Resistance using Line Losses (2 Phase 4 Wire US) Formula

Fx Copy
LaTeX Copy
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it. Check FAQs
R=Ploss2(I2)
R - Resistance Underground AC?Ploss - Line Losses?I - Current Underground AC?

Resistance using Line Losses (2 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the Resistance using Line Losses (2 Phase 4 Wire US) equation looks like with Values.

Here is how the Resistance using Line Losses (2 Phase 4 Wire US) equation looks like with Units.

Here is how the Resistance using Line Losses (2 Phase 4 Wire US) equation looks like.

0.0165Edit=2.67Edit2(9Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Resistance using Line Losses (2 Phase 4 Wire US)

Resistance using Line Losses (2 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate Resistance using Line Losses (2 Phase 4 Wire US)?

FIRST Step Consider the formula
R=Ploss2(I2)
Next Step Substitute values of Variables
R=2.67W2(9A2)
Next Step Prepare to Evaluate
R=2.672(92)
Next Step Evaluate
R=0.0164814814814815Ω
LAST Step Rounding Answer
R=0.0165Ω

Resistance using Line Losses (2 Phase 4 Wire US) Formula Elements

Variables
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other formulas in Resistance and Resistivity category

​Go Resistivity using Line Losses (2 Phase 4 Wire US)
ρ=PlossA2(I2)L
​Go Resistivity using Area of X-Section (2 Phase 4 Wire US)
ρ=APloss(Vm2)cos(Φ)24L(P2)
​Go Resistivity using Volume of Conductor Material (2 Phase 4 Wire US)
ρ=VPloss4((IL)2)
​Go Resistivity using Load Current (2 Phase 4 Wire US)
ρ=APloss2(I2)L

How to Evaluate Resistance using Line Losses (2 Phase 4 Wire US)?

Resistance using Line Losses (2 Phase 4 Wire US) evaluator uses Resistance Underground AC = Line Losses/(2*(Current Underground AC^2)) to evaluate the Resistance Underground AC, The Resistance using Line Losses (2 phase 4 wire US) formula is defined as a measure of the opposition to current flow in an electrical circuit. Resistance Underground AC is denoted by R symbol.

How to evaluate Resistance using Line Losses (2 Phase 4 Wire US) using this online evaluator? To use this online evaluator for Resistance using Line Losses (2 Phase 4 Wire US), enter Line Losses (Ploss) & Current Underground AC (I) and hit the calculate button.

FAQs on Resistance using Line Losses (2 Phase 4 Wire US)

What is the formula to find Resistance using Line Losses (2 Phase 4 Wire US)?
The formula of Resistance using Line Losses (2 Phase 4 Wire US) is expressed as Resistance Underground AC = Line Losses/(2*(Current Underground AC^2)). Here is an example- 0.016481 = 2.67/(2*(9^2)).
How to calculate Resistance using Line Losses (2 Phase 4 Wire US)?
With Line Losses (Ploss) & Current Underground AC (I) we can find Resistance using Line Losses (2 Phase 4 Wire US) using the formula - Resistance Underground AC = Line Losses/(2*(Current Underground AC^2)).
Can the Resistance using Line Losses (2 Phase 4 Wire US) be negative?
Yes, the Resistance using Line Losses (2 Phase 4 Wire US), measured in Electric Resistance can be negative.
Which unit is used to measure Resistance using Line Losses (2 Phase 4 Wire US)?
Resistance using Line Losses (2 Phase 4 Wire US) is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Resistance using Line Losses (2 Phase 4 Wire US) can be measured.
Copied!