Reynolds Number is the ratio of inertial forces to viscous forces within a fluid which is subjected to relative internal movement due to different fluid velocities. Check FAQs
Re=64f
Re - Reynolds Number?f - Friction Factor in Duct?

Reynolds Number given Friction Factor for Laminar Flow Example

With values
With units
Only example

Here is how the Reynolds Number given Friction Factor for Laminar Flow equation looks like with Values.

Here is how the Reynolds Number given Friction Factor for Laminar Flow equation looks like with Units.

Here is how the Reynolds Number given Friction Factor for Laminar Flow equation looks like.

80Edit=640.8Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Refrigeration and Air Conditioning » fx Reynolds Number given Friction Factor for Laminar Flow

Reynolds Number given Friction Factor for Laminar Flow Solution

Follow our step by step solution on how to calculate Reynolds Number given Friction Factor for Laminar Flow?

FIRST Step Consider the formula
Re=64f
Next Step Substitute values of Variables
Re=640.8
Next Step Prepare to Evaluate
Re=640.8
LAST Step Evaluate
Re=80

Reynolds Number given Friction Factor for Laminar Flow Formula Elements

Variables
Reynolds Number
Reynolds Number is the ratio of inertial forces to viscous forces within a fluid which is subjected to relative internal movement due to different fluid velocities.
Symbol: Re
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Friction Factor in Duct
Friction Factor in Duct is dimensionless number depending upon the surface of the duct.
Symbol: f
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Reynolds Number

​Go Reynolds Number in Duct
Re=dVmυ

Other formulas in Parameters of Ducts category

​Go Equivalent Diameter of Circular Duct for Rectangular Duct when Quantity of Air is Same
De=1.256(a3b3a+b)0.2
​Go Equivalent Diameter of Circular Duct for Rectangular Duct when Velocity of Air is Same
De=2aba+b
​Go Velocity Pressure in Ducts
Pv=0.6Vm2
​Go Quantity of Air given Velocity
Q=VAcs

How to Evaluate Reynolds Number given Friction Factor for Laminar Flow?

Reynolds Number given Friction Factor for Laminar Flow evaluator uses Reynolds Number = 64/Friction Factor in Duct to evaluate the Reynolds Number, Reynolds Number given Friction Factor for Laminar Flow formula is defined as a dimensionless value that characterizes the nature of fluid flow, specifically in laminar flow conditions, providing a crucial parameter in the analysis of fluid dynamics and pipe flow. Reynolds Number is denoted by Re symbol.

How to evaluate Reynolds Number given Friction Factor for Laminar Flow using this online evaluator? To use this online evaluator for Reynolds Number given Friction Factor for Laminar Flow, enter Friction Factor in Duct (f) and hit the calculate button.

FAQs on Reynolds Number given Friction Factor for Laminar Flow

What is the formula to find Reynolds Number given Friction Factor for Laminar Flow?
The formula of Reynolds Number given Friction Factor for Laminar Flow is expressed as Reynolds Number = 64/Friction Factor in Duct. Here is an example- 80 = 64/0.8.
How to calculate Reynolds Number given Friction Factor for Laminar Flow?
With Friction Factor in Duct (f) we can find Reynolds Number given Friction Factor for Laminar Flow using the formula - Reynolds Number = 64/Friction Factor in Duct.
What are the other ways to Calculate Reynolds Number?
Here are the different ways to Calculate Reynolds Number-
  • Reynolds Number=(Diameter of Circular Duct*Mean Velocity of Air)/Kinematic ViscosityOpenImg