Fx Copy
LaTeX Copy
The Recharge from Rainfall in Hard Rock Areas refers to process where rainwater infiltrates soil and percolates down to replenish groundwater reserves in regions characterized by hard rock formations. Check FAQs
Rhra=8AcrPnm
Rhra - Recharge from Rainfall in Hard Rock Areas?Acr - Area of Computation for Recharge?Pnm - Normal Rainfall in Monsoon Season?

Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt Example

With values
With units
Only example

Here is how the Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt equation looks like with Values.

Here is how the Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt equation looks like with Units.

Here is how the Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt equation looks like.

2.5536Edit=813.3Edit0.024Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt

Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt Solution

Follow our step by step solution on how to calculate Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt?

FIRST Step Consider the formula
Rhra=8AcrPnm
Next Step Substitute values of Variables
Rhra=813.30.024m
Next Step Prepare to Evaluate
Rhra=813.30.024
LAST Step Evaluate
Rhra=2.5536m³/s

Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt Formula Elements

Variables
Recharge from Rainfall in Hard Rock Areas
The Recharge from Rainfall in Hard Rock Areas refers to process where rainwater infiltrates soil and percolates down to replenish groundwater reserves in regions characterized by hard rock formations.
Symbol: Rhra
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Area of Computation for Recharge
The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources.
Symbol: Acr
Measurement: AreaUnit:
Note: Value can be positive or negative.
Normal Rainfall in Monsoon Season
The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region.
Symbol: Pnm
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other Formulas to find Recharge from Rainfall in Hard Rock Areas

​Go Recharge from Rainfall in Hard Rock Areas with Significant Clay Content
Rhra=8AcrPnm

Other formulas in Recommended Value for Rainfall Factor for Various Hydrogeologic Conditions based on Norms category

​Go Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas
Rai=22AcrPnm
​Go Recharge from Rainfall in East Coast Alluvial Areas
Raec=16AcrPnm
​Go Recharge from Rainfall in West Coast Areas based on Recommended Rainfall Infiltration Factor
Rawc=10AcrPnm
​Go Recharge from Rainfall in Hard Rock Areas with Low Clay Content
Rhrc=11AcrPnm

How to Evaluate Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt?

Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt evaluator uses Recharge from Rainfall in Hard Rock Areas = 8*Area of Computation for Recharge*Normal Rainfall in Monsoon Season to evaluate the Recharge from Rainfall in Hard Rock Areas, The Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt formula is defined as the process by which rainwater infiltrates into the ground in regions where the geological formations consist of basalt characterized by vesicles (small cavities) and joints (fractures). Recharge from Rainfall in Hard Rock Areas is denoted by Rhra symbol.

How to evaluate Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt using this online evaluator? To use this online evaluator for Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt, enter Area of Computation for Recharge (Acr) & Normal Rainfall in Monsoon Season (Pnm) and hit the calculate button.

FAQs on Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt

What is the formula to find Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt?
The formula of Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt is expressed as Recharge from Rainfall in Hard Rock Areas = 8*Area of Computation for Recharge*Normal Rainfall in Monsoon Season. Here is an example- 2.5536 = 8*13.3*0.024.
How to calculate Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt?
With Area of Computation for Recharge (Acr) & Normal Rainfall in Monsoon Season (Pnm) we can find Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt using the formula - Recharge from Rainfall in Hard Rock Areas = 8*Area of Computation for Recharge*Normal Rainfall in Monsoon Season.
What are the other ways to Calculate Recharge from Rainfall in Hard Rock Areas?
Here are the different ways to Calculate Recharge from Rainfall in Hard Rock Areas-
  • Recharge from Rainfall in Hard Rock Areas=8*Area of Computation for Recharge*Normal Rainfall in Monsoon SeasonOpenImg
Can the Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt be negative?
Yes, the Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt?
Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Recharge from Rainfall in Hard Rock Areas with Vesicular and Jointed Basalt can be measured.
Copied!