Reserve Fire Pumping Capacity given Reserve Storage Formula

Fx Copy
LaTeX Copy
Capacity of Pump refers to the volume of fluid (such as water, sewage, or other liquids) that the pump is capable of moving within a given amount of time. Check FAQs
P=F-(VRt)
P - Capacity of Pump?F - Fire Demand?VR - Reserve Storage?t - Duration of Fire?

Reserve Fire Pumping Capacity given Reserve Storage Example

With values
With units
Only example

Here is how the Reserve Fire Pumping Capacity given Reserve Storage equation looks like with Values.

Here is how the Reserve Fire Pumping Capacity given Reserve Storage equation looks like with Units.

Here is how the Reserve Fire Pumping Capacity given Reserve Storage equation looks like.

120Edit=1100Edit-(1960Edit2Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Reserve Fire Pumping Capacity given Reserve Storage

Reserve Fire Pumping Capacity given Reserve Storage Solution

Follow our step by step solution on how to calculate Reserve Fire Pumping Capacity given Reserve Storage?

FIRST Step Consider the formula
P=F-(VRt)
Next Step Substitute values of Variables
P=1100L/d-(1960L2d)
Next Step Convert Units
P=1.3E-5m³/s-(1.96172800s)
Next Step Prepare to Evaluate
P=1.3E-5-(1.96172800)
Next Step Evaluate
P=1.38888888888891E-06m³/s
Next Step Convert to Output's Unit
P=120.000000000002L/d
LAST Step Rounding Answer
P=120L/d

Reserve Fire Pumping Capacity given Reserve Storage Formula Elements

Variables
Capacity of Pump
Capacity of Pump refers to the volume of fluid (such as water, sewage, or other liquids) that the pump is capable of moving within a given amount of time.
Symbol: P
Measurement: Volumetric Flow RateUnit: L/d
Note: Value should be greater than 0.
Fire Demand
Fire Demand is the amount of water required to extinguish fire.
Symbol: F
Measurement: Volumetric Flow RateUnit: L/d
Note: Value should be greater than 0.
Reserve Storage
Reserve Storage refers to the capacity within a system, such as a reservoir or a water treatment facility, that is intentionally left unused or untapped under normal operating conditions.
Symbol: VR
Measurement: VolumeUnit: L
Note: Value should be greater than 0.
Duration of Fire
Duration of Fire refers to the length of time that a fire burns within a given area or ecosystem.
Symbol: t
Measurement: TimeUnit: d
Note: Value can be positive or negative.

Other formulas in Capacity of Distribution Reservoir category

​Go Reserve Storage
VR=(F-P)t
​Go Fire Demand given Reserve Storage
F=(VRt)+P
​Go Fire Duration given Reserve Storage
t=VRF-P
​Go Total Storage Capacity of Reservoir
T=(a+b+(1024))D+(1024)(F-P)

How to Evaluate Reserve Fire Pumping Capacity given Reserve Storage?

Reserve Fire Pumping Capacity given Reserve Storage evaluator uses Capacity of Pump = Fire Demand-(Reserve Storage/Duration of Fire) to evaluate the Capacity of Pump, The Reserve Fire Pumping Capacity given Reserve Storage is defined as the surplus capacity available in case of emergencies or unexpected demands, such as firefighting situations, when we have prior information reserve storage. Capacity of Pump is denoted by P symbol.

How to evaluate Reserve Fire Pumping Capacity given Reserve Storage using this online evaluator? To use this online evaluator for Reserve Fire Pumping Capacity given Reserve Storage, enter Fire Demand (F), Reserve Storage (VR) & Duration of Fire (t) and hit the calculate button.

FAQs on Reserve Fire Pumping Capacity given Reserve Storage

What is the formula to find Reserve Fire Pumping Capacity given Reserve Storage?
The formula of Reserve Fire Pumping Capacity given Reserve Storage is expressed as Capacity of Pump = Fire Demand-(Reserve Storage/Duration of Fire). Here is an example- 1E+10 = 1.27314814814815E-05-(1.96/172800).
How to calculate Reserve Fire Pumping Capacity given Reserve Storage?
With Fire Demand (F), Reserve Storage (VR) & Duration of Fire (t) we can find Reserve Fire Pumping Capacity given Reserve Storage using the formula - Capacity of Pump = Fire Demand-(Reserve Storage/Duration of Fire).
Can the Reserve Fire Pumping Capacity given Reserve Storage be negative?
No, the Reserve Fire Pumping Capacity given Reserve Storage, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Reserve Fire Pumping Capacity given Reserve Storage?
Reserve Fire Pumping Capacity given Reserve Storage is usually measured using the Liter per day[L/d] for Volumetric Flow Rate. Cubic Meter per Second[L/d], Cubic Meter per Day[L/d], Cubic Meter per Hour[L/d] are the few other units in which Reserve Fire Pumping Capacity given Reserve Storage can be measured.
Copied!