Reoxygenation Coefficient at 20 Degree Celsius Formula

Fx Copy
LaTeX Copy
Reoxygenation Coefficient at Temperature 20 is the BOD rate constant at 20°C temperature. Check FAQs
KR(20)=KR(1.016)T-20
KR(20) - Reoxygenation Coefficient at Temperature 20?KR - Reoxygenation Coefficient?T - Temperature?

Reoxygenation Coefficient at 20 Degree Celsius Example

With values
With units
Only example

Here is how the Reoxygenation Coefficient at 20 Degree Celsius equation looks like with Values.

Here is how the Reoxygenation Coefficient at 20 Degree Celsius equation looks like with Units.

Here is how the Reoxygenation Coefficient at 20 Degree Celsius equation looks like.

0.22Edit=0.22Edit(1.016)20Edit-20
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Reoxygenation Coefficient at 20 Degree Celsius

Reoxygenation Coefficient at 20 Degree Celsius Solution

Follow our step by step solution on how to calculate Reoxygenation Coefficient at 20 Degree Celsius?

FIRST Step Consider the formula
KR(20)=KR(1.016)T-20
Next Step Substitute values of Variables
KR(20)=0.22d⁻¹(1.016)20K-20
Next Step Convert Units
KR(20)=2.5E-6s⁻¹(1.016)20K-20
Next Step Prepare to Evaluate
KR(20)=2.5E-6(1.016)20-20
Next Step Evaluate
KR(20)=2.5462962962963E-06s⁻¹
LAST Step Convert to Output's Unit
KR(20)=0.22d⁻¹

Reoxygenation Coefficient at 20 Degree Celsius Formula Elements

Variables
Reoxygenation Coefficient at Temperature 20
Reoxygenation Coefficient at Temperature 20 is the BOD rate constant at 20°C temperature.
Symbol: KR(20)
Measurement: First Order Reaction Rate ConstantUnit: d⁻¹
Note: Value should be greater than 0.
Reoxygenation Coefficient
Reoxygenation Coefficient is referred as the parameter used in water quality modeling to describe the rate at which oxygen is transferred from the atmosphere to the water body.
Symbol: KR
Measurement: First Order Reaction Rate ConstantUnit: d⁻¹
Note: Value should be greater than 0.
Temperature
Temperature is the degree or intensity of heat present in a substance or object.
Symbol: T
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.

Other formulas in Reoxygenation Coefficient category

​Go Reoxygenation Coefficients
KR=KR(20)(1.016)T-20
​Go Reoxygenation Coefficient given Self Purification Constant
KR=KDf
​Go Reoxygenation Coefficient given Critical Oxygen Deficit
KR=KDLt10-KDtcDc
​Go Stream Depth given Reoxygenation Coefficient
d=(3.9vk)11.5

How to Evaluate Reoxygenation Coefficient at 20 Degree Celsius?

Reoxygenation Coefficient at 20 Degree Celsius evaluator uses Reoxygenation Coefficient at Temperature 20 = Reoxygenation Coefficient/((1.016)^(Temperature-20)) to evaluate the Reoxygenation Coefficient at Temperature 20, The Reoxygenation Coefficient at 20 degree Celsius formula is defined as the rate at which oxygen from the atmosphere dissolves into the water, replenishing the oxygen consumed by biological and chemical processes. The reoxygenation process is essential for maintaining healthy DO levels, which are vital for the survival of aquatic organisms. Reoxygenation Coefficient at Temperature 20 is denoted by KR(20) symbol.

How to evaluate Reoxygenation Coefficient at 20 Degree Celsius using this online evaluator? To use this online evaluator for Reoxygenation Coefficient at 20 Degree Celsius, enter Reoxygenation Coefficient (KR) & Temperature (T) and hit the calculate button.

FAQs on Reoxygenation Coefficient at 20 Degree Celsius

What is the formula to find Reoxygenation Coefficient at 20 Degree Celsius?
The formula of Reoxygenation Coefficient at 20 Degree Celsius is expressed as Reoxygenation Coefficient at Temperature 20 = Reoxygenation Coefficient/((1.016)^(Temperature-20)). Here is an example- 17280 = 2.5462962962963E-06/((1.016)^(20-20)).
How to calculate Reoxygenation Coefficient at 20 Degree Celsius?
With Reoxygenation Coefficient (KR) & Temperature (T) we can find Reoxygenation Coefficient at 20 Degree Celsius using the formula - Reoxygenation Coefficient at Temperature 20 = Reoxygenation Coefficient/((1.016)^(Temperature-20)).
Can the Reoxygenation Coefficient at 20 Degree Celsius be negative?
No, the Reoxygenation Coefficient at 20 Degree Celsius, measured in First Order Reaction Rate Constant cannot be negative.
Which unit is used to measure Reoxygenation Coefficient at 20 Degree Celsius?
Reoxygenation Coefficient at 20 Degree Celsius is usually measured using the 1 Per Day[d⁻¹] for First Order Reaction Rate Constant. 1 Per Second[d⁻¹], 1 Per Millisecond[d⁻¹], 1 Per Hour[d⁻¹] are the few other units in which Reoxygenation Coefficient at 20 Degree Celsius can be measured.
Copied!