RMS Load Current of Three Phase Uncontrolled Rectifier evaluator uses RMS Load Current = (Winding Ratio*Peak Input Voltage)/(Load Resistance*sqrt(2))*sqrt(1+(3*sqrt(3))/(2*pi)) to evaluate the RMS Load Current, RMS Load Current of Three Phase Uncontrolled Rectifier is important because it is the current that is seen by the load circuit. It is also the current that is used to calculate the power delivered to the load. The RMS value of the load current of an uncontrolled rectifier is always higher than the average load current. This is because the load current of an uncontrolled rectifier is a pulsating DC current with a ripple current superimposed on it. The ripple current is the AC component of the load current, and it is caused by the fact that the rectified sinusoidal waveform is not a pure DC waveform. RMS Load Current is denoted by IL(rms) symbol.
How to evaluate RMS Load Current of Three Phase Uncontrolled Rectifier using this online evaluator? To use this online evaluator for RMS Load Current of Three Phase Uncontrolled Rectifier, enter Winding Ratio (n), Peak Input Voltage (Vmax) & Load Resistance (RL) and hit the calculate button.