Fx Copy
LaTeX Copy
The Recharge of Ground Water Body from the stream refers to the hydrologic process, where water moves downward from surface water to groundwater. Check FAQs
Is=R-RG+B-I
Is - Recharge of Ground Water Body?R - Possible Recharge?RG - Gross Recharge due to Rainfall?B - Base Flow into the Stream from the Area?I - Net Ground Water Flowing Outside Catchment?

Recharge from Stream into Ground water Body given Possible Recharge Example

With values
With units
Only example

Here is how the Recharge from Stream into Ground water Body given Possible Recharge equation looks like with Values.

Here is how the Recharge from Stream into Ground water Body given Possible Recharge equation looks like with Units.

Here is how the Recharge from Stream into Ground water Body given Possible Recharge equation looks like.

19Edit=70Edit-45Edit+6Edit-12Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Recharge from Stream into Ground water Body given Possible Recharge

Recharge from Stream into Ground water Body given Possible Recharge Solution

Follow our step by step solution on how to calculate Recharge from Stream into Ground water Body given Possible Recharge?

FIRST Step Consider the formula
Is=R-RG+B-I
Next Step Substitute values of Variables
Is=70m³/s-45m³/s+6m³/s-12m³/s
Next Step Prepare to Evaluate
Is=70-45+6-12
LAST Step Evaluate
Is=19m³/s

Recharge from Stream into Ground water Body given Possible Recharge Formula Elements

Variables
Recharge of Ground Water Body
The Recharge of Ground Water Body from the stream refers to the hydrologic process, where water moves downward from surface water to groundwater.
Symbol: Is
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Possible Recharge
The Possible Recharge refers to the gross recharge minus the natural recharge of the area.
Symbol: R
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Gross Recharge due to Rainfall
The Gross Recharge due to Rainfall refers to the total amount of water that infiltrates the ground as a result of precipitation.
Symbol: RG
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Base Flow into the Stream from the Area
The Base Flow into the Stream from the Area refers to the flow that is not runoff, it is water from the ground, flowing into the channel over a long time and with a certain delay.
Symbol: B
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Net Ground Water Flowing Outside Catchment
The Net Ground Water Flowing Outside Catchment refers to the steady-state groundwater flow through aquifers.
Symbol: I
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other Formulas to find Recharge of Ground Water Body

​Go Equation for Recharge from Stream into Ground Water Body
Is=(hASY)-RG+DG+B-I

Other formulas in Groundwater Level Fluctuation category

​Go Equation for Specific Yield
SY=RG-DG-B+Is+IAh
​Go Equation for Gross Recharge due to Rainfall and other Sources
RG=(hSYA)+DG+B-Is-I
​Go Equation for Gross Water Draft
DG=RG-B+Is+I-(hSYA)
​Go Equation for Base Flow into Stream from Area
B=RG-DG+Is+I-(hSYA)

How to Evaluate Recharge from Stream into Ground water Body given Possible Recharge?

Recharge from Stream into Ground water Body given Possible Recharge evaluator uses Recharge of Ground Water Body = Possible Recharge-Gross Recharge due to Rainfall+Base Flow into the Stream from the Area-Net Ground Water Flowing Outside Catchment to evaluate the Recharge of Ground Water Body, The Recharge from Stream into Ground water Body given Possible Recharge formula is defined as the hydrologic process, where water moves downward from stream to groundwater. Recharge of Ground Water Body is denoted by Is symbol.

How to evaluate Recharge from Stream into Ground water Body given Possible Recharge using this online evaluator? To use this online evaluator for Recharge from Stream into Ground water Body given Possible Recharge, enter Possible Recharge (R), Gross Recharge due to Rainfall (RG), Base Flow into the Stream from the Area (B) & Net Ground Water Flowing Outside Catchment (I) and hit the calculate button.

FAQs on Recharge from Stream into Ground water Body given Possible Recharge

What is the formula to find Recharge from Stream into Ground water Body given Possible Recharge?
The formula of Recharge from Stream into Ground water Body given Possible Recharge is expressed as Recharge of Ground Water Body = Possible Recharge-Gross Recharge due to Rainfall+Base Flow into the Stream from the Area-Net Ground Water Flowing Outside Catchment. Here is an example- 19 = 70-45+6-12.
How to calculate Recharge from Stream into Ground water Body given Possible Recharge?
With Possible Recharge (R), Gross Recharge due to Rainfall (RG), Base Flow into the Stream from the Area (B) & Net Ground Water Flowing Outside Catchment (I) we can find Recharge from Stream into Ground water Body given Possible Recharge using the formula - Recharge of Ground Water Body = Possible Recharge-Gross Recharge due to Rainfall+Base Flow into the Stream from the Area-Net Ground Water Flowing Outside Catchment.
What are the other ways to Calculate Recharge of Ground Water Body?
Here are the different ways to Calculate Recharge of Ground Water Body-
  • Recharge of Ground Water Body=(Water Level Fluctuation*Watershed Area*Specific Yield)-Gross Recharge due to Rainfall+Gross Water Draft+Base Flow into the Stream from the Area-Net Ground Water Flowing Outside CatchmentOpenImg
Can the Recharge from Stream into Ground water Body given Possible Recharge be negative?
No, the Recharge from Stream into Ground water Body given Possible Recharge, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Recharge from Stream into Ground water Body given Possible Recharge?
Recharge from Stream into Ground water Body given Possible Recharge is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Recharge from Stream into Ground water Body given Possible Recharge can be measured.
Copied!