RMS Load Voltage of Three Phase Uncontrolled Rectifier Formula

Fx Copy
LaTeX Copy
RMS Load Voltage is typically higher than the average load voltage, because the load voltage is a pulsating DC voltage with a ripple voltage superimposed on it. Check FAQs
VL(rms)=nVmax21+332π
VL(rms) - RMS Load Voltage?n - Winding Ratio?Vmax - Peak Input Voltage?π - Archimedes' constant?

RMS Load Voltage of Three Phase Uncontrolled Rectifier Example

With values
With units
Only example

Here is how the RMS Load Voltage of Three Phase Uncontrolled Rectifier equation looks like with Values.

Here is how the RMS Load Voltage of Three Phase Uncontrolled Rectifier equation looks like with Units.

Here is how the RMS Load Voltage of Three Phase Uncontrolled Rectifier equation looks like.

3154.0417Edit=15Edit220Edit21+3323.1416
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx RMS Load Voltage of Three Phase Uncontrolled Rectifier

RMS Load Voltage of Three Phase Uncontrolled Rectifier Solution

Follow our step by step solution on how to calculate RMS Load Voltage of Three Phase Uncontrolled Rectifier?

FIRST Step Consider the formula
VL(rms)=nVmax21+332π
Next Step Substitute values of Variables
VL(rms)=15220V21+332π
Next Step Substitute values of Constants
VL(rms)=15220V21+3323.1416
Next Step Prepare to Evaluate
VL(rms)=1522021+3323.1416
Next Step Evaluate
VL(rms)=3154.04165371313V
LAST Step Rounding Answer
VL(rms)=3154.0417V

RMS Load Voltage of Three Phase Uncontrolled Rectifier Formula Elements

Variables
Constants
Functions
RMS Load Voltage
RMS Load Voltage is typically higher than the average load voltage, because the load voltage is a pulsating DC voltage with a ripple voltage superimposed on it.
Symbol: VL(rms)
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Winding Ratio
Winding Ratio of an uncontrolled rectifier is the ratio of the number of turns on the primary winding to the number of turns on the secondary winding of the transformer.
Symbol: n
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Peak Input Voltage
Peak Input Voltage is the peak of the alternating voltage provided at the input of any electrical circuit.
Symbol: Vmax
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Full Wave category

​Go Load Voltage of Full Wave Three Phase Uncontrolled Rectifier
Vac=2nVmaxπ
​Go Average Load Current of Three Phase Uncontrolled Rectifier
IL(avg)=33nVmax2πRL
​Go Power Delivered to Load in Three Phase Uncontrolled Rectifier
Pout=VacVdc
​Go RMS Load Current of Three Phase Uncontrolled Rectifier
IL(rms)=nVmaxRL21+332π

How to Evaluate RMS Load Voltage of Three Phase Uncontrolled Rectifier?

RMS Load Voltage of Three Phase Uncontrolled Rectifier evaluator uses RMS Load Voltage = (Winding Ratio*Peak Input Voltage)/sqrt(2)*sqrt(1+(3*sqrt(3))/(2*pi)) to evaluate the RMS Load Voltage, RMS load Voltage of Three Phase Uncontrolled Rectifier is important because it is the voltage that is seen by the load circuit. It is also the voltage that is used to calculate the power delivered to the load. The RMS value of the load voltage of an uncontrolled rectifier is always higher than the average load voltage. This is because the load voltage of an uncontrolled rectifier is a pulsating DC voltage with a ripple voltage superimposed on it. The ripple voltage is the AC component of the load voltage, and it is caused by the fact that the rectified sinusoidal waveform is not a pure DC waveform. RMS Load Voltage is denoted by VL(rms) symbol.

How to evaluate RMS Load Voltage of Three Phase Uncontrolled Rectifier using this online evaluator? To use this online evaluator for RMS Load Voltage of Three Phase Uncontrolled Rectifier, enter Winding Ratio (n) & Peak Input Voltage (Vmax) and hit the calculate button.

FAQs on RMS Load Voltage of Three Phase Uncontrolled Rectifier

What is the formula to find RMS Load Voltage of Three Phase Uncontrolled Rectifier?
The formula of RMS Load Voltage of Three Phase Uncontrolled Rectifier is expressed as RMS Load Voltage = (Winding Ratio*Peak Input Voltage)/sqrt(2)*sqrt(1+(3*sqrt(3))/(2*pi)). Here is an example- 3154.042 = (15*220)/sqrt(2)*sqrt(1+(3*sqrt(3))/(2*pi)).
How to calculate RMS Load Voltage of Three Phase Uncontrolled Rectifier?
With Winding Ratio (n) & Peak Input Voltage (Vmax) we can find RMS Load Voltage of Three Phase Uncontrolled Rectifier using the formula - RMS Load Voltage = (Winding Ratio*Peak Input Voltage)/sqrt(2)*sqrt(1+(3*sqrt(3))/(2*pi)). This formula also uses Archimedes' constant and Square Root (sqrt) function(s).
Can the RMS Load Voltage of Three Phase Uncontrolled Rectifier be negative?
No, the RMS Load Voltage of Three Phase Uncontrolled Rectifier, measured in Electric Potential cannot be negative.
Which unit is used to measure RMS Load Voltage of Three Phase Uncontrolled Rectifier?
RMS Load Voltage of Three Phase Uncontrolled Rectifier is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which RMS Load Voltage of Three Phase Uncontrolled Rectifier can be measured.
Copied!