Rise Time Imposed by Oscilloscope Formula

Fx Copy
LaTeX Copy
Oscilloscope Imposed Rise Time is defined as step function, rise time in time taken by a signal to change from a specified low value to a specified high value imposed by oscilloscope. Check FAQs
tro=tri2-td2
tro - Oscilloscope Imposed Rise Time?tri - Input Pulse Rise Time?td - Oscilloscope Display Rise Time?

Rise Time Imposed by Oscilloscope Example

With values
With units
Only example

Here is how the Rise Time Imposed by Oscilloscope equation looks like with Values.

Here is how the Rise Time Imposed by Oscilloscope equation looks like with Units.

Here is how the Rise Time Imposed by Oscilloscope equation looks like.

8Edit=10Edit2-6Edit2
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Signal Generator and Analyzer » fx Rise Time Imposed by Oscilloscope

Rise Time Imposed by Oscilloscope Solution

Follow our step by step solution on how to calculate Rise Time Imposed by Oscilloscope?

FIRST Step Consider the formula
tro=tri2-td2
Next Step Substitute values of Variables
tro=10s2-6s2
Next Step Prepare to Evaluate
tro=102-62
LAST Step Evaluate
tro=8s

Rise Time Imposed by Oscilloscope Formula Elements

Variables
Functions
Oscilloscope Imposed Rise Time
Oscilloscope Imposed Rise Time is defined as step function, rise time in time taken by a signal to change from a specified low value to a specified high value imposed by oscilloscope.
Symbol: tro
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Input Pulse Rise Time
Input Pulse Rise Time refers to the time it takes for a signal to transition from a low level to a high level, usually measured between specified percentage points on the waveform.
Symbol: tri
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Oscilloscope Display Rise Time
Oscilloscope Display Rise Time refers to the time it takes for a signal to transition from a specified low value to a specified high value.
Symbol: td
Measurement: TimeUnit: s
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Oscilloscope category

​Go Oscillation Time Period
To=TNcn
​Go Output Time Period
T=ToNcn
​Go Modulus Number of Counter
n=log(Nc,(TTo))
​Go Time Period of Waveform
Tp=divHTdiv

How to Evaluate Rise Time Imposed by Oscilloscope?

Rise Time Imposed by Oscilloscope evaluator uses Oscilloscope Imposed Rise Time = sqrt(Input Pulse Rise Time^2-Oscilloscope Display Rise Time^2) to evaluate the Oscilloscope Imposed Rise Time, The Rise Time Imposed by Oscilloscope formula is defined as the minimum time required for the oscilloscope to accurately display the rising edge of a fast input signal. It is essentially the smallest rise time that the oscilloscope can faithfully reproduce without significant distortion or attenuation, determined by the oscilloscope's own bandwidth and response characteristics. Oscilloscope Imposed Rise Time is denoted by tro symbol.

How to evaluate Rise Time Imposed by Oscilloscope using this online evaluator? To use this online evaluator for Rise Time Imposed by Oscilloscope, enter Input Pulse Rise Time (tri) & Oscilloscope Display Rise Time (td) and hit the calculate button.

FAQs on Rise Time Imposed by Oscilloscope

What is the formula to find Rise Time Imposed by Oscilloscope?
The formula of Rise Time Imposed by Oscilloscope is expressed as Oscilloscope Imposed Rise Time = sqrt(Input Pulse Rise Time^2-Oscilloscope Display Rise Time^2). Here is an example- 8 = sqrt(10^2-6^2).
How to calculate Rise Time Imposed by Oscilloscope?
With Input Pulse Rise Time (tri) & Oscilloscope Display Rise Time (td) we can find Rise Time Imposed by Oscilloscope using the formula - Oscilloscope Imposed Rise Time = sqrt(Input Pulse Rise Time^2-Oscilloscope Display Rise Time^2). This formula also uses Square Root (sqrt) function(s).
Can the Rise Time Imposed by Oscilloscope be negative?
No, the Rise Time Imposed by Oscilloscope, measured in Time cannot be negative.
Which unit is used to measure Rise Time Imposed by Oscilloscope?
Rise Time Imposed by Oscilloscope is usually measured using the Second[s] for Time. Millisecond[s], Microsecond[s], Nanosecond[s] are the few other units in which Rise Time Imposed by Oscilloscope can be measured.
Copied!