Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it. Check FAQs
R=Ploss2(I)2
R - Resistance Overhead AC?Ploss - Line Losses?I - Current Overhead AC?

Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) Example

With values
With units
Only example

Here is how the Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) equation looks like with Values.

Here is how the Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) equation looks like with Units.

Here is how the Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) equation looks like.

0.0864Edit=8.23Edit2(6.9Edit)2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS)

Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) Solution

Follow our step by step solution on how to calculate Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS)?

FIRST Step Consider the formula
R=Ploss2(I)2
Next Step Substitute values of Variables
R=8.23W2(6.9A)2
Next Step Prepare to Evaluate
R=8.232(6.9)2
Next Step Evaluate
R=0.0864314219701743Ω
LAST Step Rounding Answer
R=0.0864Ω

Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) Formula Elements

Variables
Resistance Overhead AC
Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Overhead AC
Current Overhead AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other Formulas to find Resistance Overhead AC

​Go Resistance(Single-Phase Two-Wire Mid-Point Earthed OS)
R=ρLA
​Go Resistance using Line Losses (Single-Phase Two-Wire Mid-Point OS)
R=Ploss(Vmcos(Φ))2(P)2

Other formulas in Resistance and Resistivity category

​Go Resistivity using Area of X-Section(Single-Phase Two-Wire Mid-Point Earthed OS)
ρ=AVm2Ploss(cos(Φ))2LP2
​Go Resistivity using Load Current (Single-Phase Two-Wire Mid-Point OS)
ρ=PlossA2(I)2L

How to Evaluate Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS)?

Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) evaluator uses Resistance Overhead AC = Line Losses/(2*(Current Overhead AC)^2) to evaluate the Resistance Overhead AC, Resistance using Load Current (single-Phase two-Wire Mid-Point OS) formula is defined as a measure of the opposition to current flow in an electrical circuit. Resistance Overhead AC is denoted by R symbol.

How to evaluate Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) using this online evaluator? To use this online evaluator for Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS), enter Line Losses (Ploss) & Current Overhead AC (I) and hit the calculate button.

FAQs on Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS)

What is the formula to find Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS)?
The formula of Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) is expressed as Resistance Overhead AC = Line Losses/(2*(Current Overhead AC)^2). Here is an example- 0.086431 = 8.23/(2*(6.9)^2).
How to calculate Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS)?
With Line Losses (Ploss) & Current Overhead AC (I) we can find Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) using the formula - Resistance Overhead AC = Line Losses/(2*(Current Overhead AC)^2).
What are the other ways to Calculate Resistance Overhead AC?
Here are the different ways to Calculate Resistance Overhead AC-
  • Resistance Overhead AC=(Resistivity*Length of Overhead AC Wire)/Area of Overhead AC WireOpenImg
  • Resistance Overhead AC=(Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2)/((Power Transmitted)^2)OpenImg
Can the Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) be negative?
Yes, the Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS), measured in Electric Resistance can be negative.
Which unit is used to measure Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS)?
Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Resistance using Load Current (Single-Phase Two-Wire Mid-Point OS) can be measured.
Copied!