RMS Load Current of Three Phase Uncontrolled Rectifier Formula

Fx Copy
LaTeX Copy
RMS load current is a measure of the effective or equivalent current flowing through a load in an alternating current (AC) circuit. Check FAQs
IL(rms)=nVmaxRL21+332π
IL(rms) - RMS Load Current?n - Winding Ratio?Vmax - Peak Input Voltage?RL - Load Resistance?π - Archimedes' constant?

RMS Load Current of Three Phase Uncontrolled Rectifier Example

With values
With units
Only example

Here is how the RMS Load Current of Three Phase Uncontrolled Rectifier equation looks like with Values.

Here is how the RMS Load Current of Three Phase Uncontrolled Rectifier equation looks like with Units.

Here is how the RMS Load Current of Three Phase Uncontrolled Rectifier equation looks like.

451.222Edit=15Edit220Edit6.99Edit21+3323.1416
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx RMS Load Current of Three Phase Uncontrolled Rectifier

RMS Load Current of Three Phase Uncontrolled Rectifier Solution

Follow our step by step solution on how to calculate RMS Load Current of Three Phase Uncontrolled Rectifier?

FIRST Step Consider the formula
IL(rms)=nVmaxRL21+332π
Next Step Substitute values of Variables
IL(rms)=15220V6.99Ω21+332π
Next Step Substitute values of Constants
IL(rms)=15220V6.99Ω21+3323.1416
Next Step Prepare to Evaluate
IL(rms)=152206.9921+3323.1416
Next Step Evaluate
IL(rms)=451.22198193321A
LAST Step Rounding Answer
IL(rms)=451.222A

RMS Load Current of Three Phase Uncontrolled Rectifier Formula Elements

Variables
Constants
Functions
RMS Load Current
RMS load current is a measure of the effective or equivalent current flowing through a load in an alternating current (AC) circuit.
Symbol: IL(rms)
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Winding Ratio
Winding Ratio of an uncontrolled rectifier is the ratio of the number of turns on the primary winding to the number of turns on the secondary winding of the transformer.
Symbol: n
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Peak Input Voltage
Peak Input Voltage is the peak of the alternating voltage provided at the input of any electrical circuit.
Symbol: Vmax
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Load Resistance
Load Resistance of uncontrolled rectifier is a type of rectifier circuit that uses a resistive load to convert AC voltage to DC voltage.
Symbol: RL
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Full Wave category

​Go Load Voltage of Full Wave Three Phase Uncontrolled Rectifier
Vac=2nVmaxπ
​Go Average Load Current of Three Phase Uncontrolled Rectifier
IL(avg)=33nVmax2πRL
​Go Power Delivered to Load in Three Phase Uncontrolled Rectifier
Pout=VacVdc
​Go Average Diode Current of Three Phase Uncontrolled Rectifier
Id(avg)=3nVmax2πRL

How to Evaluate RMS Load Current of Three Phase Uncontrolled Rectifier?

RMS Load Current of Three Phase Uncontrolled Rectifier evaluator uses RMS Load Current = (Winding Ratio*Peak Input Voltage)/(Load Resistance*sqrt(2))*sqrt(1+(3*sqrt(3))/(2*pi)) to evaluate the RMS Load Current, RMS Load Current of Three Phase Uncontrolled Rectifier is important because it is the current that is seen by the load circuit. It is also the current that is used to calculate the power delivered to the load. The RMS value of the load current of an uncontrolled rectifier is always higher than the average load current. This is because the load current of an uncontrolled rectifier is a pulsating DC current with a ripple current superimposed on it. The ripple current is the AC component of the load current, and it is caused by the fact that the rectified sinusoidal waveform is not a pure DC waveform. RMS Load Current is denoted by IL(rms) symbol.

How to evaluate RMS Load Current of Three Phase Uncontrolled Rectifier using this online evaluator? To use this online evaluator for RMS Load Current of Three Phase Uncontrolled Rectifier, enter Winding Ratio (n), Peak Input Voltage (Vmax) & Load Resistance (RL) and hit the calculate button.

FAQs on RMS Load Current of Three Phase Uncontrolled Rectifier

What is the formula to find RMS Load Current of Three Phase Uncontrolled Rectifier?
The formula of RMS Load Current of Three Phase Uncontrolled Rectifier is expressed as RMS Load Current = (Winding Ratio*Peak Input Voltage)/(Load Resistance*sqrt(2))*sqrt(1+(3*sqrt(3))/(2*pi)). Here is an example- 451.222 = (15*220)/(6.99*sqrt(2))*sqrt(1+(3*sqrt(3))/(2*pi)).
How to calculate RMS Load Current of Three Phase Uncontrolled Rectifier?
With Winding Ratio (n), Peak Input Voltage (Vmax) & Load Resistance (RL) we can find RMS Load Current of Three Phase Uncontrolled Rectifier using the formula - RMS Load Current = (Winding Ratio*Peak Input Voltage)/(Load Resistance*sqrt(2))*sqrt(1+(3*sqrt(3))/(2*pi)). This formula also uses Archimedes' constant and Square Root (sqrt) function(s).
Can the RMS Load Current of Three Phase Uncontrolled Rectifier be negative?
No, the RMS Load Current of Three Phase Uncontrolled Rectifier, measured in Electric Current cannot be negative.
Which unit is used to measure RMS Load Current of Three Phase Uncontrolled Rectifier?
RMS Load Current of Three Phase Uncontrolled Rectifier is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which RMS Load Current of Three Phase Uncontrolled Rectifier can be measured.