Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it. Check FAQs
R=VPloss(Vm2)cos(Φ)27(P2)A
R - Resistance Underground AC?V - Volume Of Conductor?Ploss - Line Losses?Vm - Maximum Voltage Underground AC?Φ - Phase Difference?P - Power Transmitted?A - Area of Underground AC Wire?

Resistance using Volume of Conductor Material (3 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the Resistance using Volume of Conductor Material (3 Phase 4 Wire US) equation looks like with Values.

Here is how the Resistance using Volume of Conductor Material (3 Phase 4 Wire US) equation looks like with Units.

Here is how the Resistance using Volume of Conductor Material (3 Phase 4 Wire US) equation looks like.

7.8819Edit=60Edit2.67Edit(230Edit2)cos(30Edit)27(300Edit2)1.28Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Resistance using Volume of Conductor Material (3 Phase 4 Wire US)

Resistance using Volume of Conductor Material (3 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate Resistance using Volume of Conductor Material (3 Phase 4 Wire US)?

FIRST Step Consider the formula
R=VPloss(Vm2)cos(Φ)27(P2)A
Next Step Substitute values of Variables
R=602.67W(230V2)cos(30°)27(300W2)1.28
Next Step Convert Units
R=602.67W(230V2)cos(0.5236rad)27(300W2)1.28
Next Step Prepare to Evaluate
R=602.67(2302)cos(0.5236)27(3002)1.28
Next Step Evaluate
R=7.88186383928571Ω
LAST Step Rounding Answer
R=7.8819Ω

Resistance using Volume of Conductor Material (3 Phase 4 Wire US) Formula Elements

Variables
Functions
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage Underground AC
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Resistance Underground AC

​Go Resistance using Line Losses (3 Phase 4 Wire US)
R=Ploss3(I2)

Other formulas in Resistance and Resistivity category

​Go Resistivity using Volume of Conductor Material (3 Phase 4 Wire US)
ρ=VPloss(Vm(cos(Φ)))26(PL)2
​Go Resistivity using Area of X-Section (3 Phase 4 Wire US)
ρ=APloss(Vm2)cos(Φ)24L(P2)

How to Evaluate Resistance using Volume of Conductor Material (3 Phase 4 Wire US)?

Resistance using Volume of Conductor Material (3 Phase 4 Wire US) evaluator uses Resistance Underground AC = Volume Of Conductor*Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2)/(7*(Power Transmitted^2)*Area of Underground AC Wire) to evaluate the Resistance Underground AC, The Resistance using Volume of Conductor Material (3 phase 4 wire US) formula is defined as a measure of the opposition to current flow in an electrical circuit. Resistance Underground AC is denoted by R symbol.

How to evaluate Resistance using Volume of Conductor Material (3 Phase 4 Wire US) using this online evaluator? To use this online evaluator for Resistance using Volume of Conductor Material (3 Phase 4 Wire US), enter Volume Of Conductor (V), Line Losses (Ploss), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Power Transmitted (P) & Area of Underground AC Wire (A) and hit the calculate button.

FAQs on Resistance using Volume of Conductor Material (3 Phase 4 Wire US)

What is the formula to find Resistance using Volume of Conductor Material (3 Phase 4 Wire US)?
The formula of Resistance using Volume of Conductor Material (3 Phase 4 Wire US) is expressed as Resistance Underground AC = Volume Of Conductor*Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2)/(7*(Power Transmitted^2)*Area of Underground AC Wire). Here is an example- 7.881864 = 60*2.67*(230^2)*(cos(0.5235987755982)^2)/(7*(300^2)*1.28).
How to calculate Resistance using Volume of Conductor Material (3 Phase 4 Wire US)?
With Volume Of Conductor (V), Line Losses (Ploss), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Power Transmitted (P) & Area of Underground AC Wire (A) we can find Resistance using Volume of Conductor Material (3 Phase 4 Wire US) using the formula - Resistance Underground AC = Volume Of Conductor*Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2)/(7*(Power Transmitted^2)*Area of Underground AC Wire). This formula also uses Cosine (cos) function(s).
What are the other ways to Calculate Resistance Underground AC?
Here are the different ways to Calculate Resistance Underground AC-
  • Resistance Underground AC=Line Losses/(3*(Current Underground AC^2))OpenImg
Can the Resistance using Volume of Conductor Material (3 Phase 4 Wire US) be negative?
Yes, the Resistance using Volume of Conductor Material (3 Phase 4 Wire US), measured in Electric Resistance can be negative.
Which unit is used to measure Resistance using Volume of Conductor Material (3 Phase 4 Wire US)?
Resistance using Volume of Conductor Material (3 Phase 4 Wire US) is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Resistance using Volume of Conductor Material (3 Phase 4 Wire US) can be measured.