example- 17.94983 = 20*(1.2-0.001*202.787083458903)*0.9.
How to calculate Roof Live Load when Tributary Area Les in Range 200 to 600 square feet?
With Tributary Area (At) & Reduction Factor for Slope of Roof (R2) we can find Roof Live Load when Tributary Area Les in Range 200 to 600 square feet using the formula - Roof Live Load = 20*(1.2-0.001*Tributary Area)*Reduction Factor for Slope of Roof.
What are the other ways to Calculate Roof Live Load?
Here are the different ways to Calculate Roof Live Load-
  • Roof Live Load=20*Reduction Factor for Size of Tributary Area*Reduction Factor for Slope of RoofOpenImg
Can the Roof Live Load when Tributary Area Les in Range 200 to 600 square feet be negative?
No, the Roof Live Load when Tributary Area Les in Range 200 to 600 square feet, measured in Force cannot be negative.
Which unit is used to measure Roof Live Load when Tributary Area Les in Range 200 to 600 square feet?
Roof Live Load when Tributary Area Les in Range 200 to 600 square feet is usually measured using the Newton[N] for Force. Exanewton[N], Meganewton[N], Kilonewton[N] are the few other units in which Roof Live Load when Tributary Area Les in Range 200 to 600 square feet can be measured.