Fx Copy
LaTeX Copy
The Recovery Factor is a measure of the efficiency of fluid recovery in viscous flow scenarios, indicating how much of the fluid's energy is successfully harnessed. Check FAQs
r=Twall-TstaticTt-Tstatic
r - Recovery Factor?Twall - Adiabatic Wall Temperature?Tstatic - Static Temperature?Tt - Total Temperature?

Recovery Factor using Temperature Example

With values
With units
Only example

Here is how the Recovery Factor using Temperature equation looks like with Values.

Here is how the Recovery Factor using Temperature equation looks like with Units.

Here is how the Recovery Factor using Temperature equation looks like.

2.7Edit=425Edit-350Edit377.7777Edit-350Edit
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Fluid Mechanics » fx Recovery Factor using Temperature

Recovery Factor using Temperature Solution

Follow our step by step solution on how to calculate Recovery Factor using Temperature?

FIRST Step Consider the formula
r=Twall-TstaticTt-Tstatic
Next Step Substitute values of Variables
r=425K-350K377.7777K-350K
Next Step Prepare to Evaluate
r=425-350377.7777-350
Next Step Evaluate
r=2.70000756002117
LAST Step Rounding Answer
r=2.7

Recovery Factor using Temperature Formula Elements

Variables
Recovery Factor
The Recovery Factor is a measure of the efficiency of fluid recovery in viscous flow scenarios, indicating how much of the fluid's energy is successfully harnessed.
Symbol: r
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Adiabatic Wall Temperature
The Adiabatic Wall Temperature is the temperature of a wall in a fluid flow scenario, assuming no heat transfer occurs between the wall and the fluid.
Symbol: Twall
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Static Temperature
The Static Temperature is the temperature of a fluid at rest, providing essential information about its thermal state in viscous flow scenarios.
Symbol: Tstatic
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Total Temperature
The Total Temperature is the temperature of a fluid that accounts for both its thermal energy and the kinetic energy due to its motion.
Symbol: Tt
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.

Other Formulas to find Recovery Factor

​Go Recovery Factor Calculation using Prandtl Number
r=Pr
​Go Recovery Factor for Flat Plate with Viscous Flow
r=haw-heh0-he

Other formulas in Viscous Flow category

​Go Adiabatic Wall Enthalpy for Flat Plate
haw=he+r(h0-he)
​Go Adiabatic Wall Enthalpy using Recovery Factor
haw=he+rue22
​Go Aerodynamic Heating Equation for Stanton number
St=qwρeue(haw-hw)
​Go Coefficient of Friction using Stanton Number for Flat Plate Case
μfriction=2StPr-23

How to Evaluate Recovery Factor using Temperature?

Recovery Factor using Temperature evaluator uses Recovery Factor = (Adiabatic Wall Temperature-Static Temperature)/(Total Temperature-Static Temperature) to evaluate the Recovery Factor, Recovery Factor using Temperature formula is defined as a dimensionless quantity that characterizes the heat transfer between a flat plate and a fluid in viscous flow, providing a measure of the temperature difference between the wall and the static fluid. Recovery Factor is denoted by r symbol.

How to evaluate Recovery Factor using Temperature using this online evaluator? To use this online evaluator for Recovery Factor using Temperature, enter Adiabatic Wall Temperature (Twall), Static Temperature (Tstatic) & Total Temperature (Tt) and hit the calculate button.

FAQs on Recovery Factor using Temperature

What is the formula to find Recovery Factor using Temperature?
The formula of Recovery Factor using Temperature is expressed as Recovery Factor = (Adiabatic Wall Temperature-Static Temperature)/(Total Temperature-Static Temperature). Here is an example- 3 = (425-350)/(377.7777-350).
How to calculate Recovery Factor using Temperature?
With Adiabatic Wall Temperature (Twall), Static Temperature (Tstatic) & Total Temperature (Tt) we can find Recovery Factor using Temperature using the formula - Recovery Factor = (Adiabatic Wall Temperature-Static Temperature)/(Total Temperature-Static Temperature).
What are the other ways to Calculate Recovery Factor?
Here are the different ways to Calculate Recovery Factor-
  • Recovery Factor=sqrt(Prandtl Number)OpenImg
  • Recovery Factor=(Adiabatic Wall Enthalpy-Static Enthalpy)/(Total Specific Enthalpy-Static Enthalpy)OpenImg
Copied!