Fx Copy
LaTeX Copy
The Rate Constant for First Order Reaction is defined as the rate of the reaction divided by the concentration of the reactant. Check FAQs
k'=(1𝛕mixed)(Xmfr1-Xmfr)
k' - Rate Constant for First Order Reaction?𝛕mixed - Space Time in Mixed Flow?Xmfr - Reactant Conversion in Mixed Flow?

Rate Constant for First Order Reaction using Space Time for Mixed Flow Example

With values
With units
Only example

Here is how the Rate Constant for First Order Reaction using Space Time for Mixed Flow equation looks like with Values.

Here is how the Rate Constant for First Order Reaction using Space Time for Mixed Flow equation looks like with Units.

Here is how the Rate Constant for First Order Reaction using Space Time for Mixed Flow equation looks like.

48.9655Edit=(10.05Edit)(0.71Edit1-0.71Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Chemical Reaction Engineering » fx Rate Constant for First Order Reaction using Space Time for Mixed Flow

Rate Constant for First Order Reaction using Space Time for Mixed Flow Solution

Follow our step by step solution on how to calculate Rate Constant for First Order Reaction using Space Time for Mixed Flow?

FIRST Step Consider the formula
k'=(1𝛕mixed)(Xmfr1-Xmfr)
Next Step Substitute values of Variables
k'=(10.05s)(0.711-0.71)
Next Step Prepare to Evaluate
k'=(10.05)(0.711-0.71)
Next Step Evaluate
k'=48.9655172413793s⁻¹
LAST Step Rounding Answer
k'=48.9655s⁻¹

Rate Constant for First Order Reaction using Space Time for Mixed Flow Formula Elements

Variables
Rate Constant for First Order Reaction
The Rate Constant for First Order Reaction is defined as the rate of the reaction divided by the concentration of the reactant.
Symbol: k'
Measurement: First Order Reaction Rate ConstantUnit: s⁻¹
Note: Value can be positive or negative.
Space Time in Mixed Flow
Space Time in Mixed Flow is the time necessary to process volume of reactor fluid at the entrance conditions.
Symbol: 𝛕mixed
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Reactant Conversion in Mixed Flow
Reactant Conversion in Mixed Flow gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1.
Symbol: Xmfr
Measurement: NAUnit: Unitless
Note: Value should be less than 1.

Other Formulas to find Rate Constant for First Order Reaction

​Go Rate Constant for First Order Reaction using Reactant Concentration for Mixed Flow
k'=(1𝛕mixed)(Co-CC)

Other formulas in Mixed Flow category

​Go Initial Reactant Concentration for Second Order Reaction using Space Time for Mixed Flow
Co=Xmfr(1-Xmfr)2(𝛕mixed)(kmixed)
​Go Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow
Co=kmixed flow𝛕mixedXmfr
​Go Rate Constant for Second Order Reaction using Reactant Concentration for Mixed Flow
kmixed=Co-C(𝛕mixed)(C)2
​Go Rate Constant for Second Order Reaction using Space Time for Mixed Flow
kmixed=Xmfr(1-Xmfr)2(𝛕mixed)(Co)

How to Evaluate Rate Constant for First Order Reaction using Space Time for Mixed Flow?

Rate Constant for First Order Reaction using Space Time for Mixed Flow evaluator uses Rate Constant for First Order Reaction = (1/Space Time in Mixed Flow)*(Reactant Conversion in Mixed Flow/(1-Reactant Conversion in Mixed Flow)) to evaluate the Rate Constant for First Order Reaction, The Rate Constant for First Order Reaction using Space Time for Mixed Flow formula is defined as the constant of proportionality which gives the relation between rate of reaction and the first power of concentration of one of the reactants for mixed flow. Rate Constant for First Order Reaction is denoted by k' symbol.

How to evaluate Rate Constant for First Order Reaction using Space Time for Mixed Flow using this online evaluator? To use this online evaluator for Rate Constant for First Order Reaction using Space Time for Mixed Flow, enter Space Time in Mixed Flow (𝛕mixed) & Reactant Conversion in Mixed Flow (Xmfr) and hit the calculate button.

FAQs on Rate Constant for First Order Reaction using Space Time for Mixed Flow

What is the formula to find Rate Constant for First Order Reaction using Space Time for Mixed Flow?
The formula of Rate Constant for First Order Reaction using Space Time for Mixed Flow is expressed as Rate Constant for First Order Reaction = (1/Space Time in Mixed Flow)*(Reactant Conversion in Mixed Flow/(1-Reactant Conversion in Mixed Flow)). Here is an example- 48.96552 = (1/0.05)*(0.71/(1-0.71)).
How to calculate Rate Constant for First Order Reaction using Space Time for Mixed Flow?
With Space Time in Mixed Flow (𝛕mixed) & Reactant Conversion in Mixed Flow (Xmfr) we can find Rate Constant for First Order Reaction using Space Time for Mixed Flow using the formula - Rate Constant for First Order Reaction = (1/Space Time in Mixed Flow)*(Reactant Conversion in Mixed Flow/(1-Reactant Conversion in Mixed Flow)).
What are the other ways to Calculate Rate Constant for First Order Reaction?
Here are the different ways to Calculate Rate Constant for First Order Reaction-
  • Rate Constant for First Order Reaction=(1/Space Time in Mixed Flow)*((Initial Reactant Concentration in Mixed Flow-Reactant Concentration at given Time)/Reactant Concentration at given Time)OpenImg
Can the Rate Constant for First Order Reaction using Space Time for Mixed Flow be negative?
Yes, the Rate Constant for First Order Reaction using Space Time for Mixed Flow, measured in First Order Reaction Rate Constant can be negative.
Which unit is used to measure Rate Constant for First Order Reaction using Space Time for Mixed Flow?
Rate Constant for First Order Reaction using Space Time for Mixed Flow is usually measured using the 1 Per Second[s⁻¹] for First Order Reaction Rate Constant. 1 Per Millisecond[s⁻¹], 1 Per Day[s⁻¹], 1 Per Hour[s⁻¹] are the few other units in which Rate Constant for First Order Reaction using Space Time for Mixed Flow can be measured.
Copied!