Resistance at switch position n for multi range Ammeter Formula

Fx Copy
LaTeX Copy
Resistance at nth Switch Position is the nth number of resistances in multirange permanent magnet moving coil ammeter. Check FAQs
Rsn=R1+Rmmn
Rsn - Resistance at nth Switch Position?R1 - Resistance at Switch Position 1?Rm - Meter Resistance?mn - Nth Multiplying Factor?

Resistance at switch position n for multi range Ammeter Example

With values
With units
Only example

Here is how the Resistance at switch position n for multi range Ammeter equation looks like with Values.

Here is how the Resistance at switch position n for multi range Ammeter equation looks like with Units.

Here is how the Resistance at switch position n for multi range Ammeter equation looks like.

7.8947Edit=120Edit+30Edit19Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Measuring Instrument Circuits » fx Resistance at switch position n for multi range Ammeter

Resistance at switch position n for multi range Ammeter Solution

Follow our step by step solution on how to calculate Resistance at switch position n for multi range Ammeter?

FIRST Step Consider the formula
Rsn=R1+Rmmn
Next Step Substitute values of Variables
Rsn=120Ω+30Ω19
Next Step Prepare to Evaluate
Rsn=120+3019
Next Step Evaluate
Rsn=7.89473684210526Ω
LAST Step Rounding Answer
Rsn=7.8947Ω

Resistance at switch position n for multi range Ammeter Formula Elements

Variables
Resistance at nth Switch Position
Resistance at nth Switch Position is the nth number of resistances in multirange permanent magnet moving coil ammeter.
Symbol: Rsn
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Resistance at Switch Position 1
Resistance at Switch Position 1 is the value of the first shunt resistance in the multi range ammeter setup.
Symbol: R1
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Meter Resistance
Meter Resistance refers to the inherent electrical resistance present within a measuring instrument. It is the resistance that the instrument itself presents to the flow of electric current.
Symbol: Rm
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Nth Multiplying Factor
Nth Multiplying Factor is the multiplying power of coil associated with the nth resistor in multi range ammeter.
Symbol: mn
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Ammeter category

​Go Rsh of PMMC based Ammeter
Rsh=ImRmI-Im
​Go m of PMMC based Ammeter
m=1+(RmRsh)
​Go Nth resistance in multi-range Ammeter
Rn=Rmmn-1
​Go m of Moving Iron Ammeter
m=(RmRsh)1+(ωLRm)21+(ωLshRsh)2

How to Evaluate Resistance at switch position n for multi range Ammeter?

Resistance at switch position n for multi range Ammeter evaluator uses Resistance at nth Switch Position = (Resistance at Switch Position 1+Meter Resistance)/Nth Multiplying Factor to evaluate the Resistance at nth Switch Position, The Resistance at switch position n for multi range Ammeter formula is defined as the specific shunt resistor value that is used when the ammeter is set to its n-th range. This shunt resistor is critical in determining the amount of current that bypasses the sensitive meter movement, allowing the ammeter to measure higher currents without damaging the meter. Resistance at nth Switch Position is denoted by Rsn symbol.

How to evaluate Resistance at switch position n for multi range Ammeter using this online evaluator? To use this online evaluator for Resistance at switch position n for multi range Ammeter, enter Resistance at Switch Position 1 (R1), Meter Resistance (Rm) & Nth Multiplying Factor (mn) and hit the calculate button.

FAQs on Resistance at switch position n for multi range Ammeter

What is the formula to find Resistance at switch position n for multi range Ammeter?
The formula of Resistance at switch position n for multi range Ammeter is expressed as Resistance at nth Switch Position = (Resistance at Switch Position 1+Meter Resistance)/Nth Multiplying Factor. Here is an example- 7.894737 = (120+30)/19.
How to calculate Resistance at switch position n for multi range Ammeter?
With Resistance at Switch Position 1 (R1), Meter Resistance (Rm) & Nth Multiplying Factor (mn) we can find Resistance at switch position n for multi range Ammeter using the formula - Resistance at nth Switch Position = (Resistance at Switch Position 1+Meter Resistance)/Nth Multiplying Factor.
Can the Resistance at switch position n for multi range Ammeter be negative?
No, the Resistance at switch position n for multi range Ammeter, measured in Electric Resistance cannot be negative.
Which unit is used to measure Resistance at switch position n for multi range Ammeter?
Resistance at switch position n for multi range Ammeter is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Resistance at switch position n for multi range Ammeter can be measured.
Copied!