Resistance using Line Losses (2-Phase 3-Wire US) Formula

Fx Copy
LaTeX Copy
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it. Check FAQs
R=Ploss(2+2)(I)2
R - Resistance Underground AC?Ploss - Line Losses?I - Current Underground AC?

Resistance using Line Losses (2-Phase 3-Wire US) Example

With values
With units
Only example

Here is how the Resistance using Line Losses (2-Phase 3-Wire US) equation looks like with Values.

Here is how the Resistance using Line Losses (2-Phase 3-Wire US) equation looks like with Units.

Here is how the Resistance using Line Losses (2-Phase 3-Wire US) equation looks like.

0.0097Edit=2.67Edit(2+2)(9Edit)2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Resistance using Line Losses (2-Phase 3-Wire US)

Resistance using Line Losses (2-Phase 3-Wire US) Solution

Follow our step by step solution on how to calculate Resistance using Line Losses (2-Phase 3-Wire US)?

FIRST Step Consider the formula
R=Ploss(2+2)(I)2
Next Step Substitute values of Variables
R=2.67W(2+2)(9A)2
Next Step Prepare to Evaluate
R=2.67(2+2)(9)2
Next Step Evaluate
R=0.00965462832385084Ω
LAST Step Rounding Answer
R=0.0097Ω

Resistance using Line Losses (2-Phase 3-Wire US) Formula Elements

Variables
Functions
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Resistance and Resistivity category

​Go Resistivity using Volume of Conductor Material (2 Phase 3 Wire US)
ρ=VPloss(Vm(cos(Φ)))2((2+2)PL)2
​Go Resistivity using Line Losses (2-Phase 3-Wire US)
ρ=PlossA(Vmcos(Φ))2(2+2)(P)2L
​Go Resistance of Neutral Wire (2-Phase 3-Wire US)
Rneutral=R2
​Go Resistivity using Resistance of Natural Wire (2-Phase 3-Wire US)
ρ=R2AL

How to Evaluate Resistance using Line Losses (2-Phase 3-Wire US)?

Resistance using Line Losses (2-Phase 3-Wire US) evaluator uses Resistance Underground AC = Line Losses/((2+sqrt(2))*(Current Underground AC)^2) to evaluate the Resistance Underground AC, The Resistance using Line Losses (2-Phase 3-Wire US) formula is defined as a measure of the opposition to current flow in an electrical circuit. Resistance Underground AC is denoted by R symbol.

How to evaluate Resistance using Line Losses (2-Phase 3-Wire US) using this online evaluator? To use this online evaluator for Resistance using Line Losses (2-Phase 3-Wire US), enter Line Losses (Ploss) & Current Underground AC (I) and hit the calculate button.

FAQs on Resistance using Line Losses (2-Phase 3-Wire US)

What is the formula to find Resistance using Line Losses (2-Phase 3-Wire US)?
The formula of Resistance using Line Losses (2-Phase 3-Wire US) is expressed as Resistance Underground AC = Line Losses/((2+sqrt(2))*(Current Underground AC)^2). Here is an example- 0.009655 = 2.67/((2+sqrt(2))*(9)^2).
How to calculate Resistance using Line Losses (2-Phase 3-Wire US)?
With Line Losses (Ploss) & Current Underground AC (I) we can find Resistance using Line Losses (2-Phase 3-Wire US) using the formula - Resistance Underground AC = Line Losses/((2+sqrt(2))*(Current Underground AC)^2). This formula also uses Square Root (sqrt) function(s).
Can the Resistance using Line Losses (2-Phase 3-Wire US) be negative?
Yes, the Resistance using Line Losses (2-Phase 3-Wire US), measured in Electric Resistance can be negative.
Which unit is used to measure Resistance using Line Losses (2-Phase 3-Wire US)?
Resistance using Line Losses (2-Phase 3-Wire US) is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Resistance using Line Losses (2-Phase 3-Wire US) can be measured.
Copied!