Reduced Plasma Frequency Formula

Fx Copy
LaTeX Copy
Reduced Plasma Frequency is defined as the reduction in plasma frequency in the ionic level due to several reasons. Check FAQs
ωq=fpR
ωq - Reduced Plasma Frequency?fp - Plasma Frequency?R - Space Charge Reduction Factor?

Reduced Plasma Frequency Example

With values
With units
Only example

Here is how the Reduced Plasma Frequency equation looks like with Values.

Here is how the Reduced Plasma Frequency equation looks like with Units.

Here is how the Reduced Plasma Frequency equation looks like.

1.2E+6Edit=1.4E+6Edit0.87Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Microwave Theory » fx Reduced Plasma Frequency

Reduced Plasma Frequency Solution

Follow our step by step solution on how to calculate Reduced Plasma Frequency?

FIRST Step Consider the formula
ωq=fpR
Next Step Substitute values of Variables
ωq=1.4E+6rad/s0.87
Next Step Prepare to Evaluate
ωq=1.4E+60.87
Next Step Evaluate
ωq=1218000rad/s
LAST Step Rounding Answer
ωq=1.2E+6rad/s

Reduced Plasma Frequency Formula Elements

Variables
Reduced Plasma Frequency
Reduced Plasma Frequency is defined as the reduction in plasma frequency in the ionic level due to several reasons.
Symbol: ωq
Measurement: Angular FrequencyUnit: rad/s
Note: Value should be greater than 0.
Plasma Frequency
Plasma frequency is the frequency at which the response of a plasma is dominated by the motion of free electrons, rather than by the slower motion of ions or other species in the plasma.
Symbol: fp
Measurement: Angular FrequencyUnit: rad/s
Note: Value should be greater than 0.
Space Charge Reduction Factor
Space charge reduction factor is a factor that accounts for the reduction of electron transit time due to the presence of a space charge in a vacuum tube.
Symbol: R
Measurement: NAUnit: Unitless
Note: Value should be between -0.9999 to 1.0001.

Other formulas in Beam Tube category

​Go Skin Depth
δ=ρπμrf
​Go Power Generated in Anode Circuit
Pgen=Pdcηe
​Go Rectangular Microwave Pulse Peak Power
Ppk=PavgD
​Go Carrier Frequency in Spectral Line
fc=fsl-Nsfr

How to Evaluate Reduced Plasma Frequency?

Reduced Plasma Frequency evaluator uses Reduced Plasma Frequency = Plasma Frequency*Space Charge Reduction Factor to evaluate the Reduced Plasma Frequency, The Reduced Plasma Frequency formula is defined as the cutoff frequency of plasma waves, which is the frequency at which the wave propagation is inhibited due to the presence of the magnetic field. Reduced Plasma Frequency is denoted by ωq symbol.

How to evaluate Reduced Plasma Frequency using this online evaluator? To use this online evaluator for Reduced Plasma Frequency, enter Plasma Frequency (fp) & Space Charge Reduction Factor (R) and hit the calculate button.

FAQs on Reduced Plasma Frequency

What is the formula to find Reduced Plasma Frequency?
The formula of Reduced Plasma Frequency is expressed as Reduced Plasma Frequency = Plasma Frequency*Space Charge Reduction Factor. Here is an example- 1.2E+6 = 1400000*0.87.
How to calculate Reduced Plasma Frequency?
With Plasma Frequency (fp) & Space Charge Reduction Factor (R) we can find Reduced Plasma Frequency using the formula - Reduced Plasma Frequency = Plasma Frequency*Space Charge Reduction Factor.
Can the Reduced Plasma Frequency be negative?
No, the Reduced Plasma Frequency, measured in Angular Frequency cannot be negative.
Which unit is used to measure Reduced Plasma Frequency?
Reduced Plasma Frequency is usually measured using the Radian per Second[rad/s] for Angular Frequency. Degree per Second[rad/s] are the few other units in which Reduced Plasma Frequency can be measured.
Copied!