Radius of Well given Discharge is the radial distance from the center of the well to the outer boundary of the aquifer, where the effects of pumping or water withdrawal are observed. Check FAQs
rw=Rw102.72Tenvi(Hi-hw)Q0
rw - Radius of Well given Discharge?Rw - Radius of Influence?Tenvi - Coefficient of Transmissibility?Hi - Initial Aquifer Thickness?hw - Depth of Water?Q0 - Discharge at Time t=0?

Radius of Well given Coefficient of Transmissibility with Base 10 Example

With values
With units
Only example

Here is how the Radius of Well given Coefficient of Transmissibility with Base 10 equation looks like with Values.

Here is how the Radius of Well given Coefficient of Transmissibility with Base 10 equation looks like with Units.

Here is how the Radius of Well given Coefficient of Transmissibility with Base 10 equation looks like.

8.5356Edit=8.6Edit102.721.5Edit(2.48Edit-2.44Edit)50Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Radius of Well given Coefficient of Transmissibility with Base 10

Radius of Well given Coefficient of Transmissibility with Base 10 Solution

Follow our step by step solution on how to calculate Radius of Well given Coefficient of Transmissibility with Base 10?

FIRST Step Consider the formula
rw=Rw102.72Tenvi(Hi-hw)Q0
Next Step Substitute values of Variables
rw=8.6m102.721.5m²/s(2.48m-2.44m)50m³/s
Next Step Prepare to Evaluate
rw=8.6102.721.5(2.48-2.44)50
Next Step Evaluate
rw=8.53560779275538m
LAST Step Rounding Answer
rw=8.5356m

Radius of Well given Coefficient of Transmissibility with Base 10 Formula Elements

Variables
Radius of Well given Discharge
Radius of Well given Discharge is the radial distance from the center of the well to the outer boundary of the aquifer, where the effects of pumping or water withdrawal are observed.
Symbol: rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Influence
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Symbol: Rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Coefficient of Transmissibility
Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Symbol: Tenvi
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Initial Aquifer Thickness
Initial Aquifer Thickness is the aquifer thickness at initial stage before pumping.
Symbol: Hi
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Depth of Water
Depth of Water is the depth in the well measured above the impermeable layer.
Symbol: hw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge at Time t=0
Discharge at Time t=0 is the rate of flow of a liquid that moves over a designated point over a fixed period.
Symbol: Q0
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other Formulas to find Radius of Well given Discharge

​Go Radius of Well given Discharge in Confined Aquifer
rw=Rwexp(2πKWHbp(Hi-hw)Q0)
​Go Radius of Well for Discharge in Confined Aquifer with Base 10
rw=Rw102.72Kswhb(Hi-hw)Q
​Go Radius of Well given Coefficient of Transmissibility
rw=Rwexp(2πTenvi(Hi-hw)Q0)

Other formulas in Radial Distance and Radius of well category

​Go Radius of Well given Confined Aquifer Discharge
r'=Rwexp(2πKWHbpstQ)
​Go Radius of Well given Confined Aquifer Discharge with Base 10
r'=Rw102.72KWHbpstQ
​Go Radius of Well given Drawdown at Well
r''=Rwexp(2πTenvistQ)
​Go Radius of Well given Drawdown at Well with Base 10
r''=Rw102.72TenvistQ

How to Evaluate Radius of Well given Coefficient of Transmissibility with Base 10?

Radius of Well given Coefficient of Transmissibility with Base 10 evaluator uses Radius of Well given Discharge = Radius of Influence/10^((2.72*Coefficient of Transmissibility*(Initial Aquifer Thickness-Depth of Water))/Discharge at Time t=0) to evaluate the Radius of Well given Discharge, The Radius of Well given Coefficient of Transmissibility with Base 10 formula is defined as the value of radius of well when we have prior information of coefficient of transmissibility. Radius of Well given Discharge is denoted by rw symbol.

How to evaluate Radius of Well given Coefficient of Transmissibility with Base 10 using this online evaluator? To use this online evaluator for Radius of Well given Coefficient of Transmissibility with Base 10, enter Radius of Influence (Rw), Coefficient of Transmissibility (Tenvi), Initial Aquifer Thickness (Hi), Depth of Water (hw) & Discharge at Time t=0 (Q0) and hit the calculate button.

FAQs on Radius of Well given Coefficient of Transmissibility with Base 10

What is the formula to find Radius of Well given Coefficient of Transmissibility with Base 10?
The formula of Radius of Well given Coefficient of Transmissibility with Base 10 is expressed as Radius of Well given Discharge = Radius of Influence/10^((2.72*Coefficient of Transmissibility*(Initial Aquifer Thickness-Depth of Water))/Discharge at Time t=0). Here is an example- 8.535608 = 8.6/10^((2.72*1.5*(2.48-2.44))/50).
How to calculate Radius of Well given Coefficient of Transmissibility with Base 10?
With Radius of Influence (Rw), Coefficient of Transmissibility (Tenvi), Initial Aquifer Thickness (Hi), Depth of Water (hw) & Discharge at Time t=0 (Q0) we can find Radius of Well given Coefficient of Transmissibility with Base 10 using the formula - Radius of Well given Discharge = Radius of Influence/10^((2.72*Coefficient of Transmissibility*(Initial Aquifer Thickness-Depth of Water))/Discharge at Time t=0).
What are the other ways to Calculate Radius of Well given Discharge?
Here are the different ways to Calculate Radius of Well given Discharge-
  • Radius of Well given Discharge=Radius of Influence/exp((2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*(Initial Aquifer Thickness-Depth of Water))/Discharge at Time t=0)OpenImg
  • Radius of Well given Discharge=Radius of Influence/(10^(2.72*Standard Coefficient of Permeability*Thickness of Aquifer*(Initial Aquifer Thickness-Depth of Water))/Discharge)OpenImg
  • Radius of Well given Discharge=Radius of Influence/exp((2*pi*Coefficient of Transmissibility*(Initial Aquifer Thickness-Depth of Water))/Discharge at Time t=0)OpenImg
Can the Radius of Well given Coefficient of Transmissibility with Base 10 be negative?
No, the Radius of Well given Coefficient of Transmissibility with Base 10, measured in Length cannot be negative.
Which unit is used to measure Radius of Well given Coefficient of Transmissibility with Base 10?
Radius of Well given Coefficient of Transmissibility with Base 10 is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Radius of Well given Coefficient of Transmissibility with Base 10 can be measured.
Copied!