Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt Formula

Fx Copy
LaTeX Copy
Recharge from Rainfall in Hard Rock Vesicular is the process by which precipitation infiltrates into the ground through fractures, joints, and vesicles in hard rock formations. Check FAQs
Rhrv=5AcrPnm
Rhrv - Recharge from Rainfall in Hard Rock Vesicular?Acr - Area of Computation for Recharge?Pnm - Normal Rainfall in Monsoon Season?

Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt Example

With values
With units
Only example

Here is how the Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt equation looks like with Values.

Here is how the Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt equation looks like with Units.

Here is how the Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt equation looks like.

1.596Edit=513.3Edit0.024Edit
You are here -

Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt Solution

Follow our step by step solution on how to calculate Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt?

FIRST Step Consider the formula
Rhrv=5AcrPnm
Next Step Substitute values of Variables
Rhrv=513.30.024m
Next Step Prepare to Evaluate
Rhrv=513.30.024
LAST Step Evaluate
Rhrv=1.596m³/s

Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt Formula Elements

Variables
Recharge from Rainfall in Hard Rock Vesicular
Recharge from Rainfall in Hard Rock Vesicular is the process by which precipitation infiltrates into the ground through fractures, joints, and vesicles in hard rock formations.
Symbol: Rhrv
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Area of Computation for Recharge
The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources.
Symbol: Acr
Measurement: AreaUnit:
Note: Value can be positive or negative.
Normal Rainfall in Monsoon Season
The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region.
Symbol: Pnm
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other formulas in Minimum Value of Rainfall Factor for Various Hydrogeologic Conditions based on the Norms category

​Go Recharge from Rainfall in Indo Gangetic and Inland Alluvial Areas for Known Minimum Rainfall Factor
Rrf=20AcrPnm
​Go Recharge from Rainfall in Silty Alluvial Areas for Known Minimum Rainfall Factor
Rrf=20AcrPnm
​Go Recharge from Rainfall in West Coast Alluvial Areas for Known Minimum Rainfall Factor
Rawc=8AcrPnm
​Go Recharge from Rainfall in Hard Rock Areas with Low Clay content for Known Minimum Rainfall Factor
Rhra=10AcrPnm

How to Evaluate Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt?

Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt evaluator uses Recharge from Rainfall in Hard Rock Vesicular = 5*Area of Computation for Recharge*Normal Rainfall in Monsoon Season to evaluate the Recharge from Rainfall in Hard Rock Vesicular, The Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt formula is defined as a hydrologic process, where water moves downward from surface water to groundwater in hard rock areas. This recharge process is of significant importance in engineering hydrology, which deals with the study of water movement and management within natural and engineered systems. Recharge from Rainfall in Hard Rock Vesicular is denoted by Rhrv symbol.

How to evaluate Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt using this online evaluator? To use this online evaluator for Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt, enter Area of Computation for Recharge (Acr) & Normal Rainfall in Monsoon Season (Pnm) and hit the calculate button.

FAQs on Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt

What is the formula to find Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt?
The formula of Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt is expressed as Recharge from Rainfall in Hard Rock Vesicular = 5*Area of Computation for Recharge*Normal Rainfall in Monsoon Season. Here is an example- 1.596 = 5*13.3*0.024.
How to calculate Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt?
With Area of Computation for Recharge (Acr) & Normal Rainfall in Monsoon Season (Pnm) we can find Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt using the formula - Recharge from Rainfall in Hard Rock Vesicular = 5*Area of Computation for Recharge*Normal Rainfall in Monsoon Season.
Can the Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt be negative?
Yes, the Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt?
Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Recharge from Rainfall in Hard Rock Areas consisting Vesicular and Jointed Basalt can be measured.
Copied!