Fx Copy
LaTeX Copy
The Ratio of Discharge in Overflow to Underflow is the ratio of the solution, solvent or solute discharge in the overflow to that in the underflow. Check FAQs
R=VW
R - Ratio of Discharge in Overflow to Underflow?V - Amount of Solution Discharge in Overflow?W - Amount of Solution Discharge in Underflow?

Ratio of Solution Discharged in Overflow to Underflow Example

With values
With units
Only example

Here is how the Ratio of Solution Discharged in Overflow to Underflow equation looks like with Values.

Here is how the Ratio of Solution Discharged in Overflow to Underflow equation looks like with Units.

Here is how the Ratio of Solution Discharged in Overflow to Underflow equation looks like.

1.3467Edit=1.01Edit0.75Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Ratio of Solution Discharged in Overflow to Underflow

Ratio of Solution Discharged in Overflow to Underflow Solution

Follow our step by step solution on how to calculate Ratio of Solution Discharged in Overflow to Underflow?

FIRST Step Consider the formula
R=VW
Next Step Substitute values of Variables
R=1.01kg/s0.75kg/s
Next Step Prepare to Evaluate
R=1.010.75
Next Step Evaluate
R=1.34666666666667
LAST Step Rounding Answer
R=1.3467

Ratio of Solution Discharged in Overflow to Underflow Formula Elements

Variables
Ratio of Discharge in Overflow to Underflow
The Ratio of Discharge in Overflow to Underflow is the ratio of the solution, solvent or solute discharge in the overflow to that in the underflow.
Symbol: R
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Amount of Solution Discharge in Overflow
The Amount of Solution Discharge in Overflow is the amount of the solution discharged in the Overflow of the continuous leaching operation.
Symbol: V
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Amount of Solution Discharge in Underflow
The Amount of Solution Discharge in Underflow is the amount of the solution discharged in the Underflow of the continuous leaching operation.
Symbol: W
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.

Other Formulas to find Ratio of Discharge in Overflow to Underflow

​Go Ratio of Solute Discharged in Underflow to Overflow
R=LS
​Go Ratio of Solvent Discharged in Underflow to Overflow
R=V-LW-S

Other formulas in Counter Current Continuous Leaching for Constant Overflow (Pure Solvent) category

​Go Area of Contact for Batch Leaching Operation
A=(-VLeachingKLt)ln((CS-CCS))
​Go Concentration of Solute in Bulk Solution at Time t for Batch Leaching
C=CS(1-exp(-KLAtVLeaching))
​Go Time of Batch Leaching Operation
t=(-VLeachingAKL)ln((CS-CCS))
​Go Volume of Leaching Solution in Batch Leaching
VLeaching=-KLAtln((CS-CCS))

How to Evaluate Ratio of Solution Discharged in Overflow to Underflow?

Ratio of Solution Discharged in Overflow to Underflow evaluator uses Ratio of Discharge in Overflow to Underflow = Amount of Solution Discharge in Overflow/Amount of Solution Discharge in Underflow to evaluate the Ratio of Discharge in Overflow to Underflow, The Ratio of Solution Discharged in Overflow to Underflow formula is defined as the ratio of the discharge in underflow to overflow of the solution flowrate in Leaching Operation. Ratio of Discharge in Overflow to Underflow is denoted by R symbol.

How to evaluate Ratio of Solution Discharged in Overflow to Underflow using this online evaluator? To use this online evaluator for Ratio of Solution Discharged in Overflow to Underflow, enter Amount of Solution Discharge in Overflow (V) & Amount of Solution Discharge in Underflow (W) and hit the calculate button.

FAQs on Ratio of Solution Discharged in Overflow to Underflow

What is the formula to find Ratio of Solution Discharged in Overflow to Underflow?
The formula of Ratio of Solution Discharged in Overflow to Underflow is expressed as Ratio of Discharge in Overflow to Underflow = Amount of Solution Discharge in Overflow/Amount of Solution Discharge in Underflow. Here is an example- 1.346667 = 1.01/0.75.
How to calculate Ratio of Solution Discharged in Overflow to Underflow?
With Amount of Solution Discharge in Overflow (V) & Amount of Solution Discharge in Underflow (W) we can find Ratio of Solution Discharged in Overflow to Underflow using the formula - Ratio of Discharge in Overflow to Underflow = Amount of Solution Discharge in Overflow/Amount of Solution Discharge in Underflow.
What are the other ways to Calculate Ratio of Discharge in Overflow to Underflow?
Here are the different ways to Calculate Ratio of Discharge in Overflow to Underflow-
  • Ratio of Discharge in Overflow to Underflow=Amount of Solute Discharge in Overflow/Amount of Solute Discharge in UnderflowOpenImg
  • Ratio of Discharge in Overflow to Underflow=(Amount of Solution Discharge in Overflow-Amount of Solute Discharge in Overflow)/(Amount of Solution Discharge in Underflow-Amount of Solute Discharge in Underflow)OpenImg
Copied!