Real Power for Constant Load Current Formula

Fx Copy
LaTeX Copy
The Real Power Full Converter is the average power in watts delivered to a load in a full converter based circuit. It is the only useful power. It is the actual power dissipated by the load. Check FAQs
P(full)=VL(full)IL(full)cos(αfull)
P(full) - Real Power Full Converter?VL(full) - Load Voltage Full Converter?IL(full) - Load Current Full converter?αfull - Firing Angle Full Converter?

Real Power for Constant Load Current Example

With values
With units
Only example

Here is how the Real Power for Constant Load Current equation looks like with Values.

Here is how the Real Power for Constant Load Current equation looks like with Units.

Here is how the Real Power for Constant Load Current equation looks like.

40.548Edit=99Edit0.5Editcos(35Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Real Power for Constant Load Current

Real Power for Constant Load Current Solution

Follow our step by step solution on how to calculate Real Power for Constant Load Current?

FIRST Step Consider the formula
P(full)=VL(full)IL(full)cos(αfull)
Next Step Substitute values of Variables
P(full)=99V0.5Acos(35°)
Next Step Convert Units
P(full)=99V0.5Acos(0.6109rad)
Next Step Prepare to Evaluate
P(full)=990.5cos(0.6109)
Next Step Evaluate
P(full)=40.5480261923083W
LAST Step Rounding Answer
P(full)=40.548W

Real Power for Constant Load Current Formula Elements

Variables
Functions
Real Power Full Converter
The Real Power Full Converter is the average power in watts delivered to a load in a full converter based circuit. It is the only useful power. It is the actual power dissipated by the load.
Symbol: P(full)
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Load Voltage Full Converter
Load Voltage Full Converter is defined as the voltage developed at the load terminal of a full converter circuit.
Symbol: VL(full)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Load Current Full converter
Load Current Full converter is defined as the current flowing through the load terminal of a full converter circuit.
Symbol: IL(full)
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Firing Angle Full Converter
Firing Angle Full Converter refers to the point within each AC voltage cycle at which the thyristors are triggered to conduct current in a full converter.
Symbol: αfull
Measurement: AngleUnit: °
Note: Value should be less than 180.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other formulas in Single Phase Full Converter category

​Go Average DC Output Voltage of Single Phase Full Converter
Vavg-dc(full)=2Vm-dc(full)cos(αfull)π
​Go Maximum Output DC Voltage of Single Phase Full Converter
Vm-dc(full)=2Vm(full)π
​Go RMS Output Voltage of Single Phase Full Converter
Vrms(full)=Vm(full)2
​Go Apparent Power for Constant Load Current
S(full)=IL(full)VL(full)

How to Evaluate Real Power for Constant Load Current?

Real Power for Constant Load Current evaluator uses Real Power Full Converter = Load Voltage Full Converter*Load Current Full converter*cos(Firing Angle Full Converter) to evaluate the Real Power Full Converter, The Real power for constant load current formula is defined as average power in watts delivered to a load. It is the only useful power. It is the actual power dissipated by the load. In this case, the load current is constant because the load is highly inductive. Real Power Full Converter is denoted by P(full) symbol.

How to evaluate Real Power for Constant Load Current using this online evaluator? To use this online evaluator for Real Power for Constant Load Current, enter Load Voltage Full Converter (VL(full)), Load Current Full converter (IL(full)) & Firing Angle Full Converter full) and hit the calculate button.

FAQs on Real Power for Constant Load Current

What is the formula to find Real Power for Constant Load Current?
The formula of Real Power for Constant Load Current is expressed as Real Power Full Converter = Load Voltage Full Converter*Load Current Full converter*cos(Firing Angle Full Converter). Here is an example- 42.86826 = 99*0.5*cos(0.610865238197901).
How to calculate Real Power for Constant Load Current?
With Load Voltage Full Converter (VL(full)), Load Current Full converter (IL(full)) & Firing Angle Full Converter full) we can find Real Power for Constant Load Current using the formula - Real Power Full Converter = Load Voltage Full Converter*Load Current Full converter*cos(Firing Angle Full Converter). This formula also uses Cosine (cos) function(s).
Can the Real Power for Constant Load Current be negative?
Yes, the Real Power for Constant Load Current, measured in Power can be negative.
Which unit is used to measure Real Power for Constant Load Current?
Real Power for Constant Load Current is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Real Power for Constant Load Current can be measured.
Copied!