Resistivity is the measure of how strongly a material opposes the flow of current through them. Check FAQs
ρ=VPloss(Vm(cos(Φ)))27(PL)2
ρ - Resistivity?V - Volume Of Conductor?Ploss - Line Losses?Vm - Maximum Voltage Underground AC?Φ - Phase Difference?P - Power Transmitted?L - Length of Underground AC Wire?

Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) Example

With values
With units
Only example

Here is how the Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) equation looks like with Values.

Here is how the Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) equation looks like with Units.

Here is how the Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) equation looks like.

0.0175Edit=60Edit2.67Edit(230Edit(cos(30Edit)))27(300Edit24Edit)2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Resistivity using Volume of Conductor Material (3 Phase 3 Wire US)

Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) Solution

Follow our step by step solution on how to calculate Resistivity using Volume of Conductor Material (3 Phase 3 Wire US)?

FIRST Step Consider the formula
ρ=VPloss(Vm(cos(Φ)))27(PL)2
Next Step Substitute values of Variables
ρ=602.67W(230V(cos(30°)))27(300W24m)2
Next Step Convert Units
ρ=602.67W(230V(cos(0.5236rad)))27(300W24m)2
Next Step Prepare to Evaluate
ρ=602.67(230(cos(0.5236)))27(30024)2
Next Step Evaluate
ρ=0.0175152529761905Ω*m
LAST Step Rounding Answer
ρ=0.0175Ω*m

Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) Formula Elements

Variables
Functions
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage Underground AC
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Resistivity

​Go Resistivity using Area of X-Section (3 Phase 3 Wire US)
ρ=APloss(Vm2)cos(Φ)22(P2)L

Other formulas in Resistance and Resistivity category

​Go Resistance using Line Losses (3 Phase 3 Wire US)
R=Ploss3(I2)
​Go Angle of PF using Volume of Conductor Material (3 Phase 3 Wire US)
Φ=acos((0.5)KV)

How to Evaluate Resistivity using Volume of Conductor Material (3 Phase 3 Wire US)?

Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) evaluator uses Resistivity = Volume Of Conductor*Line Losses*(Maximum Voltage Underground AC*(cos(Phase Difference)))^2/(7*(Power Transmitted*Length of Underground AC Wire)^2) to evaluate the Resistivity, The Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) formula is defined as a characteristic property of each material, resistivity is useful in comparing various materials on the basis of their ability to conduct electric currents. High resistivity designates poor conductors. Resistivity is denoted by ρ symbol.

How to evaluate Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) using this online evaluator? To use this online evaluator for Resistivity using Volume of Conductor Material (3 Phase 3 Wire US), enter Volume Of Conductor (V), Line Losses (Ploss), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Power Transmitted (P) & Length of Underground AC Wire (L) and hit the calculate button.

FAQs on Resistivity using Volume of Conductor Material (3 Phase 3 Wire US)

What is the formula to find Resistivity using Volume of Conductor Material (3 Phase 3 Wire US)?
The formula of Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) is expressed as Resistivity = Volume Of Conductor*Line Losses*(Maximum Voltage Underground AC*(cos(Phase Difference)))^2/(7*(Power Transmitted*Length of Underground AC Wire)^2). Here is an example- 0.017515 = 60*2.67*(230*(cos(0.5235987755982)))^2/(7*(300*24)^2).
How to calculate Resistivity using Volume of Conductor Material (3 Phase 3 Wire US)?
With Volume Of Conductor (V), Line Losses (Ploss), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Power Transmitted (P) & Length of Underground AC Wire (L) we can find Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) using the formula - Resistivity = Volume Of Conductor*Line Losses*(Maximum Voltage Underground AC*(cos(Phase Difference)))^2/(7*(Power Transmitted*Length of Underground AC Wire)^2). This formula also uses Cosine (cos) function(s).
What are the other ways to Calculate Resistivity?
Here are the different ways to Calculate Resistivity-
  • Resistivity=Area of Underground AC Wire*Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2)/(2*(Power Transmitted^2)*Length of Underground AC Wire)OpenImg
Can the Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) be negative?
Yes, the Resistivity using Volume of Conductor Material (3 Phase 3 Wire US), measured in Electric Resistivity can be negative.
Which unit is used to measure Resistivity using Volume of Conductor Material (3 Phase 3 Wire US)?
Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) is usually measured using the Ohm Meter[Ω*m] for Electric Resistivity. Ohm Centimeter[Ω*m], Ohm Inch[Ω*m], Microhm Centimeter[Ω*m] are the few other units in which Resistivity using Volume of Conductor Material (3 Phase 3 Wire US) can be measured.