Rate Constant for Zero Order Reaction for Plug Flow Formula

Fx Copy
LaTeX Copy
The Rate Constant for Zero Order Reaction is equal to the rate of the reaction because in a zero-order reaction the rate of reaction is proportional to zero power of the concentration of the reactant. Check FAQs
k0=XA-PFRCo pfr𝛕pfr
k0 - Rate Constant for Zero Order Reaction?XA-PFR - Reactant Conversion in PFR?Co pfr - Initial Reactant Concentration in PFR?𝛕pfr - Space Time in PFR?

Rate Constant for Zero Order Reaction for Plug Flow Example

With values
With units
Only example

Here is how the Rate Constant for Zero Order Reaction for Plug Flow equation looks like with Values.

Here is how the Rate Constant for Zero Order Reaction for Plug Flow equation looks like with Units.

Here is how the Rate Constant for Zero Order Reaction for Plug Flow equation looks like.

1170.4931Edit=0.715Edit82Edit0.0501Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Chemical Reaction Engineering » fx Rate Constant for Zero Order Reaction for Plug Flow

Rate Constant for Zero Order Reaction for Plug Flow Solution

Follow our step by step solution on how to calculate Rate Constant for Zero Order Reaction for Plug Flow?

FIRST Step Consider the formula
k0=XA-PFRCo pfr𝛕pfr
Next Step Substitute values of Variables
k0=0.71582mol/m³0.0501s
Next Step Prepare to Evaluate
k0=0.715820.0501
Next Step Evaluate
k0=1170.49311239768mol/m³*s
LAST Step Rounding Answer
k0=1170.4931mol/m³*s

Rate Constant for Zero Order Reaction for Plug Flow Formula Elements

Variables
Rate Constant for Zero Order Reaction
The Rate Constant for Zero Order Reaction is equal to the rate of the reaction because in a zero-order reaction the rate of reaction is proportional to zero power of the concentration of the reactant.
Symbol: k0
Measurement: Reaction RateUnit: mol/m³*s
Note: Value can be positive or negative.
Reactant Conversion in PFR
Reactant Conversion in PFR gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1.
Symbol: XA-PFR
Measurement: NAUnit: Unitless
Note: Value should be less than 1.
Initial Reactant Concentration in PFR
The Initial Reactant Concentration in PFR refers to the amount of reactant present in the solvent before the considered process.
Symbol: Co pfr
Measurement: Molar ConcentrationUnit: mol/m³
Note: Value should be greater than 0.
Space Time in PFR
Space Time in PFR is the time necessary to process volume of reactor fluid at the entrance conditions.
Symbol: 𝛕pfr
Measurement: TimeUnit: s
Note: Value should be greater than 0.

Other formulas in Plug Flow or Batch category

​Go Initial Reactant Concentration for Second Order Reaction for Mixed Flow
CoMixedFlow=(1𝛕MFRk'' MFR)(XMFR(1+(εXMFR))2(1-XMFR)2)
​Go Initial Reactant Concentration for Zero Order Reaction for Mixed Flow
Co-MFR=k0-MFR𝛕MFRXMFR
​Go Rate Constant for First Order Reaction for Mixed Flow
k1MFR=(1𝛕MFR)(XMFR(1+(εXMFR))1-XMFR)
​Go Rate Constant for Second Order Reaction for Mixed Flow
kMixedFlow''=(1𝛕MFRCo-MFR)(XMFR(1+(εXMFR))2(1-XMFR)2)

How to Evaluate Rate Constant for Zero Order Reaction for Plug Flow?

Rate Constant for Zero Order Reaction for Plug Flow evaluator uses Rate Constant for Zero Order Reaction = (Reactant Conversion in PFR*Initial Reactant Concentration in PFR)/Space Time in PFR to evaluate the Rate Constant for Zero Order Reaction, The Rate Constant for Zero Order Reaction for Plug Flow formula is defined as the rate of reaction for zero order reaction where fractional volume change is considerable. Rate Constant for Zero Order Reaction is denoted by k0 symbol.

How to evaluate Rate Constant for Zero Order Reaction for Plug Flow using this online evaluator? To use this online evaluator for Rate Constant for Zero Order Reaction for Plug Flow, enter Reactant Conversion in PFR (XA-PFR), Initial Reactant Concentration in PFR (Co pfr) & Space Time in PFR (𝛕pfr) and hit the calculate button.

FAQs on Rate Constant for Zero Order Reaction for Plug Flow

What is the formula to find Rate Constant for Zero Order Reaction for Plug Flow?
The formula of Rate Constant for Zero Order Reaction for Plug Flow is expressed as Rate Constant for Zero Order Reaction = (Reactant Conversion in PFR*Initial Reactant Concentration in PFR)/Space Time in PFR. Here is an example- 1141.944 = (0.715*82)/0.05009.
How to calculate Rate Constant for Zero Order Reaction for Plug Flow?
With Reactant Conversion in PFR (XA-PFR), Initial Reactant Concentration in PFR (Co pfr) & Space Time in PFR (𝛕pfr) we can find Rate Constant for Zero Order Reaction for Plug Flow using the formula - Rate Constant for Zero Order Reaction = (Reactant Conversion in PFR*Initial Reactant Concentration in PFR)/Space Time in PFR.
Can the Rate Constant for Zero Order Reaction for Plug Flow be negative?
Yes, the Rate Constant for Zero Order Reaction for Plug Flow, measured in Reaction Rate can be negative.
Which unit is used to measure Rate Constant for Zero Order Reaction for Plug Flow?
Rate Constant for Zero Order Reaction for Plug Flow is usually measured using the Mole per Cubic Meter Second[mol/m³*s] for Reaction Rate. Mole per Liter Second[mol/m³*s], Millimole per Liter Second[mol/m³*s] are the few other units in which Rate Constant for Zero Order Reaction for Plug Flow can be measured.
Copied!