Resistivity is the measure of how strongly a material opposes the flow of current through them. Check FAQs
ρ=APloss2(I2)L
ρ - Resistivity?A - Area of Underground AC Wire?Ploss - Line Losses?I - Current Underground AC?L - Length of Underground AC Wire?

Resistivity using Load Current (2 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the Resistivity using Load Current (2 Phase 4 Wire US) equation looks like with Values.

Here is how the Resistivity using Load Current (2 Phase 4 Wire US) equation looks like with Units.

Here is how the Resistivity using Load Current (2 Phase 4 Wire US) equation looks like.

0.0009Edit=1.28Edit2.67Edit2(9Edit2)24Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Resistivity using Load Current (2 Phase 4 Wire US)

Resistivity using Load Current (2 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate Resistivity using Load Current (2 Phase 4 Wire US)?

FIRST Step Consider the formula
ρ=APloss2(I2)L
Next Step Substitute values of Variables
ρ=1.282.67W2(9A2)24m
Next Step Prepare to Evaluate
ρ=1.282.672(92)24
Next Step Evaluate
ρ=0.000879012345679012Ω*m
LAST Step Rounding Answer
ρ=0.0009Ω*m

Resistivity using Load Current (2 Phase 4 Wire US) Formula Elements

Variables
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Resistivity

​Go Resistivity using Line Losses (2 Phase 4 Wire US)
ρ=PlossA2(I2)L
​Go Resistivity using Area of X-Section (2 Phase 4 Wire US)
ρ=APloss(Vm2)cos(Φ)24L(P2)
​Go Resistivity using Volume of Conductor Material (2 Phase 4 Wire US)
ρ=VPloss4((IL)2)

Other formulas in Resistance and Resistivity category

​Go Resistance using Line Losses (2 Phase 4 Wire US)
R=Ploss2(I2)

How to Evaluate Resistivity using Load Current (2 Phase 4 Wire US)?

Resistivity using Load Current (2 Phase 4 Wire US) evaluator uses Resistivity = Area of Underground AC Wire*Line Losses/(2*(Current Underground AC^2)*Length of Underground AC Wire) to evaluate the Resistivity, The Resistivity using Load Current (2 phase 4 wire US) formula is defined as a characteristic property of each material, resistivity is useful in comparing various materials on the basis of their ability to conduct electric currents. High resistivity designates poor conductors. Resistivity is denoted by ρ symbol.

How to evaluate Resistivity using Load Current (2 Phase 4 Wire US) using this online evaluator? To use this online evaluator for Resistivity using Load Current (2 Phase 4 Wire US), enter Area of Underground AC Wire (A), Line Losses (Ploss), Current Underground AC (I) & Length of Underground AC Wire (L) and hit the calculate button.

FAQs on Resistivity using Load Current (2 Phase 4 Wire US)

What is the formula to find Resistivity using Load Current (2 Phase 4 Wire US)?
The formula of Resistivity using Load Current (2 Phase 4 Wire US) is expressed as Resistivity = Area of Underground AC Wire*Line Losses/(2*(Current Underground AC^2)*Length of Underground AC Wire). Here is an example- 0.000879 = 1.28*2.67/(2*(9^2)*24).
How to calculate Resistivity using Load Current (2 Phase 4 Wire US)?
With Area of Underground AC Wire (A), Line Losses (Ploss), Current Underground AC (I) & Length of Underground AC Wire (L) we can find Resistivity using Load Current (2 Phase 4 Wire US) using the formula - Resistivity = Area of Underground AC Wire*Line Losses/(2*(Current Underground AC^2)*Length of Underground AC Wire).
What are the other ways to Calculate Resistivity?
Here are the different ways to Calculate Resistivity-
  • Resistivity=Line Losses*Area of Underground AC Wire/(2*(Current Underground AC^2)*Length of Underground AC Wire)OpenImg
  • Resistivity=Area of Underground AC Wire*Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2)/(4*Length of Underground AC Wire*(Power Transmitted^2))OpenImg
  • Resistivity=Volume Of Conductor*Line Losses/(4*((Current Underground AC*Length of Underground AC Wire)^2))OpenImg
Can the Resistivity using Load Current (2 Phase 4 Wire US) be negative?
Yes, the Resistivity using Load Current (2 Phase 4 Wire US), measured in Electric Resistivity can be negative.
Which unit is used to measure Resistivity using Load Current (2 Phase 4 Wire US)?
Resistivity using Load Current (2 Phase 4 Wire US) is usually measured using the Ohm Meter[Ω*m] for Electric Resistivity. Ohm Centimeter[Ω*m], Ohm Inch[Ω*m], Microhm Centimeter[Ω*m] are the few other units in which Resistivity using Load Current (2 Phase 4 Wire US) can be measured.
Copied!