Fx Copy
LaTeX Copy
Root Mean Square Voltage is the square root of the time average of the voltage squared. Check FAQs
Vrms=2LρP2APlosscos(Φ)2
Vrms - Root Mean Square Voltage?L - Length of Overhead AC Wire?ρ - Resistivity?P - Power Transmitted?A - Area of Overhead AC Wire?Ploss - Line Losses?Φ - Phase Difference?

RMS Voltage using Area of X-Section(Single Phase Two Wire OS) Example

With values
With units
Only example

Here is how the RMS Voltage using Area of X-Section(Single Phase Two Wire OS) equation looks like with Values.

Here is how the RMS Voltage using Area of X-Section(Single Phase Two Wire OS) equation looks like with Units.

Here is how the RMS Voltage using Area of X-Section(Single Phase Two Wire OS) equation looks like.

7.6622Edit=210.63Edit1.7E-5Edit890Edit20.79Edit8.23Editcos(30Edit)2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx RMS Voltage using Area of X-Section(Single Phase Two Wire OS)

RMS Voltage using Area of X-Section(Single Phase Two Wire OS) Solution

Follow our step by step solution on how to calculate RMS Voltage using Area of X-Section(Single Phase Two Wire OS)?

FIRST Step Consider the formula
Vrms=2LρP2APlosscos(Φ)2
Next Step Substitute values of Variables
Vrms=210.63m1.7E-5Ω*m890W20.798.23Wcos(30°)2
Next Step Convert Units
Vrms=210.63m1.7E-5Ω*m890W20.798.23Wcos(0.5236rad)2
Next Step Prepare to Evaluate
Vrms=210.631.7E-589020.798.23cos(0.5236)2
Next Step Evaluate
Vrms=7.66217386495464V
LAST Step Rounding Answer
Vrms=7.6622V

RMS Voltage using Area of X-Section(Single Phase Two Wire OS) Formula Elements

Variables
Functions
Root Mean Square Voltage
Root Mean Square Voltage is the square root of the time average of the voltage squared.
Symbol: Vrms
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Area of Overhead AC Wire
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Root Mean Square Voltage

​Go RMS Voltage using Load Current (Single Phase Two Wire OS)
Vrms=PIcos(Φ)

Other formulas in Current and Voltage category

​Go Load Current(Single Phase Two Wire OS)
I=2PVaccos(Φ)
​Go Maximum Voltage using Area of X-Section(Single Phase Two Wire OS)
Vm=4LρP2APlosscos(Φ)2

How to Evaluate RMS Voltage using Area of X-Section(Single Phase Two Wire OS)?

RMS Voltage using Area of X-Section(Single Phase Two Wire OS) evaluator uses Root Mean Square Voltage = sqrt((2*Length of Overhead AC Wire*Resistivity*Power Transmitted^2)/(Area of Overhead AC Wire*Line Losses*cos(Phase Difference)^2)) to evaluate the Root Mean Square Voltage, The RMS Voltage using Area of X-section(single Phase two Wire OS) formula is defined as the square root of the time average of the voltage squared. Root Mean Square Voltage is denoted by Vrms symbol.

How to evaluate RMS Voltage using Area of X-Section(Single Phase Two Wire OS) using this online evaluator? To use this online evaluator for RMS Voltage using Area of X-Section(Single Phase Two Wire OS), enter Length of Overhead AC Wire (L), Resistivity (ρ), Power Transmitted (P), Area of Overhead AC Wire (A), Line Losses (Ploss) & Phase Difference (Φ) and hit the calculate button.

FAQs on RMS Voltage using Area of X-Section(Single Phase Two Wire OS)

What is the formula to find RMS Voltage using Area of X-Section(Single Phase Two Wire OS)?
The formula of RMS Voltage using Area of X-Section(Single Phase Two Wire OS) is expressed as Root Mean Square Voltage = sqrt((2*Length of Overhead AC Wire*Resistivity*Power Transmitted^2)/(Area of Overhead AC Wire*Line Losses*cos(Phase Difference)^2)). Here is an example- 7.662174 = sqrt((2*10.63*1.7E-05*890^2)/(0.79*8.23*cos(0.5235987755982)^2)).
How to calculate RMS Voltage using Area of X-Section(Single Phase Two Wire OS)?
With Length of Overhead AC Wire (L), Resistivity (ρ), Power Transmitted (P), Area of Overhead AC Wire (A), Line Losses (Ploss) & Phase Difference (Φ) we can find RMS Voltage using Area of X-Section(Single Phase Two Wire OS) using the formula - Root Mean Square Voltage = sqrt((2*Length of Overhead AC Wire*Resistivity*Power Transmitted^2)/(Area of Overhead AC Wire*Line Losses*cos(Phase Difference)^2)). This formula also uses Cosine (cos), Square Root (sqrt) function(s).
What are the other ways to Calculate Root Mean Square Voltage?
Here are the different ways to Calculate Root Mean Square Voltage-
  • Root Mean Square Voltage=Power Transmitted/(Current Overhead AC*cos(Phase Difference))OpenImg
Can the RMS Voltage using Area of X-Section(Single Phase Two Wire OS) be negative?
No, the RMS Voltage using Area of X-Section(Single Phase Two Wire OS), measured in Electric Potential cannot be negative.
Which unit is used to measure RMS Voltage using Area of X-Section(Single Phase Two Wire OS)?
RMS Voltage using Area of X-Section(Single Phase Two Wire OS) is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which RMS Voltage using Area of X-Section(Single Phase Two Wire OS) can be measured.
Copied!