Resistance of Secondary Winding in Primary Formula

Fx Copy
LaTeX Copy
Resistance of Secondary in Primary is the Resistance of Secondary winding in the primary. Check FAQs
R'2=R2K2
R'2 - Resistance of Secondary in Primary?R2 - Resistance of Secondary?K - Transformation Ratio?

Resistance of Secondary Winding in Primary Example

With values
With units
Only example

Here is how the Resistance of Secondary Winding in Primary equation looks like with Values.

Here is how the Resistance of Secondary Winding in Primary equation looks like with Units.

Here is how the Resistance of Secondary Winding in Primary equation looks like.

17.9861Edit=25.9Edit1.2Edit2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Resistance of Secondary Winding in Primary

Resistance of Secondary Winding in Primary Solution

Follow our step by step solution on how to calculate Resistance of Secondary Winding in Primary?

FIRST Step Consider the formula
R'2=R2K2
Next Step Substitute values of Variables
R'2=25.9Ω1.22
Next Step Prepare to Evaluate
R'2=25.91.22
Next Step Evaluate
R'2=17.9861111111111Ω
LAST Step Rounding Answer
R'2=17.9861Ω

Resistance of Secondary Winding in Primary Formula Elements

Variables
Resistance of Secondary in Primary
Resistance of Secondary in Primary is the Resistance of Secondary winding in the primary.
Symbol: R'2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Resistance of Secondary
Resistance of Secondary Winding is the resistance of secondary winding.
Symbol: R2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Transformation Ratio
The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Resistance category

​Go Equivalent Reactance of Transformer from Primary Side
X01=XL1+X'2
​Go Equivalent Reactance of Transformer from Secondary Side
X02=XL2+X'1
​Go Primary Leakage Reactance
XL1=X'1K2
​Go Reactance of Primary Winding in Secondary
X'1=XL1K2

How to Evaluate Resistance of Secondary Winding in Primary?

Resistance of Secondary Winding in Primary evaluator uses Resistance of Secondary in Primary = Resistance of Secondary/Transformation Ratio^2 to evaluate the Resistance of Secondary in Primary, The Resistance of Secondary Winding in Primary formula is defined as the resistance of the secondary winding in the primary winding. Resistance of Secondary in Primary is denoted by R'2 symbol.

How to evaluate Resistance of Secondary Winding in Primary using this online evaluator? To use this online evaluator for Resistance of Secondary Winding in Primary, enter Resistance of Secondary (R2) & Transformation Ratio (K) and hit the calculate button.

FAQs on Resistance of Secondary Winding in Primary

What is the formula to find Resistance of Secondary Winding in Primary?
The formula of Resistance of Secondary Winding in Primary is expressed as Resistance of Secondary in Primary = Resistance of Secondary/Transformation Ratio^2. Here is an example- 17.98611 = 25.9/1.2^2.
How to calculate Resistance of Secondary Winding in Primary?
With Resistance of Secondary (R2) & Transformation Ratio (K) we can find Resistance of Secondary Winding in Primary using the formula - Resistance of Secondary in Primary = Resistance of Secondary/Transformation Ratio^2.
Can the Resistance of Secondary Winding in Primary be negative?
Yes, the Resistance of Secondary Winding in Primary, measured in Electric Resistance can be negative.
Which unit is used to measure Resistance of Secondary Winding in Primary?
Resistance of Secondary Winding in Primary is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Resistance of Secondary Winding in Primary can be measured.
Copied!