Reactance of Secondary Winding in Primary Formula

Fx Copy
LaTeX Copy
The Reactance of Secondary in Primary is the reactance of secondary winding in primary. Check FAQs
X'2=XL2K2
X'2 - Reactance of Secondary in Primary?XL2 - Secondary Leakage Reactance?K - Transformation Ratio?

Reactance of Secondary Winding in Primary Example

With values
With units
Only example

Here is how the Reactance of Secondary Winding in Primary equation looks like with Values.

Here is how the Reactance of Secondary Winding in Primary equation looks like with Units.

Here is how the Reactance of Secondary Winding in Primary equation looks like.

0.6597Edit=0.95Edit1.2Edit2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Reactance of Secondary Winding in Primary

Reactance of Secondary Winding in Primary Solution

Follow our step by step solution on how to calculate Reactance of Secondary Winding in Primary?

FIRST Step Consider the formula
X'2=XL2K2
Next Step Substitute values of Variables
X'2=0.95Ω1.22
Next Step Prepare to Evaluate
X'2=0.951.22
Next Step Evaluate
X'2=0.659722222222222Ω
LAST Step Rounding Answer
X'2=0.6597Ω

Reactance of Secondary Winding in Primary Formula Elements

Variables
Reactance of Secondary in Primary
The Reactance of Secondary in Primary is the reactance of secondary winding in primary.
Symbol: X'2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Secondary Leakage Reactance
Secondary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding.
Symbol: XL2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Transformation Ratio
The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Reactance category

​Go Equivalent Reactance of Transformer from Primary Side
X01=XL1+X'2
​Go Equivalent Reactance of Transformer from Secondary Side
X02=XL2+X'1
​Go Primary Leakage Reactance
XL1=X'1K2
​Go Reactance of Primary Winding in Secondary
X'1=XL1K2

How to Evaluate Reactance of Secondary Winding in Primary?

Reactance of Secondary Winding in Primary evaluator uses Reactance of Secondary in Primary = Secondary Leakage Reactance/(Transformation Ratio^2) to evaluate the Reactance of Secondary in Primary, The Reactance of Secondary Winding in Primary formula is defined as the reactance that is in primary winding because of the secondary winding. Reactance of Secondary in Primary is denoted by X'2 symbol.

How to evaluate Reactance of Secondary Winding in Primary using this online evaluator? To use this online evaluator for Reactance of Secondary Winding in Primary, enter Secondary Leakage Reactance (XL2) & Transformation Ratio (K) and hit the calculate button.

FAQs on Reactance of Secondary Winding in Primary

What is the formula to find Reactance of Secondary Winding in Primary?
The formula of Reactance of Secondary Winding in Primary is expressed as Reactance of Secondary in Primary = Secondary Leakage Reactance/(Transformation Ratio^2). Here is an example- 0.659722 = 0.95/(1.2^2).
How to calculate Reactance of Secondary Winding in Primary?
With Secondary Leakage Reactance (XL2) & Transformation Ratio (K) we can find Reactance of Secondary Winding in Primary using the formula - Reactance of Secondary in Primary = Secondary Leakage Reactance/(Transformation Ratio^2).
Can the Reactance of Secondary Winding in Primary be negative?
Yes, the Reactance of Secondary Winding in Primary, measured in Electric Resistance can be negative.
Which unit is used to measure Reactance of Secondary Winding in Primary?
Reactance of Secondary Winding in Primary is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Reactance of Secondary Winding in Primary can be measured.
Copied!