Fx Copy
LaTeX Copy
The Rate of Heat Generation in Secondary Shear Zone is the rate of heat generation in the area surrounding the chip tool contact region. Check FAQs
Pf=Pc-Ps
Pf - Rate of Heat Generation in Secondary Shear Zone?Pc - Rate of Energy Consumption During Machining?Ps - Rate of Heat Generation in Primary Shear Zone?

Rate of Heat Generation in Secondary Deformation Zone Example

With values
With units
Only example

Here is how the Rate of Heat Generation in Secondary Deformation Zone equation looks like with Values.

Here is how the Rate of Heat Generation in Secondary Deformation Zone equation looks like with Units.

Here is how the Rate of Heat Generation in Secondary Deformation Zone equation looks like.

400Edit=1780Edit-1380Edit
You are here -
HomeIcon Home » Category Engineering » Category Production Engineering » Category Metal Machining » fx Rate of Heat Generation in Secondary Deformation Zone

Rate of Heat Generation in Secondary Deformation Zone Solution

Follow our step by step solution on how to calculate Rate of Heat Generation in Secondary Deformation Zone?

FIRST Step Consider the formula
Pf=Pc-Ps
Next Step Substitute values of Variables
Pf=1780W-1380W
Next Step Prepare to Evaluate
Pf=1780-1380
LAST Step Evaluate
Pf=400W

Rate of Heat Generation in Secondary Deformation Zone Formula Elements

Variables
Rate of Heat Generation in Secondary Shear Zone
The Rate of Heat Generation in Secondary Shear Zone is the rate of heat generation in the area surrounding the chip tool contact region.
Symbol: Pf
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Rate of Energy Consumption During Machining
Rate of Energy Consumption during Machining is the amount of energy transferred or converted per unit of time by the machine to the workpiece.
Symbol: Pc
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Rate of Heat Generation in Primary Shear Zone
The Rate of Heat Generation in Primary Shear Zone is the heat transfer rate in the narrow zone surrounding the shear plane in machining.
Symbol: Ps
Measurement: PowerUnit: W
Note: Value should be greater than 0.

Other Formulas to find Rate of Heat Generation in Secondary Shear Zone

​Go Rate of Heat generated in Secondary Shear Zone given Average Temperature
Pf=(θfCρwpVcutacdcut)

Other formulas in Heat Conduction Rate category

​Go Rate of Heat Conduction into Workpiece given Total Rate of Heat Generation
Φw=Pm-Φc-Φt
​Go Rate of Heat Conduction into Tool given Total Rate of Heat Generation
Φt=Pm-Φc-Φw
​Go Rate of Heat Transportation by Chip given Total Rate of Heat Generation
Φc=Pm-Φw-Φt
​Go Rate of Energy Consumption using Rate of Heat Generation during Machining
Pc=Ps+Pf

How to Evaluate Rate of Heat Generation in Secondary Deformation Zone?

Rate of Heat Generation in Secondary Deformation Zone evaluator uses Rate of Heat Generation in Secondary Shear Zone = Rate of Energy Consumption During Machining-Rate of Heat Generation in Primary Shear Zone to evaluate the Rate of Heat Generation in Secondary Shear Zone, Rate of Heat Generation in Secondary Deformation Zone is the heat generated in the narrow zone surrounding the shear plane in machining. Rate of Heat Generation in Secondary Shear Zone is denoted by Pf symbol.

How to evaluate Rate of Heat Generation in Secondary Deformation Zone using this online evaluator? To use this online evaluator for Rate of Heat Generation in Secondary Deformation Zone, enter Rate of Energy Consumption During Machining (Pc) & Rate of Heat Generation in Primary Shear Zone (Ps) and hit the calculate button.

FAQs on Rate of Heat Generation in Secondary Deformation Zone

What is the formula to find Rate of Heat Generation in Secondary Deformation Zone?
The formula of Rate of Heat Generation in Secondary Deformation Zone is expressed as Rate of Heat Generation in Secondary Shear Zone = Rate of Energy Consumption During Machining-Rate of Heat Generation in Primary Shear Zone. Here is an example- 400 = 1780-1380.
How to calculate Rate of Heat Generation in Secondary Deformation Zone?
With Rate of Energy Consumption During Machining (Pc) & Rate of Heat Generation in Primary Shear Zone (Ps) we can find Rate of Heat Generation in Secondary Deformation Zone using the formula - Rate of Heat Generation in Secondary Shear Zone = Rate of Energy Consumption During Machining-Rate of Heat Generation in Primary Shear Zone.
What are the other ways to Calculate Rate of Heat Generation in Secondary Shear Zone?
Here are the different ways to Calculate Rate of Heat Generation in Secondary Shear Zone-
  • Rate of Heat Generation in Secondary Shear Zone=(Average Temp Rise of Chip in Secondary Shear Zone*Specific Heat Capacity of Workpiece*Density of Work Piece*Cutting Speed*Undeformed Chip Thickness*Depth of Cut)OpenImg
Can the Rate of Heat Generation in Secondary Deformation Zone be negative?
No, the Rate of Heat Generation in Secondary Deformation Zone, measured in Power cannot be negative.
Which unit is used to measure Rate of Heat Generation in Secondary Deformation Zone?
Rate of Heat Generation in Secondary Deformation Zone is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Rate of Heat Generation in Secondary Deformation Zone can be measured.
Copied!