Concentrated Load of Reaction is the reaction force that is assumed to act at a single point on the structure. Check FAQs
R=(6800tw3h)(1+(0.4rwf3))
R - Concentrated Load of Reaction?tw - Web Thickness?h - Clear Distance between Flanges?rwf - Slenderness of Web and Flange?

Required Stiffeners if Concentrated Load exceeds Load of Reaction R Example

With values
With units
Only example

Here is how the Required Stiffeners if Concentrated Load exceeds Load of Reaction R equation looks like with Values.

Here is how the Required Stiffeners if Concentrated Load exceeds Load of Reaction R equation looks like with Units.

Here is how the Required Stiffeners if Concentrated Load exceeds Load of Reaction R equation looks like.

234.0984Edit=(6800100Edit3122Edit)(1+(0.42Edit3))
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Design of Steel Structures » fx Required Stiffeners if Concentrated Load exceeds Load of Reaction R

Required Stiffeners if Concentrated Load exceeds Load of Reaction R Solution

Follow our step by step solution on how to calculate Required Stiffeners if Concentrated Load exceeds Load of Reaction R?

FIRST Step Consider the formula
R=(6800tw3h)(1+(0.4rwf3))
Next Step Substitute values of Variables
R=(6800100mm3122mm)(1+(0.423))
Next Step Convert Units
R=(68000.1m30.122m)(1+(0.423))
Next Step Prepare to Evaluate
R=(68000.130.122)(1+(0.423))
Next Step Evaluate
R=234098.360655738N
Next Step Convert to Output's Unit
R=234.098360655738kN
LAST Step Rounding Answer
R=234.0984kN

Required Stiffeners if Concentrated Load exceeds Load of Reaction R Formula Elements

Variables
Concentrated Load of Reaction
Concentrated Load of Reaction is the reaction force that is assumed to act at a single point on the structure.
Symbol: R
Measurement: ForceUnit: kN
Note: Value should be greater than 0.
Web Thickness
Web Thickness is the thickness of the web section in the member of I section.
Symbol: tw
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Clear Distance between Flanges
Clear Distance between Flanges refers to the distance between the two endpoints of the flange. That is the height of the web including fillets.
Symbol: h
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Slenderness of Web and Flange
Slenderness of Web and Flange of a structural element is a measure of its susceptibility to buckling under compressive stress.
Symbol: rwf
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Concentrated Load of Reaction

​Go Reaction of Concentrated Load given Allowable Compressive Stress
R=fatw(N+5k)
​Go Reaction of Concentrated Load applied at least Half of Depth of Beam
R=67.5tw2(1+3(ND)(twtf)1.5)Fytwtf
​Go Reaction of Concentrated Load when Applied at distance at least Half of Beam Depth
R=34tw2(1+3(ND)(twtf)1.5)Fytwtf

Other formulas in Webs under Concentrated Loads category

​Go Stress when Concentrated Load is Applied Close to Beam End
fa=Rtw(N+2.5k)
​Go Stress for Concentrated Load Applied at Distance Larger than Depth of Beam
fa=Rtw(N+5k)
​Go Length of Bearing when Load applied at Distance Larger than Depth of Beam
N=(Rfatw)-5k
​Go Web Thickness for Given Stress
tw=Rfa(N+5k)

How to Evaluate Required Stiffeners if Concentrated Load exceeds Load of Reaction R?

Required Stiffeners if Concentrated Load exceeds Load of Reaction R evaluator uses Concentrated Load of Reaction = ((6800*Web Thickness^3)/Clear Distance between Flanges)*(1+(0.4*Slenderness of Web and Flange^3)) to evaluate the Concentrated Load of Reaction, The Required Stiffeners if Concentrated Load exceeds Load of Reaction R formula is defined as the structural elements used to reinforce the parts of a structure under high-stress conditions. Concentrated Load of Reaction is denoted by R symbol.

How to evaluate Required Stiffeners if Concentrated Load exceeds Load of Reaction R using this online evaluator? To use this online evaluator for Required Stiffeners if Concentrated Load exceeds Load of Reaction R, enter Web Thickness (tw), Clear Distance between Flanges (h) & Slenderness of Web and Flange (rwf) and hit the calculate button.

FAQs on Required Stiffeners if Concentrated Load exceeds Load of Reaction R

What is the formula to find Required Stiffeners if Concentrated Load exceeds Load of Reaction R?
The formula of Required Stiffeners if Concentrated Load exceeds Load of Reaction R is expressed as Concentrated Load of Reaction = ((6800*Web Thickness^3)/Clear Distance between Flanges)*(1+(0.4*Slenderness of Web and Flange^3)). Here is an example- 0.000234 = ((6800*0.1^3)/0.122)*(1+(0.4*2^3)).
How to calculate Required Stiffeners if Concentrated Load exceeds Load of Reaction R?
With Web Thickness (tw), Clear Distance between Flanges (h) & Slenderness of Web and Flange (rwf) we can find Required Stiffeners if Concentrated Load exceeds Load of Reaction R using the formula - Concentrated Load of Reaction = ((6800*Web Thickness^3)/Clear Distance between Flanges)*(1+(0.4*Slenderness of Web and Flange^3)).
What are the other ways to Calculate Concentrated Load of Reaction?
Here are the different ways to Calculate Concentrated Load of Reaction-
  • Concentrated Load of Reaction=Compressive Stress*Web Thickness*(Bearing or Plate Length+5*Distance from Flange to Web Fillet)OpenImg
  • Concentrated Load of Reaction=67.5*Web Thickness^2*(1+3*(Bearing or Plate Length/Depth of Section)*(Web Thickness/Flange Thickness)^1.5)*sqrt(Yield Stress of Steel/(Web Thickness/Flange Thickness))OpenImg
  • Concentrated Load of Reaction=34*Web Thickness^2*(1+3*(Bearing or Plate Length/Depth of Section)*(Web Thickness/Flange Thickness)^1.5)*sqrt(Yield Stress of Steel/(Web Thickness/Flange Thickness))OpenImg
Can the Required Stiffeners if Concentrated Load exceeds Load of Reaction R be negative?
No, the Required Stiffeners if Concentrated Load exceeds Load of Reaction R, measured in Force cannot be negative.
Which unit is used to measure Required Stiffeners if Concentrated Load exceeds Load of Reaction R?
Required Stiffeners if Concentrated Load exceeds Load of Reaction R is usually measured using the Kilonewton[kN] for Force. Newton[kN], Exanewton[kN], Meganewton[kN] are the few other units in which Required Stiffeners if Concentrated Load exceeds Load of Reaction R can be measured.
Copied!