Rate of Discharge of Water Flowing Past Waste Valve Formula

Fx Copy
LaTeX Copy
Discharge of Water Flowing Past Waste Valve is the rate of water flow past the waste valve in a hydraulic ram system during operation. Check FAQs
Qwv=π4ds2Vmax2t1t
Qwv - Discharge of Water Flowing Past Waste Valve?ds - Diameter of Supply Pipe in Ram?Vmax - Maximum Velocity in Supply Pipe of Ram?t1 - Time to Build Maximum Velocity in Supply Pipe?t - Total Time for One Cycle of Ram?π - Archimedes' constant?

Rate of Discharge of Water Flowing Past Waste Valve Example

With values
With units
Only example

Here is how the Rate of Discharge of Water Flowing Past Waste Valve equation looks like with Values.

Here is how the Rate of Discharge of Water Flowing Past Waste Valve equation looks like with Units.

Here is how the Rate of Discharge of Water Flowing Past Waste Valve equation looks like.

0.0029Edit=3.141640.075Edit21.5555Edit21.2353Edit1.4593Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Fluid Mechanics » fx Rate of Discharge of Water Flowing Past Waste Valve

Rate of Discharge of Water Flowing Past Waste Valve Solution

Follow our step by step solution on how to calculate Rate of Discharge of Water Flowing Past Waste Valve?

FIRST Step Consider the formula
Qwv=π4ds2Vmax2t1t
Next Step Substitute values of Variables
Qwv=π40.075m21.5555m/s21.2353s1.4593s
Next Step Substitute values of Constants
Qwv=3.141640.075m21.5555m/s21.2353s1.4593s
Next Step Prepare to Evaluate
Qwv=3.141640.07521.555521.23531.4593
Next Step Evaluate
Qwv=0.00290858496875951m³/s
LAST Step Rounding Answer
Qwv=0.0029m³/s

Rate of Discharge of Water Flowing Past Waste Valve Formula Elements

Variables
Constants
Discharge of Water Flowing Past Waste Valve
Discharge of Water Flowing Past Waste Valve is the rate of water flow past the waste valve in a hydraulic ram system during operation.
Symbol: Qwv
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Diameter of Supply Pipe in Ram
Diameter of Supply Pipe in Ram is the diameter of the pipe that supplies water to the hydraulic ram, affecting its overall performance and efficiency.
Symbol: ds
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Maximum Velocity in Supply Pipe of Ram
Maximum Velocity in Supply Pipe of Ram is the highest speed of fluid flowing through the supply pipe of a hydraulic ram during its operation.
Symbol: Vmax
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Time to Build Maximum Velocity in Supply Pipe
Time to Build Maximum Velocity in Supply Pipe is the duration required for the supply pipe to reach its maximum velocity in a hydraulic ram system.
Symbol: t1
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Total Time for One Cycle of Ram
Total Time for One Cycle of Ram is the time taken by the hydraulic ram to complete one cycle of its operation.
Symbol: t
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Hydraulic Ram category

​Go Aubuisson's Efficiency of Hydraulic Ram
ηd=qHQh
​Go Rankine's Efficiency of Hydraulic Ram
ηr=q(H-h)h(Q-q)
​Go Rate of Discharge of Water Actually Lifted by Ram
qa=π4ds2Vmax2t2t
​Go Total Time for One Cycle of Hydraulic Ram
t=lsVmax[g](1h+1H-h)

How to Evaluate Rate of Discharge of Water Flowing Past Waste Valve?

Rate of Discharge of Water Flowing Past Waste Valve evaluator uses Discharge of Water Flowing Past Waste Valve = pi/4*Diameter of Supply Pipe in Ram^2*Maximum Velocity in Supply Pipe of Ram/2*Time to Build Maximum Velocity in Supply Pipe/Total Time for One Cycle of Ram to evaluate the Discharge of Water Flowing Past Waste Valve, Rate of Discharge of Water Flowing Past Waste Valve formula is defined as the volumetric flow rate of water flowing past a waste valve in a hydraulic system, which is a critical parameter in hydraulic actuator and motor design, as it affects the system's overall performance and efficiency. Discharge of Water Flowing Past Waste Valve is denoted by Qwv symbol.

How to evaluate Rate of Discharge of Water Flowing Past Waste Valve using this online evaluator? To use this online evaluator for Rate of Discharge of Water Flowing Past Waste Valve, enter Diameter of Supply Pipe in Ram (ds), Maximum Velocity in Supply Pipe of Ram (Vmax), Time to Build Maximum Velocity in Supply Pipe (t1) & Total Time for One Cycle of Ram (t) and hit the calculate button.

FAQs on Rate of Discharge of Water Flowing Past Waste Valve

What is the formula to find Rate of Discharge of Water Flowing Past Waste Valve?
The formula of Rate of Discharge of Water Flowing Past Waste Valve is expressed as Discharge of Water Flowing Past Waste Valve = pi/4*Diameter of Supply Pipe in Ram^2*Maximum Velocity in Supply Pipe of Ram/2*Time to Build Maximum Velocity in Supply Pipe/Total Time for One Cycle of Ram. Here is an example- 0.002909 = pi/4*0.075^2*1.555488/2*1.235279/1.459259.
How to calculate Rate of Discharge of Water Flowing Past Waste Valve?
With Diameter of Supply Pipe in Ram (ds), Maximum Velocity in Supply Pipe of Ram (Vmax), Time to Build Maximum Velocity in Supply Pipe (t1) & Total Time for One Cycle of Ram (t) we can find Rate of Discharge of Water Flowing Past Waste Valve using the formula - Discharge of Water Flowing Past Waste Valve = pi/4*Diameter of Supply Pipe in Ram^2*Maximum Velocity in Supply Pipe of Ram/2*Time to Build Maximum Velocity in Supply Pipe/Total Time for One Cycle of Ram. This formula also uses Archimedes' constant .
Can the Rate of Discharge of Water Flowing Past Waste Valve be negative?
No, the Rate of Discharge of Water Flowing Past Waste Valve, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Rate of Discharge of Water Flowing Past Waste Valve?
Rate of Discharge of Water Flowing Past Waste Valve is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Rate of Discharge of Water Flowing Past Waste Valve can be measured.
Copied!