Fx Copy
LaTeX Copy
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table. Check FAQs
Rw=r102.72KWHbpstQli
Rw - Radius of Influence?r - Radius of Well?KWH - Coefficient of Permeability in Well Hydraulics?bp - Aquifer Thickness During Pumping?st - Total Drawdown?Qli - Discharge of Liquid?

Radius of Influence given Confined Aquifer Discharge with Base 10 Example

With values
With units
Only example

Here is how the Radius of Influence given Confined Aquifer Discharge with Base 10 equation looks like with Values.

Here is how the Radius of Influence given Confined Aquifer Discharge with Base 10 equation looks like with Units.

Here is how the Radius of Influence given Confined Aquifer Discharge with Base 10 equation looks like.

8.1392Edit=7.5Edit102.7210Edit2.36Edit0.83Edit15Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Radius of Influence given Confined Aquifer Discharge with Base 10

Radius of Influence given Confined Aquifer Discharge with Base 10 Solution

Follow our step by step solution on how to calculate Radius of Influence given Confined Aquifer Discharge with Base 10?

FIRST Step Consider the formula
Rw=r102.72KWHbpstQli
Next Step Substitute values of Variables
Rw=7.5m102.7210cm/s2.36m0.83m15m³/s
Next Step Convert Units
Rw=7.5m102.720.1m/s2.36m0.83m15m³/s
Next Step Prepare to Evaluate
Rw=7.5102.720.12.360.8315
Next Step Evaluate
Rw=8.13918344099956m
LAST Step Rounding Answer
Rw=8.1392m

Radius of Influence given Confined Aquifer Discharge with Base 10 Formula Elements

Variables
Radius of Influence
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Symbol: Rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Well
Radius of Well is defined as the distance from center of well to its outer boundary.
Symbol: r
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Coefficient of Permeability in Well Hydraulics
Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil.
Symbol: KWH
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Aquifer Thickness During Pumping
Aquifer Thickness During Pumping is the thickness of aquifer during pumping stage.
Symbol: bp
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Total Drawdown
The Total Drawdown is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Symbol: st
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Discharge of Liquid
Discharge of Liquid is the rate of flow of a liquid.
Symbol: Qli
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.

Other Formulas to find Radius of Influence

​Go Radius of Influence given Confined Aquifer Discharge
Rw=rexp(2πKWHbpstQli)

Other formulas in Radius of Influence category

​Go Radius of Influence given Discharge in Confined Aquifer
Rid=rexp(2πKWHbp(Hi-hw)Q0)
​Go Radius of Influence given Discharge in Confined Aquifer with Base 10
Rid=r102.72KWHbp(Hi-hw)Q0
​Go Radius of Influence given Coefficient of Transmissibility
ric=rexp(2πTenvi(Hi-hw)Q0)
​Go Radius of Influence given Coefficient of Transmissibility with Base 10
ric=r102.72Tenvi(Hi-hw)Qli

How to Evaluate Radius of Influence given Confined Aquifer Discharge with Base 10?

Radius of Influence given Confined Aquifer Discharge with Base 10 evaluator uses Radius of Influence = Radius of Well*10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*Total Drawdown)/Discharge of Liquid) to evaluate the Radius of Influence, The Radius of Influence given Confined Aquifer Discharge with Base 10 is defined as the value of radius of influence when we have prior information of other parameters used. Radius of Influence is denoted by Rw symbol.

How to evaluate Radius of Influence given Confined Aquifer Discharge with Base 10 using this online evaluator? To use this online evaluator for Radius of Influence given Confined Aquifer Discharge with Base 10, enter Radius of Well (r), Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness During Pumping (bp), Total Drawdown (st) & Discharge of Liquid (Qli) and hit the calculate button.

FAQs on Radius of Influence given Confined Aquifer Discharge with Base 10

What is the formula to find Radius of Influence given Confined Aquifer Discharge with Base 10?
The formula of Radius of Influence given Confined Aquifer Discharge with Base 10 is expressed as Radius of Influence = Radius of Well*10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*Total Drawdown)/Discharge of Liquid). Here is an example- 8.139183 = 7.5*10^((2.72*0.1*2.36*0.83)/15).
How to calculate Radius of Influence given Confined Aquifer Discharge with Base 10?
With Radius of Well (r), Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness During Pumping (bp), Total Drawdown (st) & Discharge of Liquid (Qli) we can find Radius of Influence given Confined Aquifer Discharge with Base 10 using the formula - Radius of Influence = Radius of Well*10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*Total Drawdown)/Discharge of Liquid).
What are the other ways to Calculate Radius of Influence?
Here are the different ways to Calculate Radius of Influence-
  • Radius of Influence=Radius of Well*exp((2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*Total Drawdown)/Discharge of Liquid)OpenImg
Can the Radius of Influence given Confined Aquifer Discharge with Base 10 be negative?
No, the Radius of Influence given Confined Aquifer Discharge with Base 10, measured in Length cannot be negative.
Which unit is used to measure Radius of Influence given Confined Aquifer Discharge with Base 10?
Radius of Influence given Confined Aquifer Discharge with Base 10 is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Radius of Influence given Confined Aquifer Discharge with Base 10 can be measured.
Copied!