Fx Copy
LaTeX Copy
Resistivity is the measure of how strongly a material opposes the flow of current through them. Check FAQs
ρ=(VPline4(C12)(l2))
ρ - Resistivity?V - Volume Of Conductor?Pline - Line Losses?C1 - Current underground DC?l - Length of Wire DC?

Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) Example

With values
With units
Only example

Here is how the Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) equation looks like with Values.

Here is how the Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) equation looks like with Units.

Here is how the Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) equation looks like.

0.057Edit=(35Edit0.6Edit4(3Edit2)(3.2Edit2))
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US)

Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) Solution

Follow our step by step solution on how to calculate Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US)?

FIRST Step Consider the formula
ρ=(VPline4(C12)(l2))
Next Step Substitute values of Variables
ρ=(350.6W4(3A2)(3.2m2))
Next Step Prepare to Evaluate
ρ=(350.64(32)(3.22))
Next Step Evaluate
ρ=0.0569661458333333Ω*m
LAST Step Rounding Answer
ρ=0.057Ω*m

Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) Formula Elements

Variables
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the losses that are produced in the line.
Symbol: Pline
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current underground DC
Current underground DC is defined as the current flowing through the overhead ac supply wire.
Symbol: C1
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Length of Wire DC
Length of Wire DC is the measurement or extent of something from end to end.
Symbol: l
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Resistivity

​Go Resistivity using Area of X-Section (2-wire Mid-point earthed DC US)
ρ=APlineVm22(P2)l

Other formulas in Power and Resistivity category

​Go Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US)
P=APlineVm22ρl
​Go Power Transmitted using Volume of Conductor Material (2-Wire Mid-Point DC US)
P=VPlineVm24ρ(l2)
​Go Power Transmitted using Load Current (2-Wire Mid-Point DC US)
P=C1Vm

How to Evaluate Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US)?

Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) evaluator uses Resistivity = (Volume Of Conductor*Line Losses/(4*(Current underground DC^2)*(Length of Wire DC^2))) to evaluate the Resistivity, The Resistivity using Volume of Conductor Material (2-wire Mid-point DC US) formula is defined as a characteristic property of each material, resistivity is useful in comparing various materials on the basis of their ability to conduct electric currents. High resistivity designates poor conductors. Resistivity is denoted by ρ symbol.

How to evaluate Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) using this online evaluator? To use this online evaluator for Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US), enter Volume Of Conductor (V), Line Losses (Pline), Current underground DC (C1) & Length of Wire DC (l) and hit the calculate button.

FAQs on Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US)

What is the formula to find Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US)?
The formula of Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) is expressed as Resistivity = (Volume Of Conductor*Line Losses/(4*(Current underground DC^2)*(Length of Wire DC^2))). Here is an example- 0.056966 = (35*0.6/(4*(3^2)*(3.2^2))).
How to calculate Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US)?
With Volume Of Conductor (V), Line Losses (Pline), Current underground DC (C1) & Length of Wire DC (l) we can find Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) using the formula - Resistivity = (Volume Of Conductor*Line Losses/(4*(Current underground DC^2)*(Length of Wire DC^2))).
What are the other ways to Calculate Resistivity?
Here are the different ways to Calculate Resistivity-
  • Resistivity=Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*(Power Transmitted^2)*Length of Wire DC)OpenImg
Can the Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) be negative?
Yes, the Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US), measured in Electric Resistivity can be negative.
Which unit is used to measure Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US)?
Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) is usually measured using the Ohm Meter[Ω*m] for Electric Resistivity. Ohm Centimeter[Ω*m], Ohm Inch[Ω*m], Microhm Centimeter[Ω*m] are the few other units in which Resistivity using Volume of Conductor Material (2-Wire Mid-Point DC US) can be measured.
Copied!