Fx Copy
LaTeX Copy
Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it. Check FAQs
R=Ploss(2+2)(I)2
R - Resistance Overhead AC?Ploss - Line Losses?I - Current Overhead AC?

Resistance using Line Losses (Two-Phase Three-Wire OS) Example

With values
With units
Only example

Here is how the Resistance using Line Losses (Two-Phase Three-Wire OS) equation looks like with Values.

Here is how the Resistance using Line Losses (Two-Phase Three-Wire OS) equation looks like with Units.

Here is how the Resistance using Line Losses (Two-Phase Three-Wire OS) equation looks like.

0.0506Edit=8.23Edit(2+2)(6.9Edit)2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Resistance using Line Losses (Two-Phase Three-Wire OS)

Resistance using Line Losses (Two-Phase Three-Wire OS) Solution

Follow our step by step solution on how to calculate Resistance using Line Losses (Two-Phase Three-Wire OS)?

FIRST Step Consider the formula
R=Ploss(2+2)(I)2
Next Step Substitute values of Variables
R=8.23W(2+2)(6.9A)2
Next Step Prepare to Evaluate
R=8.23(2+2)(6.9)2
Next Step Evaluate
R=0.0506303547749362Ω
LAST Step Rounding Answer
R=0.0506Ω

Resistance using Line Losses (Two-Phase Three-Wire OS) Formula Elements

Variables
Functions
Resistance Overhead AC
Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Overhead AC
Current Overhead AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Resistance Overhead AC

​Go Resistance(Two-Phase Three-Wire OS)
R=ρLA

Other formulas in Resistance and Resistivity category

​Go Resistivity using Area of X-Section(Two-Phase Three-Wire OS)
ρ=2A(Vm2)Ploss((cos(Φ))2)(2+2)L(P2)
​Go Resistivity using Volume of Conductor Material (Two-Phase Three-Wire OS)
ρ=VPloss(Vm(cos(Φ)))2((2+1)PL)2
​Go Resistivity using Line Losses (Two-Phase Three-Wire OS)
ρ=2PlossA(Vmcos(Φ))2(2+2)(P)2L
​Go Resistivity using Resistance (Two-Phase Three-Wire OS)
ρ=RA2L

How to Evaluate Resistance using Line Losses (Two-Phase Three-Wire OS)?

Resistance using Line Losses (Two-Phase Three-Wire OS) evaluator uses Resistance Overhead AC = Line Losses/((2+sqrt(2))*(Current Overhead AC)^2) to evaluate the Resistance Overhead AC, The Resistance using Line Losses (two-phase three-wire OS) formula is defined as a measure of the opposition to current flow in an electrical circuit. Resistance Overhead AC is denoted by R symbol.

How to evaluate Resistance using Line Losses (Two-Phase Three-Wire OS) using this online evaluator? To use this online evaluator for Resistance using Line Losses (Two-Phase Three-Wire OS), enter Line Losses (Ploss) & Current Overhead AC (I) and hit the calculate button.

FAQs on Resistance using Line Losses (Two-Phase Three-Wire OS)

What is the formula to find Resistance using Line Losses (Two-Phase Three-Wire OS)?
The formula of Resistance using Line Losses (Two-Phase Three-Wire OS) is expressed as Resistance Overhead AC = Line Losses/((2+sqrt(2))*(Current Overhead AC)^2). Here is an example- 0.05063 = 8.23/((2+sqrt(2))*(6.9)^2).
How to calculate Resistance using Line Losses (Two-Phase Three-Wire OS)?
With Line Losses (Ploss) & Current Overhead AC (I) we can find Resistance using Line Losses (Two-Phase Three-Wire OS) using the formula - Resistance Overhead AC = Line Losses/((2+sqrt(2))*(Current Overhead AC)^2). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Resistance Overhead AC?
Here are the different ways to Calculate Resistance Overhead AC-
  • Resistance Overhead AC=Resistivity*Length of Overhead AC Wire/Area of Overhead AC WireOpenImg
Can the Resistance using Line Losses (Two-Phase Three-Wire OS) be negative?
Yes, the Resistance using Line Losses (Two-Phase Three-Wire OS), measured in Electric Resistance can be negative.
Which unit is used to measure Resistance using Line Losses (Two-Phase Three-Wire OS)?
Resistance using Line Losses (Two-Phase Three-Wire OS) is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Resistance using Line Losses (Two-Phase Three-Wire OS) can be measured.
Copied!