Root Mean Square Voltage is the square root of the time average of the voltage squared. Check FAQs
Vrms=(Pcos(Φ))RPloss
Vrms - Root Mean Square Voltage?P - Power Transmitted?Φ - Phase Difference?R - Resistance Underground AC?Ploss - Line Losses?

RMS Voltage using Line Losses (2 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the RMS Voltage using Line Losses (2 Phase 4 Wire US) equation looks like with Values.

Here is how the RMS Voltage using Line Losses (2 Phase 4 Wire US) equation looks like with Units.

Here is how the RMS Voltage using Line Losses (2 Phase 4 Wire US) equation looks like.

474.0455Edit=(300Editcos(30Edit))5Edit2.67Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx RMS Voltage using Line Losses (2 Phase 4 Wire US)

RMS Voltage using Line Losses (2 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate RMS Voltage using Line Losses (2 Phase 4 Wire US)?

FIRST Step Consider the formula
Vrms=(Pcos(Φ))RPloss
Next Step Substitute values of Variables
Vrms=(300Wcos(30°))5Ω2.67W
Next Step Convert Units
Vrms=(300Wcos(0.5236rad))5Ω2.67W
Next Step Prepare to Evaluate
Vrms=(300cos(0.5236))52.67
Next Step Evaluate
Vrms=474.045463139977V
LAST Step Rounding Answer
Vrms=474.0455V

RMS Voltage using Line Losses (2 Phase 4 Wire US) Formula Elements

Variables
Functions
Root Mean Square Voltage
Root Mean Square Voltage is the square root of the time average of the voltage squared.
Symbol: Vrms
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Root Mean Square Voltage

​Go RMS Voltage using Area of X-Section (2 Phase 4 Wire US)
Vrms=(Pcos(Φ))ρLPlossA
​Go RMS Voltage using Load Current (2 Phase 4 Wire US)
Vrms=PIcos(Φ)

Other formulas in Current and Voltage category

​Go Load Current using Line Losses (2 Phase 4 Wire US)
I=Ploss2R
​Go Maximum Voltage using Area of X-Section (2 Phase 4 Wire US)
Vm=(2Pcos(Φ))ρLPlossA
​Go Load Current using Area of X-Section (2 Phase 4 Wire US)
I=PlossA2ρL
​Go Maximum Voltage using Line Losses (2 Phase 4 Wire US)
Vm=(2Pcos(Φ))RPloss

How to Evaluate RMS Voltage using Line Losses (2 Phase 4 Wire US)?

RMS Voltage using Line Losses (2 Phase 4 Wire US) evaluator uses Root Mean Square Voltage = (Power Transmitted/cos(Phase Difference))*sqrt(Resistance Underground AC/(Line Losses)) to evaluate the Root Mean Square Voltage, The RMS Voltage using Line Losses (2 phase 4 wire US) formula is defined as the square root of the time average of the voltage squared. Root Mean Square Voltage is denoted by Vrms symbol.

How to evaluate RMS Voltage using Line Losses (2 Phase 4 Wire US) using this online evaluator? To use this online evaluator for RMS Voltage using Line Losses (2 Phase 4 Wire US), enter Power Transmitted (P), Phase Difference (Φ), Resistance Underground AC (R) & Line Losses (Ploss) and hit the calculate button.

FAQs on RMS Voltage using Line Losses (2 Phase 4 Wire US)

What is the formula to find RMS Voltage using Line Losses (2 Phase 4 Wire US)?
The formula of RMS Voltage using Line Losses (2 Phase 4 Wire US) is expressed as Root Mean Square Voltage = (Power Transmitted/cos(Phase Difference))*sqrt(Resistance Underground AC/(Line Losses)). Here is an example- 474.0455 = (300/cos(0.5235987755982))*sqrt(5/(2.67)).
How to calculate RMS Voltage using Line Losses (2 Phase 4 Wire US)?
With Power Transmitted (P), Phase Difference (Φ), Resistance Underground AC (R) & Line Losses (Ploss) we can find RMS Voltage using Line Losses (2 Phase 4 Wire US) using the formula - Root Mean Square Voltage = (Power Transmitted/cos(Phase Difference))*sqrt(Resistance Underground AC/(Line Losses)). This formula also uses Cosine (cos), Square Root (sqrt) function(s).
What are the other ways to Calculate Root Mean Square Voltage?
Here are the different ways to Calculate Root Mean Square Voltage-
  • Root Mean Square Voltage=(Power Transmitted/cos(Phase Difference))*sqrt(Resistivity*Length of Underground AC Wire/(Line Losses*Area of Underground AC Wire))OpenImg
  • Root Mean Square Voltage=Power Transmitted/(Current Underground AC*cos(Phase Difference))OpenImg
Can the RMS Voltage using Line Losses (2 Phase 4 Wire US) be negative?
No, the RMS Voltage using Line Losses (2 Phase 4 Wire US), measured in Electric Potential cannot be negative.
Which unit is used to measure RMS Voltage using Line Losses (2 Phase 4 Wire US)?
RMS Voltage using Line Losses (2 Phase 4 Wire US) is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which RMS Voltage using Line Losses (2 Phase 4 Wire US) can be measured.
Copied!