Reduced Volume of a fluid is computed from the ideal gas law as the ratio of its actual volume to critical volume. Check FAQs
Vr=Vrealb'+([R]T'c4P'c)
Vr - Reduced Volume?Vreal - Volume of Real Gas?b' - Clausius Parameter b for Real Gas?T'c - Critical Temperature For Clausius Model?P'c - Critical Pressure of Real Gas?[R] - Universal gas constant?

Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters Example

With values
With units
Only example

Here is how the Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters equation looks like with Values.

Here is how the Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters equation looks like with Units.

Here is how the Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters equation looks like.

8800.8125Edit=22Edit0.0024Edit+(8.3145154.4Edit44.6E+6Edit)
You are here -
HomeIcon Home » Category Chemistry » Category Kinetic Theory of Gases » Category Real Gas » fx Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters

Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters Solution

Follow our step by step solution on how to calculate Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters?

FIRST Step Consider the formula
Vr=Vrealb'+([R]T'c4P'c)
Next Step Substitute values of Variables
Vr=22L0.0024+([R]154.4K44.6E+6Pa)
Next Step Substitute values of Constants
Vr=22L0.0024+(8.3145154.4K44.6E+6Pa)
Next Step Convert Units
Vr=0.0220.0024+(8.3145154.4K44.6E+6Pa)
Next Step Prepare to Evaluate
Vr=0.0220.0024+(8.3145154.444.6E+6)
Next Step Evaluate
Vr=8.8008125391803
Next Step Convert to Output's Unit
Vr=8800.8125391803L
LAST Step Rounding Answer
Vr=8800.8125L

Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters Formula Elements

Variables
Constants
Reduced Volume
Reduced Volume of a fluid is computed from the ideal gas law as the ratio of its actual volume to critical volume.
Symbol: Vr
Measurement: VolumeUnit: L
Note: Value can be positive or negative.
Volume of Real Gas
Volume of Real Gas is the space occupied by that real gas at standard temperature and pressure.
Symbol: Vreal
Measurement: VolumeUnit: L
Note: Value should be greater than 0.
Clausius Parameter b for Real Gas
Clausius Parameter b for Real Gas is an empirical parameter characteristic to equation obtained from Clausius model of real gas.
Symbol: b'
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Critical Temperature For Clausius Model
Critical Temperature For Clausius Model is the highest temperature at which the substance can exist as a liquid. At this phase boundaries vanish, the substance can exist both as a liquid and vapor.
Symbol: T'c
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Critical Pressure of Real Gas
Critical Pressure of Real Gas is the minimum pressure required to liquify a substance at the critical temperature.
Symbol: P'c
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Universal gas constant
Universal gas constant is a fundamental physical constant that appears in the ideal gas law, relating the pressure, volume, and temperature of an ideal gas.
Symbol: [R]
Value: 8.31446261815324

Other Formulas to find Reduced Volume

​Go Reduced Volume of Real Gas given Clausius Parameter b, Reduced and Actual Parameters
Vr=Vrealb'+([R](TrgTr)4(pPr))
​Go Reduced Volume of Real Gas given Clausius Parameter c and Actual Parameters
Vr=Vreal(3[R]Tc8P'c)-c
​Go Reduced Volume of Real Gas using Actual and Critical Volume
Vr=VrealVc

Other formulas in Reduced Volume category

​Go Reduced Volume of Real Gas given Clausius Parameter c, Reduced and Actual Parameters
Vr_RP_AP=Vreal(3[R](TrealTr)8(PrealPr))-c
​Go Reduced Molar Volume of Real Gas using Clausius Equation given Critical and Actual Parameters
V'm,r=([R]Trgp+(aTrg))+b'Vm,c
​Go Reduced Molar Volume of Real Gas using Clausius Equation given Reduced and Actual Parameters
V'm,r=([R]Trgp+(aTrg))+b'Vm
​Go Reduced Molar Volume of Real Gas using Clausius Equation given Reduced and Critical Parameters
V'm,r=([R](TrT'c)(PrP'c)+(aTrT'c))+b'Vm,c

How to Evaluate Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters?

Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters evaluator uses Reduced Volume = Volume of Real Gas/(Clausius Parameter b for Real Gas+(([R]*Critical Temperature For Clausius Model)/(4*Critical Pressure of Real Gas))) to evaluate the Reduced Volume, The Reduced Volume of real gas given Clausius parameter b and actual parameters formula is defined as the ratio of its actual volume to critical volume. Reduced Volume is denoted by Vr symbol.

How to evaluate Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters using this online evaluator? To use this online evaluator for Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters, enter Volume of Real Gas (Vreal), Clausius Parameter b for Real Gas (b'), Critical Temperature For Clausius Model (T'c) & Critical Pressure of Real Gas (P'c) and hit the calculate button.

FAQs on Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters

What is the formula to find Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters?
The formula of Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters is expressed as Reduced Volume = Volume of Real Gas/(Clausius Parameter b for Real Gas+(([R]*Critical Temperature For Clausius Model)/(4*Critical Pressure of Real Gas))). Here is an example- 8.1E+6 = 0.022/(0.00243+(([R]*154.4)/(4*4600000))).
How to calculate Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters?
With Volume of Real Gas (Vreal), Clausius Parameter b for Real Gas (b'), Critical Temperature For Clausius Model (T'c) & Critical Pressure of Real Gas (P'c) we can find Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters using the formula - Reduced Volume = Volume of Real Gas/(Clausius Parameter b for Real Gas+(([R]*Critical Temperature For Clausius Model)/(4*Critical Pressure of Real Gas))). This formula also uses Universal gas constant .
What are the other ways to Calculate Reduced Volume?
Here are the different ways to Calculate Reduced Volume-
  • Reduced Volume=Volume of Real Gas/(Clausius Parameter b for Real Gas+(([R]*(Temperature of Real Gas/Reduced Temperature))/(4*(Pressure/Reduced Pressure))))OpenImg
  • Reduced Volume=Volume of Real Gas/(((3*[R]*Critical Temperature)/(8*Critical Pressure of Real Gas))-Clausius Parameter c)OpenImg
  • Reduced Volume=Volume of Real Gas/Critical VolumeOpenImg
Can the Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters be negative?
Yes, the Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters, measured in Volume can be negative.
Which unit is used to measure Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters?
Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters is usually measured using the Liter[L] for Volume. Cubic Meter[L], Cubic Centimeter[L], Cubic Millimeter[L] are the few other units in which Reduced Volume of Real Gas given Clausius Parameter b and Actual Parameters can be measured.
Copied!