Fx Copy
LaTeX Copy
Resistivity is the measure of how strongly a material opposes the flow of current through them. Check FAQs
ρ=R2AL
ρ - Resistivity?R - Resistance Underground AC?A - Area of Underground AC Wire?L - Length of Underground AC Wire?

Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) Example

With values
With units
Only example

Here is how the Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) equation looks like with Values.

Here is how the Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) equation looks like with Units.

Here is how the Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) equation looks like.

0.3771Edit=5Edit21.28Edit24Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US)

Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) Solution

Follow our step by step solution on how to calculate Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US)?

FIRST Step Consider the formula
ρ=R2AL
Next Step Substitute values of Variables
ρ=5Ω21.2824m
Next Step Prepare to Evaluate
ρ=521.2824
Next Step Evaluate
ρ=0.377123616632825Ω*m
LAST Step Rounding Answer
ρ=0.3771Ω*m

Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) Formula Elements

Variables
Functions
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Resistivity

​Go Resistivity using Volume of Conductor Material (2 Phase 3 Wire US)
ρ=VPloss(Vm(cos(Φ)))2((2+2)PL)2
​Go Resistivity using Line Losses (2-Phase 3-Wire US)
ρ=PlossA(Vmcos(Φ))2(2+2)(P)2L

Other formulas in Resistance and Resistivity category

​Go Resistance using Line Losses (2-Phase 3-Wire US)
R=Ploss(2+2)(I)2
​Go Resistance of Neutral Wire (2-Phase 3-Wire US)
Rneutral=R2

How to Evaluate Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US)?

Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) evaluator uses Resistivity = Resistance Underground AC*sqrt(2)*Area of Underground AC Wire/(Length of Underground AC Wire) to evaluate the Resistivity, The Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) formula is defined as a characteristic property of each material, resistivity is useful in comparing various materials on the basis of their ability to conduct electric currents. High resistivity designates poor conductors. Resistivity is denoted by ρ symbol.

How to evaluate Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) using this online evaluator? To use this online evaluator for Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US), enter Resistance Underground AC (R), Area of Underground AC Wire (A) & Length of Underground AC Wire (L) and hit the calculate button.

FAQs on Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US)

What is the formula to find Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US)?
The formula of Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) is expressed as Resistivity = Resistance Underground AC*sqrt(2)*Area of Underground AC Wire/(Length of Underground AC Wire). Here is an example- 0.377124 = 5*sqrt(2)*1.28/(24).
How to calculate Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US)?
With Resistance Underground AC (R), Area of Underground AC Wire (A) & Length of Underground AC Wire (L) we can find Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) using the formula - Resistivity = Resistance Underground AC*sqrt(2)*Area of Underground AC Wire/(Length of Underground AC Wire). This formula also uses Square Root Function function(s).
What are the other ways to Calculate Resistivity?
Here are the different ways to Calculate Resistivity-
  • Resistivity=Volume Of Conductor*Line Losses*(Maximum Voltage Underground AC*(cos(Phase Difference)))^2/(((2+sqrt(2))*Power Transmitted*Length of Underground AC Wire)^2)OpenImg
  • Resistivity=Line Losses*Area of Underground AC Wire*(Maximum Voltage Underground AC*cos(Phase Difference))^2/((2+sqrt(2))*(Power Transmitted)^2*Length of Underground AC Wire)OpenImg
Can the Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) be negative?
Yes, the Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US), measured in Electric Resistivity can be negative.
Which unit is used to measure Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US)?
Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) is usually measured using the Ohm Meter[Ω*m] for Electric Resistivity. Ohm Centimeter[Ω*m], Ohm Inch[Ω*m], Microhm Centimeter[Ω*m] are the few other units in which Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US) can be measured.
Copied!