Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it. Check FAQs
R=ρLA
R - Resistance Underground AC?ρ - Resistivity?L - Length of Underground AC Wire?A - Area of Underground AC Wire?

Resistance (1-Phase 2-Wire US) Example

With values
With units
Only example

Here is how the Resistance (1-Phase 2-Wire US) equation looks like with Values.

Here is how the Resistance (1-Phase 2-Wire US) equation looks like with Units.

Here is how the Resistance (1-Phase 2-Wire US) equation looks like.

0.0003Edit=1.7E-5Edit24Edit1.28Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Resistance (1-Phase 2-Wire US)

Resistance (1-Phase 2-Wire US) Solution

Follow our step by step solution on how to calculate Resistance (1-Phase 2-Wire US)?

FIRST Step Consider the formula
R=ρLA
Next Step Substitute values of Variables
R=1.7E-5Ω*m24m1.28
Next Step Prepare to Evaluate
R=1.7E-5241.28
Next Step Evaluate
R=0.00031875Ω
LAST Step Rounding Answer
R=0.0003Ω

Resistance (1-Phase 2-Wire US) Formula Elements

Variables
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.

Other Formulas to find Resistance Underground AC

​Go Resistance using Volume of Conductor Material (1-Phase 2-Wire US)
R=Vρ2(A2)
​Go Resistance using Line Losses (1-Phase 2-Wire US)
R=Ploss2(I)2
​Go Resistance using Constant (1-Phase 2-Wire US)
R=KPlossVm2AL4(P)2

Other formulas in Resistance and Resistivity category

​Go Resistivity using Area of X-Section (1-Phase 2-Wire US)
ρ=A(Vm2)Ploss(cos(Φ))2(4)L(P2)
​Go Resistivity using Volume of Conductor Material (1-Phase 2-Wire US)
ρ=VPloss(Vm(cos(Φ)))28(PL)2
​Go Resistivity using Load Current (1-Phase 2-Wire US)
ρ=PlossA2(I)2L
​Go Resistivity using Line Losses (1-Phase 2-Wire US)
ρ=PlossA(Vmcos(Φ))24(P)2L

How to Evaluate Resistance (1-Phase 2-Wire US)?

Resistance (1-Phase 2-Wire US) evaluator uses Resistance Underground AC = Resistivity*Length of Underground AC Wire/Area of Underground AC Wire to evaluate the Resistance Underground AC, The Resistance (1-Phase 2-Wire US) formula is defined as a measure of the opposition to current flow in an electrical circuit. Resistance Underground AC is denoted by R symbol.

How to evaluate Resistance (1-Phase 2-Wire US) using this online evaluator? To use this online evaluator for Resistance (1-Phase 2-Wire US), enter Resistivity (ρ), Length of Underground AC Wire (L) & Area of Underground AC Wire (A) and hit the calculate button.

FAQs on Resistance (1-Phase 2-Wire US)

What is the formula to find Resistance (1-Phase 2-Wire US)?
The formula of Resistance (1-Phase 2-Wire US) is expressed as Resistance Underground AC = Resistivity*Length of Underground AC Wire/Area of Underground AC Wire. Here is an example- 0.000319 = 1.7E-05*24/1.28.
How to calculate Resistance (1-Phase 2-Wire US)?
With Resistivity (ρ), Length of Underground AC Wire (L) & Area of Underground AC Wire (A) we can find Resistance (1-Phase 2-Wire US) using the formula - Resistance Underground AC = Resistivity*Length of Underground AC Wire/Area of Underground AC Wire.
What are the other ways to Calculate Resistance Underground AC?
Here are the different ways to Calculate Resistance Underground AC-
  • Resistance Underground AC=Volume Of Conductor*Resistivity/(2*(Area of Underground AC Wire^2))OpenImg
  • Resistance Underground AC=Line Losses/(2*(Current Underground AC)^2)OpenImg
  • Resistance Underground AC=Constant Underground AC*Line Losses*(Maximum Voltage Underground AC^2)/(Area of Underground AC Wire*Length of Underground AC Wire*4*(Power Transmitted)^2)OpenImg
Can the Resistance (1-Phase 2-Wire US) be negative?
Yes, the Resistance (1-Phase 2-Wire US), measured in Electric Resistance can be negative.
Which unit is used to measure Resistance (1-Phase 2-Wire US)?
Resistance (1-Phase 2-Wire US) is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Resistance (1-Phase 2-Wire US) can be measured.
Copied!