Rate of Flow of Water through Saturated Soil by Darcy's Law Formula

Fx Copy
LaTeX Copy
Rate of Flow of Water through Soil is the rate at which a water flows through a particular channel, pipe, etc. Check FAQs
qflow=(kiAcs)
qflow - Rate of Flow of Water through Soil?k - Coefficient of Permeability?i - Hydraulic Gradient in Soil?Acs - Cross Sectional Area in Permeability?

Rate of Flow of Water through Saturated Soil by Darcy's Law Example

With values
With units
Only example

Here is how the Rate of Flow of Water through Saturated Soil by Darcy's Law equation looks like with Values.

Here is how the Rate of Flow of Water through Saturated Soil by Darcy's Law equation looks like with Units.

Here is how the Rate of Flow of Water through Saturated Soil by Darcy's Law equation looks like.

25.8687Edit=(0.99Edit2.01Edit13Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Geotechnical Engineering » fx Rate of Flow of Water through Saturated Soil by Darcy's Law

Rate of Flow of Water through Saturated Soil by Darcy's Law Solution

Follow our step by step solution on how to calculate Rate of Flow of Water through Saturated Soil by Darcy's Law?

FIRST Step Consider the formula
qflow=(kiAcs)
Next Step Substitute values of Variables
qflow=(0.99m/s2.0113)
Next Step Prepare to Evaluate
qflow=(0.992.0113)
LAST Step Evaluate
qflow=25.8687m³/s

Rate of Flow of Water through Saturated Soil by Darcy's Law Formula Elements

Variables
Rate of Flow of Water through Soil
Rate of Flow of Water through Soil is the rate at which a water flows through a particular channel, pipe, etc.
Symbol: qflow
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Coefficient of Permeability
Coefficient of Permeability is a measure of a soil's ability to allow water to flow through its pores. Essential in the design of retaining walls, cutoff walls, and other seepage control measures.
Symbol: k
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Hydraulic Gradient in Soil
Hydraulic Gradient in Soil is the driving force that causes groundwater to move in the direction of maximum decreasing total head.
Symbol: i
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Cross Sectional Area in Permeability
Cross Sectional Area in Permeability is the surface area perpendicular to the direction of fluid flow through which the fluid moves. It is important in the design of hydraulic structures such as dams.
Symbol: Acs
Measurement: AreaUnit:
Note: Value should be greater than 0.

Other formulas in Soil Compaction Test category

​Go Volume of Soil for Sand Filling in Sand Cone Method
V=(Wtρ)
​Go Weight of Sand Filling Hole in Sand Cone Method
Wt=(Vρ)
​Go Density of Sand given Volume of Soil for Sand Filling in Sand Cone Method
ρ=(WtV)
​Go Percent Moisture in Sand Cone Method
Msc=100(Wm-Wd)Wd

How to Evaluate Rate of Flow of Water through Saturated Soil by Darcy's Law?

Rate of Flow of Water through Saturated Soil by Darcy's Law evaluator uses Rate of Flow of Water through Soil = (Coefficient of Permeability*Hydraulic Gradient in Soil*Cross Sectional Area in Permeability) to evaluate the Rate of Flow of Water through Soil, The Rate of Flow of Water through Saturated Soil by Darcy's Law formula is defined as the flow of a fluid through a porous medium. For geotechnical engineering, it is commonly used to describe the movement of water through soil. Rate of Flow of Water through Soil is denoted by qflow symbol.

How to evaluate Rate of Flow of Water through Saturated Soil by Darcy's Law using this online evaluator? To use this online evaluator for Rate of Flow of Water through Saturated Soil by Darcy's Law, enter Coefficient of Permeability (k), Hydraulic Gradient in Soil (i) & Cross Sectional Area in Permeability (Acs) and hit the calculate button.

FAQs on Rate of Flow of Water through Saturated Soil by Darcy's Law

What is the formula to find Rate of Flow of Water through Saturated Soil by Darcy's Law?
The formula of Rate of Flow of Water through Saturated Soil by Darcy's Law is expressed as Rate of Flow of Water through Soil = (Coefficient of Permeability*Hydraulic Gradient in Soil*Cross Sectional Area in Permeability). Here is an example- 25.8687 = (0.99*2.01*13).
How to calculate Rate of Flow of Water through Saturated Soil by Darcy's Law?
With Coefficient of Permeability (k), Hydraulic Gradient in Soil (i) & Cross Sectional Area in Permeability (Acs) we can find Rate of Flow of Water through Saturated Soil by Darcy's Law using the formula - Rate of Flow of Water through Soil = (Coefficient of Permeability*Hydraulic Gradient in Soil*Cross Sectional Area in Permeability).
Can the Rate of Flow of Water through Saturated Soil by Darcy's Law be negative?
Yes, the Rate of Flow of Water through Saturated Soil by Darcy's Law, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Rate of Flow of Water through Saturated Soil by Darcy's Law?
Rate of Flow of Water through Saturated Soil by Darcy's Law is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Rate of Flow of Water through Saturated Soil by Darcy's Law can be measured.